Improving dose delivery accuracy with EPID in vivo dosimetry: results from a multicenter study

被引:19
|
作者
Esposito, M. [1 ]
Piermattei, A. [2 ]
Bresciani, S. [3 ]
Orlandini, L. C. [4 ]
Falco, M. D. [5 ]
Giancaterino, S. [5 ]
Cilla, S. [6 ]
Ianiro, A. [6 ]
Nigro, R. [7 ]
Botez, L. [3 ]
Riccardi, S. [7 ]
Fidanzio, A. [2 ]
Greco, F. [2 ]
Villaggi, E. [8 ]
Russo, S. [9 ]
Stasi, M. [10 ]
机构
[1] Azienda Sanitaria USL Toscana Ctr Florence, Med Phys Unit, SC Fis Sanitaria Firenze Empoli, Radiat Oncol Dept, Via DellAntella 58, I-50012 Florence, Italy
[2] Fdn Policlin Univ A Gemelli IRCCS, Radioterapia Oncol Ematol, UOC Fis Sanitaria, Rome, Italy
[3] Candiolo Canc Inst FPO IRCCS, Med Phys, Turin, Italy
[4] Sichuan Canc Hosp, Dept Radiat Oncol, Chengdu, Peoples R China
[5] Univ G dAnnunzio, Dipartimento Radioterapia, Chieti, Italy
[6] Fdn Ric & Cura Giovanni Paolo II, Med Phys Unit, Campobasso, Italy
[7] OGP S Camillo Lellis, Rieti, Italy
[8] AUSL Piacenza, Piacenza, Italy
[9] Azienda Sanitaria USL Toscana Ctr Florence, SC Fis Sanitaria Firenze Empoli, Florence, Italy
[10] SC Fis Sanitaria, AO Ordine Mauriziano Torino, Turin, Italy
关键词
Error detection; Quality assurance; Portal dosimetry; Online dosimetry; Online measurements;
D O I
10.1007/s00066-021-01749-6
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose To investigate critical aspects and effectiveness of in vivo dosimetry (IVD) tests obtained by an electronic portal imaging device (EPID) in a multicenter and multisystem context. Materials and methods Eight centers with three commercial systems-SoftDiso (SD, Best Medical Italy, Chianciano, Italy), Dosimetry Check (DC, Math Resolution, LCC), and PerFRACTION (PF, Sun Nuclear Corporation, SNC, Melbourne, FL)-collected IVD results for a total of 2002 patients and 32,276 tests. Data are summarized for IVD software, radiotherapy technique, and anatomical site. Every center reported the number of patients and tests analyzed, and the percentage of tests outside of the tolerance level (OTL%). OTL% was categorized as being due to incorrect patient setup, incorrect use of immobilization devices, incorrect dose computation, anatomical variations, and unknown causes. Results The three systems use different approaches and customized alert indices, based on local protocols. For Volumetric Modulated Arc Therapy (VMAT) treatments OTL% mean values were up to 8.9% for SD, 18.0% for DC, and 16.0% for PF. Errors due to "anatomical variations" for head and neck were up to 9.0% for SD and DC and 8.0% for PF systems, while for abdomen and pelvis/prostate treatments were up to 9%, 17.0%, and 9.0% for SD, DC, and PF, respectively. The comparison among techniques gave 3% for Stereotactic Body Radiation Therapy, 7.0% (range 4.7-8.9%) for VMAT, 10.4% (range 7.0-12.2%) for Intensity Modulated Radiation Therapy, and 13.2% (range 8.8-21.0%) for 3D Conformal Radiation Therapy. Conclusion The results obtained with different IVD software and among centers were consistent and showed an acceptable homogeneity. EPID IVD was effective in intercepting important errors.
引用
收藏
页码:633 / 643
页数:11
相关论文
共 50 条
  • [1] Improving dose delivery accuracy with EPID in vivo dosimetry: results from a multicenter study
    M. Esposito
    A. Piermattei
    S. Bresciani
    L. C. Orlandini
    M. D. Falco
    S. Giancaterino
    S. Cilla
    A. Ianiro
    R. Nigro
    L. Botez
    S. Riccardi
    A. Fidanzio
    F. Greco
    E. Villaggi
    S. Russo
    M. Stasi
    Strahlentherapie und Onkologie, 2021, 197 : 633 - 643
  • [2] Improving radiotherapy accuracy with EPID in-vivo dosimetry: results from a multicentric study.
    Esposito, M.
    Piermattei, A.
    Bresciani, S.
    Orlandini, L. C.
    Falco, M. D.
    Giancaterino, S.
    Savino, C.
    Ianiro, A.
    Nigro, R.
    Botez, L.
    Riccardi, S.
    Fidanzio, A.
    Greco, F.
    Villaggi, E.
    Russo, S.
    Stasi, M.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S305 - S305
  • [3] Preliminary results of in-vivo dosimetry by EPID
    Giancaterino, S.
    Falco, M.
    De Nicola, A.
    Adorante, N.
    Di Tommaso, M.
    Trignani, M.
    Allajbej, A.
    Perrotti, F.
    Genovesi, D.
    Greco, F.
    Grusio, M.
    Piermattei, A.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S788 - S789
  • [4] Using EPID in Vivo Dosimetry to Quantify Treatment Delivery Accuracy in Canine Head and Neck Tumors
    Lambeck, J.
    Saad, S.
    Hansen, K.
    Kent, M.
    Dieterich, S.
    MEDICAL PHYSICS, 2019, 46 (06) : E606 - E607
  • [5] Study of Dose Variations Induced by Collimator Rotation for IMRT Delivery Using EPID Dosimetry
    Li, J.
    Burman, C.
    Schupak, K.
    Chan, M. F.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S781 - S782
  • [6] EPID based in vivo dosimetry system: clinical experience and results
    Celi, Sofia
    Costa, Emilie
    Wessels, Claas
    Mazal, Alejandro
    Fourquet, Alain
    Francois, Pascal
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (03): : 262 - 276
  • [7] IN VIVO DOSIMETRY FROM EPID AND MONTE CARLO SIMULATION
    Badel, J. N.
    Ginestet, C.
    Sarrut, D.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S386 - S386
  • [8] Improving the accuracy of dosimetry verification by non-uniform backscatter correction in the EPID
    Radzi, Y. Md
    Windle, R. S.
    Lewis, D. G.
    Spezi, E.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S787 - S787
  • [9] EPID-based in-vivo dosimetry results: a national statistic
    Piermattei, A.
    Menna, S.
    Greco, F.
    Cilla, S.
    Caivano, R.
    Fusco, V.
    Orlandini, L.
    Benecchi, G.
    Nigro, R.
    Falco, D.
    Fidanzio, A.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S167 - S168
  • [10] Validation of a new formalism for in vivo dosimetry using transit dose measured with EPID
    Francois, P.
    Berger, L.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S309 - S309