Analysis and Simulation of an Absorption Cooling System Using a Latent Heat Storage Tank and a Tempering Valve

被引:6
|
作者
Cerezo, Jesus [1 ]
Lara, Fernando [2 ]
Romero, Rosenberg J. [1 ]
Rodriguez, Antonio [1 ]
机构
[1] Univ Autonoma Estado Morelos, Ctr Invest Ingn & Ciencias Aplicadas, Ave Univ 1001, Cuernavaca 62209, Morelos, Mexico
[2] Univ Autonoma Baja California, Fac Ingn, Blvd Benito Juarez & Calle Normal S-N, Mexicali 21280, Baja California, Mexico
基金
美国国家科学基金会;
关键词
phase change material; absorption cooling system; parabolic trough collector; tempering valve; thermal energy storage; PHASE-CHANGE MATERIALS;
D O I
10.3390/en14051376
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The energy consumption for space cooling is growing faster than for any other end-use in buildings, more than tripling between 1990 and 2016. Energy efficiency is an important topic in the drive to reduce the consumption of electricity, particularly in air conditioning. This paper presents a simulation of an absorption cooling system with a parabolic trough collector under dynamic conditions using TRaNsient SYstem Simulation (TRNSYS) software. The thermal analysis seeks to evaluate a storage tank at three different configurations: (1) sensible heat, (2) latent heat, and (3) latent heat incorporating a tempering valve. The latent heat storage tank is a rectangular heat exchanger using MgCl2 center dot 6H(2)O as the phase change material, programmed in EES software; in addition, water and synthetic organic fluid were analyzed as heating fluids. The process was analyzed while varying the solar collector area from 20 to 40 m(2) and the storage tank volume from 0.25 to 0.75 m(3). The results showed that the solar collector of configuration 1 is unable to satisfy the energy demand. Configuration 2 can satisfy the demand with water and a storage tank volume above 0.50 m(3) and 30 m(2), while configuration 3 can satisfy the demand above 0.50 m(3) and 20 m(2) with water.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Numerical analysis of a latent heat thermal energy storage system
    Fteïti, Mehdi
    Nasrallah, Sassi Ben
    International Journal of Heat and Technology, 2004, 22 (01) : 161 - 164
  • [32] Numerical analysis of latent heat thermal energy storage system
    Vyshak, N. R.
    Jilani, G.
    ENERGY CONVERSION AND MANAGEMENT, 2007, 48 (07) : 2161 - 2168
  • [33] Thermodynamic analysis of an ejector-flash tank-absorption cooling system
    Sirwan, Ranj
    Alghoul, M. A.
    Sopian, K.
    Ali, Yusoff
    APPLIED THERMAL ENGINEERING, 2013, 58 (1-2) : 85 - 97
  • [34] Heat transfer characteristics in latent heat storage system using paraffin wax
    Stella P. Jesumathy
    M. Udayakumar
    S. Suresh
    Journal of Mechanical Science and Technology, 2012, 26 : 959 - 965
  • [35] Heat transfer characteristics in latent heat storage system using paraffin wax
    Jesumathy, Stella P.
    Udayakumar, M.
    Suresh, S.
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2012, 26 (03) : 959 - 965
  • [36] Use of a latent heat thermal energy storage system for cooling a light-weight building: Experimentation and co-simulation
    Rouault, Fabien
    Bruneau, Denis
    Sebastian, Patrick
    Nadeau, Jean-Pierre
    ENERGY AND BUILDINGS, 2016, 127 : 479 - 487
  • [37] The Influence of Cooling System on LNG Storage Tank Filling
    Haddar, Mohamed
    Hammami, Moez
    Baccar, Mounir
    SUSTAINABLE ENERGY-WATER-ENVIRONMENT NEXUS IN DESERTS, 2022, : 477 - 482
  • [38] Experimental and numerical analysis of composite latent heat storage in cooling systems for power electronics
    Helbing, Thomas Bezerra
    Schmitz, Gerhard
    HEAT AND MASS TRANSFER, 2019, 55 (10) : 2949 - 2958
  • [39] Experimental and numerical analysis of composite latent heat storage in cooling systems for power electronics
    Thomas Bezerra Helbing
    Gerhard Schmitz
    Heat and Mass Transfer, 2019, 55 : 2949 - 2958
  • [40] DYNAMIC SIMULATION OF AN AQUA-AMMONIA ABSORPTION COOLING SYSTEM WITH REFRIGERANT STORAGE
    KAUSHIK, SC
    RAO, SK
    KUMARI, R
    ENERGY CONVERSION AND MANAGEMENT, 1991, 32 (03) : 197 - 206