Noninvasive Arterial Blood Pressure Waveforms in Patients with Continuous-Flow Left Ventricular Assist Devices

被引:23
|
作者
Martina, Jerson R. [1 ]
Westerhof, Berend E. [2 ,3 ]
de Jonge, Nicolaas [4 ]
van Goudoever, Jeroen [3 ]
Westers, Paul [5 ]
Chamuleau, Steven [4 ]
van Dijk, Diederik [6 ]
Rodermans, Ben F. M. [7 ]
de Mol, Bas A. J. M. [8 ]
Lahpor, Jaap R. [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Cardiothorac Surg, NL-3584 CX Utrecht, Netherlands
[2] AMC Ctr Heart Failure Res, Lab Clin Cardiovasc Physiol, Amsterdam, Netherlands
[3] BMEYE BV, Amsterdam, Netherlands
[4] Univ Med Ctr Utrecht, Dept Cardiol, NL-3584 CX Utrecht, Netherlands
[5] Univ Med Ctr Utrecht, Julius Ctr, NL-3584 CX Utrecht, Netherlands
[6] Univ Med Ctr Utrecht, Dept Intens Care, NL-3584 CX Utrecht, Netherlands
[7] Univ Med Ctr Utrecht, Dept Med Technol, NL-3584 CX Utrecht, Netherlands
[8] Univ Amsterdam, Acad Med Ctr, Dept Cardiothorac Surg, NL-1105 AZ Amsterdam, Netherlands
关键词
rotary pump; aortic valve; Nexfin; echocardiography; ADVANCED HEART-FAILURE; SUPPORT; MANAGEMENT;
D O I
10.1097/MAT.0000000000000033
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Arterial blood pressure and echocardiography may provide useful physiological information regarding cardiac support in patients with continuous-flow left ventricular assist devices (cf-LVADs). We investigated the accuracy and characteristics of noninvasive blood pressure during cf-LVAD support. Noninvasive arterial pressure waveforms were recorded with Nexfin (BMEYE, Amsterdam, The Netherlands). First, these measurements were validated simultaneously with invasive arterial pressures in 29 intensive care unit patients. Next, the association between blood pressure responses and measures derived by echocardiography, including left ventricular end-diastolic dimensions (LVEDDs), left ventricular end-systolic dimensions (LVESDs), and left ventricular shortening fraction (LVSF) were determined during pump speed change procedures in 30 outpatients. Noninvasive arterial blood pressure waveforms by the Nexfin monitor slightly underestimated invasive measures during cf-LVAD support. Differences between noninvasive and invasive measures (mean +/- SD) of systolic, diastolic, mean, and pulse pressures were -7.6 +/- 5.8, -7.0 +/- 5.2, -6.9 +/- 5.1, and -0.6 +/- 4.5 mm Hg, respectively (all < 10%). These blood pressure responses did not correlate with LVEDD, LVESD, or LVSF, while LVSF correlated weakly with both pulse pressure (r = 0.24; p = 0.005) and (dP(art)/dt)(max) (r = 0.25; p = 0.004). The dicrotic notch in the pressure waveform was a better predictor of aortic valve opening (area under the curve [AUC] = 0.87) than pulse pressure (AUC = 0.64) and (dP(art)/dt)(max) (AUC = 0.61). Patients with partial support rather than full support at 9,000 rpm had a significant change in systolic pressure, pulse pressure, and (dP(art)/dt)(max) during ramp studies, while echocardiographic measures did not change. Blood pressure measurements by Nexfin were reliable and may thereby act as a compliment to the assessment of the cf-LVAD patient.
引用
收藏
页码:154 / 161
页数:8
相关论文
共 50 条
  • [31] Benefits of Neurohormonal Therapy in Patients With Continuous-Flow Left Ventricular Assist Devices
    Yousefzai, Rayan
    Brambatti, Michela
    Tran, Hao A.
    Pedersen, Rachel
    Braun, Oscar O.
    Baykaner, Tina
    Ghashghaei, Roxana
    Sulemanjee, Nasir Z.
    Cheema, Omar M.
    Rappelt, Matthew
    Baeza, Carmela
    Alkhayyat, Abdulaziz
    Shi, Yang
    Pretorius, Victor
    Greenberg, Barry
    Adler, Eric
    Thohan, Vinay
    ASAIO JOURNAL, 2020, 66 (04) : 409 - 414
  • [32] Hematologic disorders and continuous-flow left ventricular assist devices
    Connors, Jean M.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2014, 33 (11): : 1114 - 1116
  • [33] Factor Xa inhibitors in patients with continuous-flow left ventricular assist devices
    Vishal Y. Parikh
    Umang M. Parikh
    Angel Moctezuma-Ramirez
    Harveen K. Lamba
    Joggy K. George
    Savitri Fedson
    Ajith P. Nair
    O. H.  Frazier
    Reynolds M. Delgado
    General Thoracic and Cardiovascular Surgery, 2020, 68 : 1278 - 1284
  • [34] Transmission of Pulsatility Into the Brain of Patients with Continuous-Flow Left Ventricular Assist Devices
    Stohr, E. J.
    Castagna, F.
    Pinsino, A.
    Cockcroft, J. R.
    Yuzefpolskaya, M.
    Garan, A. R.
    Topkara, V. K.
    Takayama, H.
    Takeda, K.
    Naka, Y.
    Colombo, P. C.
    Willey, J. Z.
    McDonnell, B. J.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2018, 37 (04): : S284 - S284
  • [35] Continuous-flow left ventricular assist devices induce Left ventricular reverse remodeling
    Jacobs, Steven
    Geens, Jef
    Rega, Filip
    Burkhoff, Daniel
    Meyns, Bart
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2013, 32 (04): : 466 - 468
  • [36] Ventricular arrhythmias do not affect prognosis in patients with continuous-flow left ventricular assist devices
    Koenig, T.
    Heimeshoff, J.
    Duncker, D.
    Schmitto, J.
    Veltmann, C.
    EUROPEAN HEART JOURNAL, 2017, 38 : 234 - 234
  • [37] Ventricular reconditioning and pump explantation in patients supported by continuous-flow left ventricular assist devices
    Frazier, O. H.
    Baldwin, Andrew C. W.
    Demirozu, Zumrut T.
    Segura, Ana Maria
    Hernandez, Ruben
    Taegtmeyer, Heinrich
    Mallidi, Hari
    Cohn, William E.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2015, 34 (06): : 766 - 772
  • [38] Catheter Ablation for Ventricular Tachyarrhythmias in Patients Supported by Continuous-Flow Left Ventricular Assist Devices
    Garan, Arthur R.
    Iyer, Vivek
    Whang, William
    Mody, Kanika P.
    Yuzefpolskaya, Melana
    Colombo, Paolo C.
    Te-Frey, Rosie
    Takayama, Hiroo
    Naka, Yoshifumi
    Garan, Hasan
    Jorde, Ulrich P.
    Uriel, Nir
    ASAIO JOURNAL, 2014, 60 (03) : 311 - 316
  • [39] Electrophysiologic Changes and Their Effects on Ventricular Arrhythmias in Patients with Continuous-Flow Left Ventricular Assist Devices
    Celik, Mehmet
    Emiroglu, Mehmet Yunus
    Bayram, Zubeyde
    Izci, Servet
    Karagoz, Ali
    Akbal, Ozgur Yasar
    Kahyaoglu, Muzaffer
    Kup, Ayhan
    Yilmaz, Yusuf
    Kirali, Mehmet Kaan
    Ozdemir, Nihal
    ASAIO JOURNAL, 2022, 68 (03) : 341 - 348
  • [40] Interpretation of blood pressure (BP) values using noninvasive blood pressure measurement in patients with continuous-flow left ventricular assist device (LVAD) - clinical problem
    Lazarova, M. Marie
    Kara, T.
    Aiglova, R.
    Stritecky, J.
    Nemec, P.
    Taborsky, M.
    EUROPEAN JOURNAL OF HEART FAILURE, 2019, 21 : 580 - 581