A multilevel PWM strategy suitable for high-voltage motor direct drive systems with consideration of the adverse effect of dead time

被引:0
|
作者
Tadano, Yugo
Urushibata, Shota
Ogura, Kazuya
Shigaki, Akira
Nomura, Masakatsu
机构
[1] Central Research Laboratory, R and D Center, Meidensha Corporation
[2] Meidensha, Technology Development Department
[3] Meidensha, System Device Factory Design Department
关键词
multicarrier PWM; high-voltage direct drive inverter; cascaded multilevel inverter; dead time; phase shift;
D O I
10.1002/eej.20474
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Recently, high-voltage motor direct drive systems have been put to practical use, and various multilevel PWM strategies have also been proposed. This paper describes a multilevel PWM strategy [our group calls it the Carrier Phase Selection Method (CPS)] that has the lowest line voltage harmonic distortion in order to prevent the degradation of high-voltage motor winding insulations. This method takes the adverse effect of dead time into consideration, and it controls the shift direction of a carrier phase. Therefore, a favorable output waveform without instantaneous voltage surges is achieved even if the line voltage level changes. Moreover, the swithching transitions across all switching devices are well-balanced, so the utilization of inverter unit cells is equalized. This is an important factor when designing the entire system. Based on simulation and experimental results, it is shown that this CPS method is particularly effective in high-voltage motor direct drive systems. (C) 2008 Wiley Periodicals, Inc.
引用
收藏
页码:77 / 88
页数:12
相关论文
共 34 条
  • [21] An implementation method for the supervisory control of time-driven systems applied to high-voltage direct current transmission grids
    Romero-Rodriguez, Miguel
    Delpoux, Romain
    Pietrac, Laurent
    Dai, Jing
    Benchaib, Abdelkrim
    Niel, Eric
    CONTROL ENGINEERING PRACTICE, 2019, 82 : 97 - 107
  • [22] Enhanced thermal management by direct water spray of high-voltage, high power devices in a three-phase, 18-hp AC motor drive demonstration
    Shaw, MC
    Waldrop, JR
    Chandrasekaran, S
    Kagalwala, B
    Jing, X
    Brown, ER
    Dhir, VJ
    Fabbeo, M
    ITHERM 2002: EIGHTH INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS, PROCEEDINGS, 2002, : 1007 - 1014
  • [23] Control-Induced Time-Scale Separation for Multiterminal High-Voltage Direct Current Systems Using Droop Control
    Chen, Yijing
    Jimenez Carrizosa, Miguel
    Damm, Gilney
    Lamnabhi-Lagarrigue, Francoise
    Li, Ming
    Li, Yan
    IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, 2020, 28 (03) : 967 - 983
  • [24] Semi-hot redundant control method for modular multilevel converter-based high-voltage direct current systems under submodules fault
    Yang, Lixia
    Jia, Lixin
    Zou, Yabin
    Zhang, Mingcan
    Yang, Haoxiang
    IET POWER ELECTRONICS, 2023, 16 (08) : 1367 - 1381
  • [25] Fast optimum-predictive control and capacitor voltage balancing strategy for bipolar back-to-back NPC converters in high-voltage direct current transmission systems
    Chaves, M.
    Margato, E.
    Silva, J. F.
    Pinto, S. F.
    Santana, J.
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2011, 5 (03) : 368 - 375
  • [26] CONSIDERATION OF SKIN EFFECT IN HIGH-VOLTAGE COAXIAL SYSTEMS UNDER TRANSIENT AND STEADY-STATE CONDITIONS, AND ITS IMPACT ON STEEP TRAVELING WAVES
    JANDRELL, IR
    REYNDERS, JP
    IEE PROCEEDINGS-C GENERATION TRANSMISSION AND DISTRIBUTION, 1991, 138 (05) : 445 - 451
  • [27] A Novel Direct Torque Control Strategy of Two-Level Voltage Source Inverters for Eliminating Common-Mode Voltage Spikes Caused by Dead-Time Effect
    Deng, Weitao
    Zhang, Xiuyun
    Xie, Wenwu
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2023, 38 (02) : 2275 - 2284
  • [28] Studies on the effect of high-voltage electric currents on the individual organ systems in animal bodies. I The effect of the direct current on the cardiovascular system of dogs and rabbits
    Jellinek, S
    ARCHIV FUR DIE GESAMTE PHYSIOLOGIE DES MENSCHEN UND DER TIERE, 1908, 124 (6-8): : 271 - 312
  • [29] Effect of high-voltage direct current link on small signal stability of a power system with different penetration level of doubly fed induction generator and direct drive synchronous generator based wind farms
    Kunwar, A.
    Bansal, R. C.
    INTERNATIONAL JOURNAL OF GREEN ENERGY, 2016, 13 (04) : 335 - 343
  • [30] An Improved Prevention Strategy Based on Fault Probability Detection for Commutation Failure in Line-Commutated Converter-Based High-Voltage Direct Current Transmission Systems
    Xu, Ying
    Zou, Yi
    Liu, Lei
    Li, Xiaopeng
    Teng, Yufei
    Gao, Zijian
    ELECTRONICS, 2024, 13 (19)