Assessment of inhalation flow patterns of soft mist inhaler co-prescribed with dry powder inhaler using inspiratory flow meter for multi inhalation devices

被引:31
|
作者
Hira, Daiki [1 ,9 ]
Koide, Hiroyoshi [2 ]
Nakamura, Shigemi [3 ]
Okada, Toyoko [3 ]
Ishizeki, Kazunori [3 ]
Yamaguchi, Masafumi [4 ]
Koshiyama, Setsuko [5 ]
Oguma, Tetsuya [6 ]
Ito, Kayoko [7 ]
Funayama, Saori [7 ]
Komase, Yuko [8 ]
Morita, Shin-ya [1 ]
Nishiguchi, Kohshi [2 ]
Nakano, Yasutaka [4 ]
Terada, Tomohiro [1 ]
机构
[1] Shiga Univ Med Sci Hosp, Dept Pharm, Otsu, Shiga, Japan
[2] Kyoto Pharmaceut Univ, Fac Pharmaceut Sci, Dept Clin Pharm, Kyoto, Kyoto, Japan
[3] Hitachi Automot Syst Ltd, Isesaki, Gunma, Japan
[4] Shiga Univ Med Sci, Dept Med, Div Resp Med, Otsu, Shiga, Japan
[5] Kinki Chozai Kadono Sanjo Pharm, Kyoto, Kyoto, Japan
[6] Oguma Family Clin, Kusatsu, Shiga, Japan
[7] Niigata Univ Med & Dent Hosp, Oral Rehabil, Niigata, Niigata, Japan
[8] St Marianna Univ, Yokohama City Seibu Hosp, Sch Med, Dept Resp Internal Med, Yokohama, Kanagawa, Japan
[9] Ritsumeikan Univ, Coll Pharmaceut Sci, Kusatsu, Shiga, Japan
来源
PLOS ONE | 2018年 / 13卷 / 02期
关键词
DRUG-DELIVERY; ELDERLY-PATIENTS; ADMIT SERIES; PERFORMANCE; THERAPY; ASTHMA; RATES; TURBUHALER; DESIGN; ISSUES;
D O I
10.1371/journal.pone.0193082
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The patients' inhalation flow pattern is one of the significant determinants for clinical performance of inhalation therapy. However, the development of inhalation flow meters for various inhalation devices has been unable to keep up with the increasing number of newly launched inhalation devices. In the present study, we developed simple attachment orifices for the inhalation flow pattern monitoring system, which are suitable for all commercial inhalers, and investigated the efficacy of the system on the clinical inhalation instruction for patients co-prescribed dry powder inhaler (DPI) and soft mist inhaler (SMI). First, we constructed simple attachment orifices that were adjusted for 13 commercial inhalers, and examined the correlation between orifice and inhalation device. Second, the inhalation flow patterns (peak inspiratory flow rate, PIFR; inhalation duration time, DT) of patients prescribed a combination of DPI and SMI were monitored before and after inhalation instruction. The inhalation resistance of commercial inhalers are listed in the following order; Twincaps (R) > Handihaler (R) > Swinghaler (R) = Clickhaler (R) > Twisthaler (R) > Turbuhaler (R) > Jenuair (R) > Diskus (R) = Ellipta (R) > Diskhaler (R) > Breezhaler (R) > Respimat (R) = pMDI. The pressure drop via orifice was significantly correlated with that via the commercial inhaler. For the confirmation, all participants achieved the DPI criterion of PIFR. On the other hand, 4 participants (6 clinical visits) of 10 experimented participants could not achieve the essential criterion of DT (> 1.5 sec) for SMI, but all participants improved their duration time after inhalation instruction by pharmacists (P<0.05). In the present study, we successfully developed simple attachment orifice suitable for 13 commercial inhalation devices. These data suggested that our simple attachment orifices for the inhalation flow pattern monitoring system can detect patients with inadequate inhalation patterns via SMI.
引用
收藏
页数:12
相关论文
共 22 条
  • [1] Appropriate use of a dry powder inhaler based on inhalation flow pattern
    Tetsuri Kondo
    Makoto Hibino
    Toshimori Tanigaki
    Stanley M. Cassan
    Sakurako Tajiri
    Kenichro Akazawa
    Journal of Pharmaceutical Health Care and Sciences, 3 (1)
  • [2] EFFECT OF INHALATION FLOW, INHALATION VOLUME AND INHALATION DEVICE CHANGES ON DRY POWDER INHALER TOTAL EMITTED DOSE
    Boshra, Mariane S.
    Almeldien, Ahmed G.
    Eldin, Randa Salah
    Elberry, Ahmed A.
    Abdelwahab, Nada Saed
    Rabea, Hoda
    Abdelrahim, Mohamed
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2017, 30 (03) : 4 - 4
  • [3] Effect of inhalation flow rate on the dosing characteristics of dry powder inhaler (DPI) and metered dose inhaler (MDI) products
    Ross, DL
    Schultz, RK
    JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 1996, 9 (02): : 215 - 226
  • [4] Visualization Of Inhalation Flow Profile And Drug Dispersion From A Dry Powder Inhaler Using A Handy Analyzer
    Kondo, T.
    Tanigaki, T.
    Yokoyama, H.
    Hibino, M.
    Cassan, S. M.
    Tajiri, S.
    Akazawa, K.
    Yamada, Y.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2016, 193
  • [5] Effect of Human Error, Inhalation Flow, and Inhalation Volume on Dose Delivery from Ellipta® Dry-Powder Inhaler
    Saeed, Haitham
    Salem, Heba F.
    Rabea, Hoda
    Abdelrahim, Mohamed E. A.
    JOURNAL OF PHARMACEUTICAL INNOVATION, 2019, 14 (03) : 239 - 244
  • [6] Effect of Human Error, Inhalation Flow, and Inhalation Volume on Dose Delivery from Ellipta® Dry-Powder Inhaler
    Haitham Saeed
    Heba F. Salem
    Hoda Rabea
    Mohamed E. A. Abdelrahim
    Journal of Pharmaceutical Innovation, 2019, 14 : 239 - 244
  • [7] ASSESSMENT OF INHALATION TECHNIQUE USING METERED DOSE INHALER AND DRY POWDER INHALER AMONG ASTHMA PATIENTS: PRE AND POST EDUCATION
    Ismail, Nahlah Elkudssiah
    Ahmad, Sohail
    Aziz, Nur Sabiha
    Fatihah, Tg Nur
    Abu Bakar, Tuan
    Kassim, Khairun Nadia Mohd
    Saina, Nurfaizza
    Ismail, Tuan Umar Tuan
    RESPIROLOGY, 2015, 20 : 20 - 20
  • [8] INHALATION PARAMETERS IN PATIENTS WITH ASTHMA USING ALBUTEROL ELECTRONIC MULTI-DOSE DRY POWDER INHALER
    Farooqui, Nabeel
    Safioti, Guilherme
    Granovsky, Lena
    Reich, Michael
    Li, Thomas
    Hill, Tanisha
    Brown, Randall
    Pleasants, Roy
    De Pietro, Michael
    CHEST, 2020, 158 (04) : 39A - 40A
  • [9] Inhalation Parameters In Patients With Asthma Using Albuterol Electronic Multi-dose Dry Powder Inhaler
    Farooqui, Nabeel
    Safioti, Guilherme
    Granovsky, Lena
    Reich, Michael
    Li, Thomas
    Hill, Tanisha
    Pleasants, Roy
    Depietro, Michael
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2020, 145 (02) : AB212 - AB212
  • [10] Using acoustics to estimate inspiratory flow rate and drug removed from a dry powder inhaler
    Holmes, Martin S.
    Seheult, Jansen
    Geraghty, Colm
    D'Arcy, Shona
    Costello, Richard W.
    Reilly, Richard B.
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 6866 - 6869