Fabrication of polyaniline-HCl cladding modified fiber optic intrinsic biosensor for glucose detection

被引:1
|
作者
Pahurkar, Vikas [1 ]
Tamgadge, Yuoraj [2 ]
Muley, Gajanan [1 ]
机构
[1] Sant Gadge Baba Amravati Univ, Dept Phys, Amravati 444602, Maharashtra, India
[2] Mahatma Fule Mahavidyalaya, Dept Phys, Amravati 444906, Maharashtra, India
关键词
D O I
10.1063/1.4946483
中图分类号
O59 [应用物理学];
学科分类号
摘要
In the present study, we have fabricated and studied response of cladding modified fiber optic intrinsic glucose biosensor (FOIGB). The optical fiber was used as a light transforming waveguide and sensing element fabricated over it by applying a thin layer of polymer. The cladding of the sensor was modified with the polyaniline-hydrochloric acid (PANI-HCl) polymer matrix. The PANI-HCl matrix provides an amorphous morphology useful to immobilize glucose oxidase (GOx) biomolecules through cross-linking technique via glutaraldehyde. The present sensor was used to detect the glucose analyte in the solution. In the sensing response study of FOIGB toward glucose, novel modal power distribution (MPD) technique was used. The reaction between GOx and glucose changes the optical properties of prepared FOIGB and hence modify MPD at output as a function of glucose concentration. The nature and surface morphology of PANI-HCl matrix has been studied.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Clad-modified fiber optic sensor utilizing CdS nanoflower as cladding for the detection of ethanol
    Narasimman, S.
    Balakrishnan, L.
    Alex, Z. C.
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN ELECTRONICS, 2021, 32 (19) : 23900 - 23910
  • [22] Fiber optic chemical sensor with modified cladding refractive index
    Bao, HY
    Wang, TY
    PASSIVE COMPONENTS AND FIBER-BASED DEVICES II, PT 1 AND 2, 2005, 6019 : U387 - U391
  • [23] MODIFIED CLADDING WAVELENGTH DEPENDENT FIBER OPTIC TEMPERATURE SENSOR
    KOPERA, PM
    MELINGER, J
    TEKIPPE, VJ
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1983, 412 : 82 - 89
  • [24] A novel fiber optic glucose biosensor based on fluorescence quenching
    Jiang, DS
    Liu, E
    Huang, J
    ADVANCED SENSOR SYSTEMS AND APPLICATIONS, 2002, 4920 : 205 - 212
  • [25] Graphene patterned polyaniline-based biosensor for glucose detection
    Nguyen, Hai Binh
    Nguyen, Van Chuc
    Nguyen, Van Tu
    Tam Ngo, Thi Thanh
    Nguyen, Ngoc Thinh
    Huyen Dang, Thi Thu
    Tran, Dai Lam
    Do, Phuc Quan
    Nguyen, Xuan Nghia
    Nguyen, Xuan Phuc
    Phan, Hong Khoi
    Phan, Ngoc Minh
    Advances in Natural Sciences: Nanoscience and Nanotechnology, 2012, 3 (02)
  • [26] Surface plasmon resonance based fiber optic glucose biosensor
    Srivastava, Sachin K.
    Verma, Roli
    Gupta, Banshi D.
    THIRD ASIA PACIFIC OPTICAL SENSORS CONFERENCE, 2012, 8351
  • [27] Dual cladding configuration for the fabrication of fiber-optic sensors.
    Hoyt, AE
    Harrah, LA
    Coons, NC
    Powers, TM
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1999, 218 : U565 - U565
  • [28] Bienzymatic glucose biosensor based on graphite electrode modified with nanofibrous polyaniline
    Guo Xiao-Li
    Guo Min
    Wang Xin-Dong
    ACTA PHYSICO-CHIMICA SINICA, 2007, 23 (04) : 585 - 589
  • [29] Portable multichannel fiber optic biosensor for field detection
    Golden, JP
    Saaski, EW
    ShriverLake, LC
    Anderson, GP
    Ligler, FS
    OPTICAL ENGINEERING, 1997, 36 (04) : 1008 - 1013
  • [30] FIBER OPTIC BIOSENSOR FOR FLUOROMETRIC DETECTION OF DNA HYBRIDIZATION
    PIUNNO, PAE
    KRULL, UJ
    HUDSON, RHE
    DAMHA, MJ
    COHEN, H
    ANALYTICA CHIMICA ACTA, 1994, 288 (03) : 205 - 214