A generic approach for the detection of whole Listeria monocytogenes cells in contaminated samples using surface plasmon resonance

被引:114
|
作者
Leonard, P
Hearty, S
Quinn, J
O'Kennedy, R [1 ]
机构
[1] Dublin City Univ, Sch Biotechnol, Dublin 9, Ireland
[2] Dublin City Univ, NCSR, Dublin 9, Ireland
来源
BIOSENSORS & BIOELECTRONICS | 2004年 / 19卷 / 10期
关键词
surface plasmon resonance (SPR); subtractive inhibition assay; Listeria monocytogenes;
D O I
10.1016/j.bios.2003.11.009
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The opportunistic food pathogen Listeria monocytogenes is of great concern to the food industry and its rapid detection is of major importance. This paper describes the detection of L. monocytogenes with a polyclonal antibody by means of a new subtractive inhibition assay using a BIAcore 3000 biosensor. Incubating L. monocytogenes cells and antibody for a short period of time, followed by subsequent separation of free unbound antibody with a stepwise centrifugation process, allowed the detection of 1 X 10(5) L. monocytogenes cells/ml in less than 30 ruin. Free antibody was passed over an anti-Fab ligand-coated sensor chip surface with the generated response being inversely proportional to the inhibiting cell concentration. The method was simple, rapid and needed minimum sample preparation. This assay format has the potential for the quick and sensitive detection of pathogens with limited sample handling and preparation. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:1331 / 1335
页数:5
相关论文
共 50 条
  • [41] Precise detection and signature of biological/chemical samples based on surface plasmon resonance (SPR)
    Bera M.
    Ray M.
    Journal of Optics, 2009, 38 (4) : 232 - 248
  • [42] Target cells capture and detection based on a surface plasmon resonance biosensor
    Chen, X.
    Zhang, L. L.
    Cui, D. F.
    Ge, S.
    Zhang, J.
    Qiu, X.
    MICRO & NANO LETTERS, 2015, 10 (09): : 452 - 455
  • [43] Surface plasmon resonance based photonic crystal fiber sensor for bio samples detection
    Meshginqalam, Bahar
    Barvestani, Jamal
    EUROPEAN PHYSICAL JOURNAL PLUS, 2024, 139 (07):
  • [44] Rapid detection of Listeria monocytogenes in ham samples using immunomagnetic separation followed by polymerase chain reaction
    Hudson, JA
    Lake, RJ
    Savill, MG
    Scholes, P
    McCormick, RE
    JOURNAL OF APPLIED MICROBIOLOGY, 2001, 90 (04) : 614 - 621
  • [45] Detection of low levels of Listeria monocytogenes cells by using a fiber-optic immunosensor
    Geng, T
    Morgan, MT
    Bhunia, AK
    APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2004, 70 (10) : 6138 - 6146
  • [46] Liquid Crystal Purity Detection Using Surface Plasmon Resonance Phenomena
    Sharma, Vaibhav
    Sinha, Aloka
    PLASMONICS, 2024, 20 (2) : 639 - 655
  • [47] DETECTION OF LOWER HYDROCARBONS USING SURFACE-PLASMON RESONANCE SENSORS
    NAMIRA, E
    ARAKAWA, T
    DENKI KAGAKU, 1994, 62 (08): : 715 - 716
  • [48] Detection of Ralstonia solanacearum using portable surface plasmon resonance technology
    Zhao, L.
    Levy, L.
    Di, R.
    PHYTOPATHOLOGY, 2013, 103 (06) : 167 - 168
  • [50] Detection of catecholamine metabolite in urine using surface plasmon resonance sensor
    Onodera T.
    Eda T.
    Sonoda H.
    Matsui T.
    Toko K.
    IEEJ Transactions on Sensors and Micromachines, 2019, 139 (09) : 278 - 282