Countercurrent flow limitation in a pressurizer surge line

被引:5
|
作者
Yamamoto, Yasunori [1 ,3 ]
Murase, Michio [1 ]
Tomiyama, Akio [2 ]
机构
[1] Inst Nucl Safety Syst Inc, 64 Sata, Mihama, Fukui 9191205, Japan
[2] Kobe Univ, Nada Ku, 1-1 Rokkodai, Kobe, Hyogo 6578501, Japan
[3] Hokkaido Univ, Kita Ku, North 13 West 8, Sapporo, Hokkaido 0608628, Japan
关键词
Pressurizer surge line; Countercurrent flow limitation; Vertical pipe; GAS-LIQUID FLOW; AIR-WATER; STEAM;
D O I
10.1016/j.nucengdes.2017.11.008
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In order to clarify the characteristics of countercurrent flow limitation (CCFL) in a pressurizer surge line, CCFL in a vertical pipe with a large diameter was evaluated using previous experimental data and a one-region model with an existing correlation of interfacial shear stress. The CCFL is defined by the relationship between the gas and liquid volumetric fluxes under a quasi-steady state after onset of flooding. A correlation for CCFL at the sharp-edged upper end of vertical pipes was constructed and it was compared to CCFL in the slightly inclined pipe. The comparison indicated that the liquid volumetric flux at the sharp-edged upper end was lower than that in a slightly inclined pipe when they have a large diameter such for an actual-scale pressurizer surge line. However, it was found that the liquid volumetric flux in integral experiments ( including a slightly inclined pipe, a vertical elbow, and a vertical pipe) was lower than that in slightly inclined pipes and vertical pipes. Considering system characteristics from experimental data for the pressurizer surge line, it was concluded that the Kutateladze parameter should be applied with the slope of m=0.94 and the constant of CK=1.24 +/- 0.1 for the Wallis type CCFL correlation.
引用
收藏
页码:175 / 182
页数:8
相关论文
共 50 条
  • [21] Stress and fatigue analysis of pressurizer surge line under thermal stratification
    Tang P.
    Liu Z.W.
    Qiao H.W.
    Li P.Z.
    Key Engineering Materials, 2019, 795 : 268 - 275
  • [22] Summarization of countercurrent flow limitation experiment studies
    Peng, Yunkang
    Hedongli Gongcheng/Nuclear Power Engineering, 1993, 14 (06): : 556 - 560
  • [23] An Investigation on the Reduction Schemes of Environmental Fatigue Usage Factor for Pressurizer Surge Line
    Kang, Sun-yeh
    Jo, Won-ho
    Song, Min-sup
    Yoon, Ki-seok
    Choi, Taek-sang
    Yang, Jun-seog
    PROCEEDINGS OF THE ASME PRESSURE VESSELS AND PIPING CONFERENCE, VOL 3: DESIGN AND ANALYSIS, 2012, : 709 - 714
  • [24] Study on Failure Mechanism of Pressurizer Surge Line and Manhole Structure under LOCA
    Yu H.
    Zhao X.
    Fu S.
    Zhu K.
    Hedongli Gongcheng/Nuclear Power Engineering, 2023, 44 (01): : 109 - 117
  • [25] SCALING ANALYSIS OF THE PRESSURIZER SURGE LINE IN NUCLEAR PLANT INTEGRAL TEST FACILITIES
    Deng, Cheng-Cheng
    Chang, Hua-Jian
    Qin, Ben-Ke
    Wang, Han
    Chen, Lian
    PROCEEDINGS OF THE 20TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING AND THE ASME 2012 POWER CONFERENCE - 2012, VOL 3, 2012, : 197 - 204
  • [26] THREE-FIELD COUNTERCURRENT FLOW LIMITATION MODEL
    Lane, Jeffrey W.
    Aumiller, David L., Jr.
    Hochreiter, Lawrence E.
    Cheung, Fan-Bill
    NUCLEAR TECHNOLOGY, 2012, 177 (02) : 176 - 187
  • [27] Countercurrent Flow Limitation in Slightly Inclined Pipes With Elbows
    Murase, Michio
    Kinoshita, Ikuo
    Kusunoki, Takayoshi
    Lucas, Dirk
    Tomiyama, Akio
    JOURNAL OF NUCLEAR ENGINEERING AND RADIATION SCIENCE, 2015, 1 (04):
  • [28] Correlation for countercurrent flow limitation in a PWR hot leg
    Murase, Michio
    Tomiyama, Akio
    Lucas, Dirk
    Kinoshita, Ikuo
    Utanohara, Yoichi
    Yanagi, Chihiro
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2012, 49 (04) : 398 - 407
  • [29] COUNTERCURRENT-FLOW LIMITATION IN INCLINED CHANNELS WITH BENDS
    GHIAASIAAN, SM
    TURK, RE
    ABDELKHALIK, SI
    NUCLEAR ENGINEERING AND DESIGN, 1994, 152 (1-3) : 379 - 388
  • [30] Correlation for countercurrent flow limitation in a PWR hot leg
    Institute of Nuclear Safety System INC., 64 Sata, Mihama-cho, Mikata-gun, Fukui 919-1205, Japan
    不详
    不详
    J Nucl Sci Technol, 1600, 4 (398-407):