The influence of cracks on chloride-induced corrosion of steel in ordinary Portland cement and high performance concretes subjected to different loading conditions

被引:88
|
作者
Jaffer, S. J. [1 ]
Hansson, C. M. [1 ]
机构
[1] Univ Waterloo, Dept Mech & Mechatron Engn, Waterloo, ON N2L 3G1, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Cracked reinforced concrete; Polarization; Pitting corrosion;
D O I
10.1016/j.corsci.2008.09.018
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Many reinforced concrete structures are subjected to variable loads, but little information is available on the effect of such loading, and the accompanying opening and closing of cracks, on the initiation and propagation of chloride-induced rebar corrosion. The purpose of this paper is to provide that information for reinforced ordinary Portland cement concrete and high performance concrete exposed to static or cyclic three-point bending and exposed to salt solution. It was observed that: (i) corrosion occurred only at intersections of the rebar with cracks in the concrete: (ii) high performance concrete was more protective than ordinary Portland cement concrete and (iii) the type of loading had less impact on corrosion than the type of concrete and exposure conditions. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3343 / 3355
页数:13
相关论文
共 50 条
  • [21] Influence of microsilica on protection from chloride-induced corrosion of reinforcing steel
    Hussain, S.Ehtesham
    Rasheeduzzafar
    Journal of Materials in Civil Engineering, 1993, 5 (02): : 155 - 169
  • [22] FORMATION, DEVELOPMENT AND GROWTH OF CRACKS IN CHLORIDE-INDUCED STRESS-CORROSION CRACKING OF HIGH-ALLOY STEEL
    BEYER, C
    SPECKHARDT, H
    MATERIALWISSENSCHAFT UND WERKSTOFFTECHNIK, 1989, 20 (07) : 220 - 226
  • [23] Monitoring corrosion rate for ordinary portland concrete (OPC) and high-performance concrete (HPC) specimens subjected to chloride attack
    Ismail, ME
    Soleymani, HR
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 2002, 29 (06) : 863 - 874
  • [24] Influence of graphene nanoplatelets on the passivation and corrosion resistance of carbon steel bars in ordinary portland cement mortar
    Shakouri, Mahmoud
    Abraham, Ojo Friday
    CONSTRUCTION AND BUILDING MATERIALS, 2024, 452
  • [25] Influence of Sulfates on Chloride Diffusion and Chloride-Induced Reinforcement Corrosion in Limestone Cement Materials at Low Temperature
    Sotiriadis, Konstantinos
    Rakanta, Eleni
    Mitzithra, Maria Eleni
    Batis, George
    Tsivilis, Sotirios
    JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2017, 29 (08)
  • [26] Fatigue Behavior of High-Performance Steel Beams Subjected to Different Corrosion Conditions
    Chai, Ying
    Peng, Jianxin
    Xiao, Linfa
    Liu, Xinhua
    Zhang, Jianren
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2023, 23 (04) : 1105 - 1118
  • [27] Fatigue Behavior of High-Performance Steel Beams Subjected to Different Corrosion Conditions
    Ying Chai
    Jianxin Peng
    Linfa Xiao
    Xinhua Liu
    Jianren Zhang
    International Journal of Steel Structures, 2023, 23 : 1105 - 1118
  • [28] Chloride-induced corrosion of steel reinforcement - Mechanical performance and pit depth analysis
    Apostolopoulos, Charis A.
    Demis, Sotiris
    Papadakis, Vagelis G.
    CONSTRUCTION AND BUILDING MATERIALS, 2013, 38 : 139 - 146
  • [29] Effectiveness of polymer-modified cement mortar with corrosion inhibitor in preventing chloride-induced steel corrosion in concrete
    Civil Eng. Res. and Planning Dept., Quest Engineer Co., Ltd., Ekinishihon-machi, Kanazawa, 920-0025, Japan
    不详
    1600, 1075-1081 (September 2003):
  • [30] Chloride-induced reinforcing steel corrosion in ternary concretes containing fly ash and untreated sugarcane bagasse ash
    Alberto Franco-Lujan, Victor
    Antonio Maldonado-Garcia, Marco
    Manuel Mendoza-Rangel, Jose
    Montes-Garcia, Pedro
    CONSTRUCTION AND BUILDING MATERIALS, 2019, 198 : 608 - 618