STATISTICAL REVIEW OF THE INSULATION CAPACITY OF THE GEIGER-MUELLER COUNTER

被引:17
|
作者
Obrenovic, Marija D. [1 ]
Janicijevic, Aco J. [2 ]
Arbutina, Dalibor S. [3 ]
机构
[1] Univ Belgrade, Fac Elect Engn, Belgrade, Serbia
[2] Univ Belgrade, Fac Technol & Met, Belgrade, Serbia
[3] Univ Belgrade, Fac Mech Engn, Belgrade, Serbia
来源
关键词
Geiger Mueller counter; spontaneous breakdown; gas filtering experiment; BREAKDOWN;
D O I
10.2298/NTRP180913009O
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
This work considers the manifestation of spontaneous breakdowns of Geiger-Mueller counters. This is an experimental type of work. The reasons leading to the spontaneous breakdowns of Geiger-Mueller counters have been analysed under controlled laboratory conditions. The experiments were carried out under the "constant voltage". The tested Geiger-Mueller chambers were commercial chambers of the radial electric field and homogenous electric field. The experimental-statistical methods were used in order to choose the chambers with identical features (with 0.1 % of statistical reliability).The results of experiments showed that the spontaneous breakdown of the Geiger-Mueller counter happens even in the conditions of shielding. They also showed that those breakdowns have cumulative features. The reason for that is a positive feedback between the spontaneous breakdowns. The explanation is confirmed and quantified by the working gas filtering experiments.
引用
收藏
页码:369 / 374
页数:6
相关论文
共 50 条
  • [21] RESOLVING TIME OF GEIGER-MUELLER COUNTERS
    WILLIAMS, DVP
    CALLIHAN, D
    PHYSICAL REVIEW, 1955, 99 (05): : 1626 - 1626
  • [22] Design of a portable dose rate detector based on a double Geiger-Mueller counter
    Wang, Peng
    Tang, Xiao-Bin
    Gong, Pin
    Huang, Xi
    Wen, Liang-Sheng
    Han, Zhen-Yang
    He, Jian-Ping
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 879 : 147 - 152
  • [23] MULTIVIBRATOR QUENCHING OF GEIGER-MUELLER TUBES
    THAMER, BJ
    VOIGT, AF
    PHYSICAL REVIEW, 1948, 74 (09): : 1261 - 1261
  • [24] THE DISCHARGE SPREAD IN GEIGER-MUELLER COUNTERS
    LIEBSON, SH
    PHYSICAL REVIEW, 1948, 74 (06): : 694 - 695
  • [25] MEASUREMENT OF FAST-NEUTRON SENSITIVITIES OF GEIGER-MUELLER COUNTER GAMMA DOSIMETERS
    LEWIS, VE
    YOUNG, DJ
    PHYSICS IN MEDICINE AND BIOLOGY, 1977, 22 (03): : 476 - 480
  • [26] APPLICATION OF AN ELECTRONEGATIVE GAS AS A THIRD COMPONENT OF THE WORKING GAS IN THE GEIGER-MUELLER COUNTER
    Perazic, Luka S.
    Belic, Cedomir I.
    Arbutina, Dalibor S.
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2018, 33 (03): : 268 - 274
  • [27] The discharge mechanism of Geiger-Mueller counters
    Montgomery, CG
    Montgomery, DD
    PHYSICAL REVIEW, 1940, 57 (11): : 1030 - 1040
  • [28] HALOGEN-QUENCHED GEIGER-MUELLER TUBES
    WORSTER, LD
    INSTRUMENTS & CONTROL SYSTEMS, 1971, 44 (10): : 47 - &
  • [29] Concerning the recovery time of Geiger-Mueller counters
    Danforth, WE
    JOURNAL OF THE FRANKLIN INSTITUTE, 1935, 219 : 108 - 110
  • [30] NEW APPARATUS FOR MEASUREMENTS WITH GEIGER-MUELLER COUNTERS
    DENHARTOG, H
    MULLER, FA
    PHYSICA, 1946, 11 (06): : 441 - 446