Simulation of double-stage double-effect metal hydride heat pump

被引:17
|
作者
Satheesh, A. [1 ]
Muthukumar, P. [1 ]
机构
[1] Indian Inst Technol Guwahati, Dept Mech Engn, Gauhati 781039, India
关键词
Metal hydride; Double-stage double-effect heat pump; Coupled heat and mass transfer; THERMODYNAMIC ANALYSIS; COOLING SYSTEM; MASS-TRANSFER; TRANSFORMER; PERFORMANCE; ALLOYS;
D O I
10.1016/j.ijhydene.2009.12.027
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
This paper presents the operational characteristics of a double-stage double-effect metal hydride heat pump (DSDE-MHHP) working with LaNi4.1Al0.52Mn0.38/LmNi(4.91)Sn(0.15)/ Ti0.99Zr0.01V0.43Fe0.09Cr0.05Mn1.5 as high/medium/low temperature alloys. The performances of the DSDE-MHHP are predicted by solving the transient, two-dimensional, conjugate heat and mass transfer characteristics between the paired metal hydride reactors of cylindrical configuration using the finite volume method (FVM). The designed operating temperatures chosen for the present analysis are S68, 361, 296, and 289 K as heat driven (T-D), heat rejection (T-H), heat sink (T-M) and refrigeration (T-C) temperatures, respectively. The variations in hydrogen concentrations, hydride equilibrium pressures, and temperatures within the hydride beds, and the heat exchange between the hydride beds with the heat transfer fluids are presented for a complete cycle. The operating cycle of a DSDE-MHHP is explained on dynamic pressure-concentration-temperature (PCT) plot. The variation of temperatures in the reactors during hydriding and dehydriding processes is compared with experimental data and a good agreement was observed between them. For given operating temperatures of 568/361/296/289 K, the average coefficient of performance (COP) and the specific cooling power (SCP) of the system are found to be 0.471 and 28.4W/kg of total hydride mass, respectively. (C) 2009 Professor T. Nejat Veziroglu. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1474 / 1484
页数:11
相关论文
共 50 条
  • [31] AN AUTOMATIC DOUBLE-STAGE WATER STILL
    HAMILTON, JA
    PILLIG, RA
    AMERICAN LABORATORY, 1987, 19 (01) : 24 - &
  • [32] Analysis of a double-stage magnetic multiplicator
    P. A. Dergachev
    V. P. Kiryukhin
    Yu. V. Kulaev
    P. A. Kurbatov
    O. N. Molokanov
    Russian Electrical Engineering, 2012, 83 (5) : 271 - 277
  • [33] Simulation Model for Dynamic Operation of Double-Effect Absorption Chillers
    Ahmed, Mojahid Sid Ahmed Mohammed Salih
    Gilani, Syed Ihtsham Ul-Haq
    ICPER 2014 - 4TH INTERNATIONAL CONFERENCE ON PRODUCTION, ENERGY AND RELIABILITY, 2014, 13
  • [34] KILLING AND THE PRINCIPLE OF DOUBLE-EFFECT
    VANDENBELD, A
    SCOTTISH JOURNAL OF THEOLOGY, 1988, 41 (01) : 93 - 116
  • [35] Crystallization with double-effect evaporation
    Schliephake, D
    Bruhns, M
    Ekelhof, B
    Sittel, G
    Harten, U
    ZUCKERINDUSTRIE, 1996, 121 (04): : 238 - 242
  • [36] Experimental Characterization of a Double-Effect Absorption Heat Pump-MED System Driven by Parabolic Trough Collectors
    Chorak, Aicha
    Palenzuela, Patricia
    Alarcon-Padilla, Diego-Cesar
    Ben Abdellah, Abdellatif
    2018 6TH INTERNATIONAL RENEWABLE AND SUSTAINABLE ENERGY CONFERENCE (IRSEC), 2018, : 665 - 672
  • [37] Reducing process cost and CO2 emissions for extractive distillation by double-effect heat integration and mechanical heat pump
    You, Xinqiang
    Rodriguez-Donis, Ivonne
    Gerbaud, Vincent
    APPLIED ENERGY, 2016, 166 : 128 - 140
  • [39] SIMULATION OF SINGLE-STAGE AND DOUBLE-STAGE RECIPROCATING-COMPRESSOR SYSTEMS WITH ALLOWANCE FOR FRICTIONAL EFFECTS AND HEAT-TRANSFER
    UCER, AS
    BENSON, RS
    ISRAEL JOURNAL OF TECHNOLOGY, 1977, 15 (4-5): : 196 - 208
  • [40] Coarse Particle Motion Characteristics in a Double-Stage Slurry Pump Considering Leakage Flow
    Jia, Hao
    Wang, Yuqi
    Zhu, Zuchao
    Su, Xianghui
    Tang, Zhenji
    SHOCK AND VIBRATION, 2021, 2021