High Performance of MWCNTs - Chitosan Modified Glassy Carbon Electrode for Voltammetric Trace Analysis of Cd(II)

被引:11
|
作者
Solis, J. Calvillo [1 ]
Galicia, M. [1 ]
机构
[1] Univ Autonoma Ciudad Juarez, Dept Ciencias Quim Biol, Juarez 32300, CH, Mexico
来源
关键词
Anodic stripping voltammetry; glassy carbon electrode; MWCNTs; Trace analysis; Cd(II); SQUARE-WAVE VOLTAMMETRY; ELECTROCHEMICAL DETERMINATION; NANOTUBES; CADMIUM; NANOPARTICLES; COMPOSITE; SENSOR;
D O I
10.20964/2020.07.56
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A scaffold of multiwalled carbon nanotubes (MWCNT) and chitosan biopolymer were assembled on glassy carbon electrode (GCE) for Cadmium(II) ion detection in aqueous solution. The electrodes were characterized using cyclic voltammetry and electrochemical impedance spectroscopy. Parameters for the electrochemical detection of cadmium ions were optimized using Square Wave Anodic Stripping Voltammetry (SWASV), with an acetate buffer at a pH of 5. A limit of detection of 0.09 mu g L-1 was achieved. Moreover, detection selectivity was demonstrated using SWASV with this modified electrode for Cd(II) detection in the presence of other toxic heavy metal ions, including 30 mu g L-1 Pb(II), 30 mu g L-1 Co-1(II), and 100 mu s L-1 Hg(II). This electrode combined with SWASV provides a new perspective for simultaneous detection of these species with a very low limit of detection.
引用
收藏
页码:6815 / 6828
页数:14
相关论文
共 50 条
  • [21] Cyclic voltammetric investigation of Eu3+ on a MWCNTs/SDS-modified glassy carbon (GC) electrode
    Keqiang Ding
    Wenyan Cai
    Qingfei Wang
    Russian Journal of Electrochemistry, 2010, 46 : 180 - 187
  • [22] Cyclic Voltammetric Investigation of Eu3+ on a MWCNTs/SDS-Modified Glassy Carbon (GC) Electrode
    Ding, Keqiang
    Cai, Wenyan
    Wang, Qingfei
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2010, 46 (02) : 180 - 187
  • [23] Voltammetric studies of spinach ferredoxin on a glassy carbon electrode modified with Cobalt(II) tetrasulfophthalocyanine
    Limson, J
    Nyokong, T
    ELECTROANALYSIS, 1998, 10 (14) : 988 - 993
  • [24] Stripping voltammetric analysis of dicofol on graphene-modified glassy carbon electrode
    Kocak, Berna
    Er, Engin
    Celikkan, Huseyin
    IONICS, 2015, 21 (08) : 2337 - 2344
  • [25] Stripping voltammetric analysis of dicofol on graphene-modified glassy carbon electrode
    Berna Koçak
    Engin Er
    Hüseyin Çelikkan
    Ionics, 2015, 21 : 2337 - 2344
  • [26] VOLTAMMETRIC DETERMINATION OF RUPATADINE AT GRAPHENE MODIFIED GLASSY CARBON ELECTRODE
    Devnani, H.
    Singh, P.
    Saxena, S.
    Satsangee, S. P.
    INTERNATIONAL JOURNAL OF PHARMACEUTICAL SCIENCES AND RESEARCH, 2014, 5 (11):
  • [27] Voltammetric Determination of Nitrite Using Modified Glassy Carbon Electrode
    Beigmoradi, Fariba
    Beitollahi, Hadi
    SURFACE ENGINEERING AND APPLIED ELECTROCHEMISTRY, 2024, 60 (01) : 15 - 23
  • [28] Voltammetric Determination of Nitrite Using Modified Glassy Carbon Electrode
    Surface Engineering and Applied Electrochemistry, 2024, 60 : 15 - 23
  • [29] Voltammetric Determination of Bergenin with Graphene Modified Glassy Carbon Electrode
    Li, Xiaobao
    Zou, Ruyi
    Niu, Yanyan
    Shao, Taiming
    Chen, Yong
    Sun, Wei
    He, Mengxiong
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (02): : 1976 - 1984
  • [30] Electrochemical redox of Cd(II) mediated by activated carbon modified glassy carbon electrode
    Tan, W. T.
    Radhi, M. M.
    Abrahman, M. Z.
    Kassim, A.
    ORIENTAL JOURNAL OF CHEMISTRY, 2010, 26 (02) : 339 - 347