High-performance liquid chromatography of methotrexate for environmental monitoring of surface contamination in hospital departments and assessment of occupational exposure

被引:31
|
作者
Floridia, L
Pietropaolo, AM
Tavazzani, M
Rubino, FM
Colombi, A
机构
[1] ICP, CEMOC, Lab Ind Toxicol & Occupat Allergol, I-20141 Milan, Italy
[2] Univ Milan, Clin L Devoto, Dipartimento Med Lavoro, I-20122 Milan, Italy
来源
JOURNAL OF CHROMATOGRAPHY B | 1999年 / 726卷 / 1-2期
关键词
methotrexate;
D O I
10.1016/S0378-4347(98)00561-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In the frame of applicative research in occupational hygiene of hospital workplaces, we investigate hospital indoor contamination as a consequence of the use of antineoplastic drugs (ANDs), with the purpose of assessing exposure of medical and nursing personnel to potentially harmful doses of ANDs, and ultimately of yielding advice on safe operating procedures for manipulation of ANDs in hospitals and in house-care of cancer patients. Among the large number of currently employed ANDs, methotrexate (MTX) has been selected as a tracer of surface contamination, on the basis of its wide use in therapy, its ease of measurement and of its chemical properties relevant to persistence and transport in the indoor environment, MTX is a polyelectrolyte, with a high water, but lower organic solvent solubility, a negligible vapour pressure and a high chemical robustness to environmental stress, thus allowing to measure surface-to-surface carryover (e.g. from spillage or glove fingerprint) and indoor contamination due to aerosol transport (e.g. from syringe manipulation procedures). Monitoring of MTX in environmental samples such as swab washings of surfaces and objects requires an analytical method with characteristics of sensitivity, reproducibility, precision, analytical speed, ease of automation and robustness. We have therefore developed an analytical procedure which employs simple short-column RP-HPLC with UV detection, automated sample injection and a close analogue internal standard for improved precision and solid-phase extraction (SPE) for sample concentration. Our method has proven suitable for detecting traces of MTX on a wide variety of surfaces and objects, with a limit of quantification in the range of 50 mu g/dm(3) for direct injection of unconcentrated washings, corresponding to the possible detection of surface contamination as low as 1 mu g/m(3) and a limit of detection in the range of 10 ng/m(2) for samples as large as 100 dm(3) concentrated by SPE. We present preliminary results from a recent hospital case-study, assessing the contamination level of furniture and equipment in drug preparation areas. Spillage fractions as high as 5% of the employed mass (70-260 mg/day) are measured on the polythene-backed paper disposable hood cover sheet; traces of MTX in the microgram range can also be measured on floor surfaces, furniture and handles, even at a distance from the preparation hoods. (C) 1999 Published by Elsevier Science BN. All rights reserved.
引用
收藏
页码:95 / 103
页数:9
相关论文
共 50 条
  • [31] Application of high-performance liquid chromatography coupled to nuclear magnetic resonance and high-performance liquid chromatography coupled to mass spectrometry to complex environmental samples
    Levsen, K
    Preiss, A
    Codejohann, M
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2000, 19 (01) : 27 - 48
  • [32] ASSESSMENT OF ABNORMAL CREATININE CONCENTRATION BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    PASSEY, RB
    MALUF, KC
    ALLEN, SE
    CLINICAL CHEMISTRY, 1987, 33 (06) : 1009 - 1009
  • [33] CONTAMINATION OF HEPARIN BY HISTAMINE - MEASUREMENT AND CHARACTERIZATION BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND RADIOIMMUNOASSAY
    HERMANN, K
    FRANK, G
    RING, J
    ALLERGY, 1994, 49 (07) : 569 - 572
  • [34] Determination of aflatoxin contamination in olives by immunoaffinity column using high-performance liquid chromatography
    Bircan, C
    JOURNAL OF FOOD QUALITY, 2006, 29 (02) : 126 - 138
  • [35] Determination of Diquat and Paraquat by High Performance Liquid Chromatography in Areas of Environmental Monitoring
    Fitsev, I. M.
    Likhacheva, A. Yu
    Sayfutdinov, A. M.
    Mukharlyamova, A. Z.
    Mokhtarova, S. L.
    Nasybullina, Z. R.
    UCHENYE ZAPISKI KAZANSKOGO UNIVERSITETA-SERIYA ESTESTVENNYE NAUKI, 2021, 163 (01): : 61 - 71
  • [36] High-performance liquid chromatography (HPLC) as a tool for monitoring the fate of fluazinam in soil
    Hakala, Kati P.
    Tuomainen, Paivi M.
    Yli-Halla, Markku J.
    Hartikainen, Helina
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART B-PESTICIDES FOOD CONTAMINANTS AND AGRICULTURAL WASTES, 2014, 49 (07) : 491 - 497
  • [37] High-performance liquid chromatography with ultraviolet detection for therapeutic drug monitoring of everolimus
    Baldelli, S
    Murgia, S
    Merlini, S
    Zenoni, S
    Perico, N
    Remuzzi, G
    Cattaneo, D
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 816 (1-2): : 99 - 105
  • [38] Monitoring of Epidermal Growth Factor Degradation Products by High-Performance Liquid Chromatography
    Kim, Hyunbin
    Seo, Chan
    Ji, Moongi
    Kim, Youngbae
    Kim, Jung Dong
    Jeong, Do Hyeon
    Lee, Wonjae
    Paik, Man-Jeong
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2018, 39 (07): : 864 - 867
  • [39] MONITORING OF MORANTEL LEVELS IN DIGESTIVE CONTENTS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    ALVINERIE, M
    FIORAMONTI, J
    JOURNAL OF VETERINARY PHARMACOLOGY AND THERAPEUTICS, 1986, 9 (04) : 436 - 438
  • [40] Monitoring of bensulfuron-methyl residues in soil by high-performance liquid chromatography
    Salardi, C
    Gigliotti, C
    Brusa, T
    48TH INTERNATIONAL SYMPOSIUM ON CROP PROTECTION, PTS I-IV, 1996, 61 (2A&B,3): : 617 - 620