Effects of Aging on Left Atrial Function Assessed by Two-Dimensional Speckle Tracking Echocardiography

被引:109
|
作者
Okamatsu, Kyoko
Takeuchi, Masaaki [1 ]
Nakai, Hiromi
Nishikage, Tomoko [2 ]
Salgo, Ivan S. [3 ]
Husson, Stephane [3 ]
Otsuji, Yutaka
Lang, Roberto M. [4 ]
机构
[1] Univ Occupat & Environm Hlth, Sch Med, Dept Internal Med 2, Yahatanishi Ku, Kitakyushu, Fukuoka 8078555, Japan
[2] Tane Gen Hosp, Osaka, Japan
[3] Philips Med Syst, Andover, MA USA
[4] Univ Chicago, Med Ctr, Chicago, IL 60637 USA
关键词
Echocardiography; LA volume; LA function; 2D speckle tracking; ACOUSTIC QUANTIFICATION; REAL-TIME; CLINICAL-APPLICATIONS; COMPUTED-TOMOGRAPHY; VENTRICULAR VOLUME; SIZE; STRAIN; PERFORMANCE; VALIDATION; RESERVOIR;
D O I
10.1016/j.echo.2008.11.006
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Aging affects left atrial (LA) function, which can be assessed by two-dimensional (2D) speckle tracking echocardiography (STE). The aim of this study was to determine (1) the feasibility and accuracy of measuring LA volume with 2DSTE and (2) the effects of aging on LA function. Methods: 2DSTE of the LA was acquired from the apical 4-chamber view (frame rate: 63 +/- 11 /sec, iE33) using prototype speckle tracking software (QLAB, Philips Medical Systems, Andover, MA) in 140 healthy volunteers (3-79 years, 74 men). LA wall was tracked on a frame-by-frame basis, and LA volume waveforms were generated. Maximum LA volume (LAVmax) and minimal LA volume (LAVmin), and the LA volume before atrial contraction (LAVpre-a) were measured. Passive emptying percent of total emptying (LA conduit function) and active emptying percent of total emptying (booster function) were calculated as ([LAVmax-LAVpre-a]/[LAVmax-LAVmin]) X 100 and ([LAVa-LAVmin]/[LAVmax-LAVmin]) X 100. Results: Adequate LA volume waveforms were obtained in all subjects. A good correlation was obtained between speckle tracking-derived LA volume measurements and manually traced LA volume measurements of the identical 2D image (LAVmax: r = 0.93, P < .001, LAVmin: r = 0.88, P < .001, LAVpre-a: r = 0.92, P < .001). Passive and active emptying indices had a significant age dependency (r = 0.80, P < .001). Overall, passive emptying accounted for 67% of the total LA emptying ranging from 83% in the youngest to 42% in the oldest decade. Conclusion: Aging significantly affects LA conduit and booster function. 2DSTE can effectively and easily measure LA volume and has a potential for the noninvasive assessment of LA function. (J Am Soc Echocardiogr 2009; 22: 70-75.)
引用
收藏
页码:70 / 75
页数:6
相关论文
共 50 条
  • [21] Evaluation of the left atrial function by two-dimensional speckle-tracking echocardiography in diabetic patients with obesity
    Mohseni-Badalabadi, Reza
    Mehrabi-Pari, Samira
    Hosseinsabet, Ali
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2020, 36 (04): : 643 - 652
  • [22] The effect of cardiac resynchronization therapy on left ventricular diastolic function: assessed by two-dimensional speckle tracking echocardiography
    Lan, Tingyu
    Wang, Hao
    Sun, Xin
    CARDIOLOGY, 2014, 129 : 118 - 118
  • [23] Two-dimensional speckle tracking echocardiography and three-dimensional echocardiography characterization of left atrial giant myxoma
    Cacciapuoti, Fulvio
    Magro, Valerio Massimo
    Caturano, Michele
    Cacciapuoti, Federico
    JOURNAL OF CARDIOVASCULAR ECHOGRAPHY, 2016, 26 (02) : 68 - 70
  • [24] PRE-DIALYSIS LEFT ATRIAL FUNCTION ASSESSED BY TWO-DIMENSIONAL SPECKLE TRACKING ECHOCARDIOGRAPHY AS A PREDICTOR OF UPCOMING HEART FAILURE IN HEMODIALYSIS PATIENTS
    Kim, Minah
    Hyukjin, Park
    Kim, Chang Seong
    Bae, Eun Hui
    Ma, Seong Kwon
    Kim, Soo Wan
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2019, 34
  • [25] Pre-dialysis left atrial function assessed by two-dimensional speckle tracking echocardiography as a predictor of upcoming heart failure in hemodialysis patients
    Park, H.
    Kim, M.
    Jeong, H. K.
    Kim, K. H.
    Cho, J. Y.
    Yoon, H. J.
    Park, J. C.
    EUROPEAN HEART JOURNAL, 2019, 40 : 831 - 831
  • [26] LEFT ATRIAL STRUCTURE AND FUNCTION IN HYPERTENSIVE PATIENTS ASSESSED BY REAL-TIME THREE-DIMENSIONAL SPECKLE TRACKING ECHOCARDIOGRAPHY: A COMPARATIVE STUDY WITH NORMAL SUBJECTS AND TWO-DIMENSIONAL SPECKLE TRACKING
    Iwama, Makoto
    Tanaka, Ryuhei
    Onishi, Noriyuki
    Nagaya, Maki
    Minatoguchi, Shingo
    Abe, Shintaro
    Matsuoka, Reiko
    Goto, Yoshiaki
    Fujii, Tomoko
    Kojima, Tai
    Hirose, Takeshi
    Ono, Koji
    Tanihata, Shintaro
    Iida, Mami
    Noda, Toshiyuki
    Watanabe, Sachiro
    Watanabe, Takatomo
    Kawasaki, Masanori
    Minatoguchi, Shinya
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (13) : E1109 - E1109
  • [27] Evaluation of left atrial function in patients with iron-deficiency anemia by two-dimensional speckle tracking echocardiography
    Shen, Jiaqi
    Zhou, Qiao
    Liu, Yue
    Luo, Runlan
    Tan, Bijun
    Li, Guangsen
    CARDIOVASCULAR ULTRASOUND, 2016, 14
  • [28] LEFT ATRIUM FUNCTION IN PATIENTS WITH PAROXYSMAL ATRIAL FIBRILLATION: ANALYSIS FROM TWO-DIMENSIONAL SPECKLE TRACKING ECHOCARDIOGRAPHY
    Fu Huaying
    Zhou Changyu
    Li Guangping
    Liu Tong
    Zhen Chenghuan
    HEART, 2010, 96 : A170 - A170
  • [29] Evaluation of left atrial function in patients with iron-deficiency anemia by two-dimensional speckle tracking echocardiography
    Jiaqi Shen
    Qiao Zhou
    Yue Liu
    Runlan Luo
    Bijun Tan
    Guangsen Li
    Cardiovascular Ultrasound, 14
  • [30] Left atrium function in patients with paroxysmal atrial fibrillation: analysis from two-dimensional speckle tracking echocardiography
    Fu, H.