Lung Motion and Volume Measurement by Dynamic 3D MRI Using a 128-Channel Receiver Coil

被引:28
|
作者
Tokuda, Junichi [1 ,2 ]
Schmitt, Melanie [3 ]
Sun, Yanping [1 ,2 ]
Patz, Samuel [1 ,2 ]
Tang, Yi [1 ,2 ]
Mountford, Carolyn E. [1 ,2 ]
Hata, Nobuhiko [1 ,2 ]
Wald, Lawrence L. [4 ]
Hatabu, Hiroto [1 ,2 ]
机构
[1] Harvard Univ, Sch Med, Boston, MA 02115 USA
[2] Brigham & Womens Hosp, Dept Radiol, Boston, MA 02115 USA
[3] Massachusetts Gen Hosp, Dept Radiol, Athinoula A Martinos Ctr Biomed Imaging, Charlestown, MA USA
[4] Harvard MIT Div Hlth Sci Technol, Cambridge, MA USA
基金
美国国家卫生研究院;
关键词
Lung; magnetic resonance imaging; image segmentation; lung volume measurement; DIAPHRAGMATIC MOTION; RECONSTRUCTION; RADIOTHERAPY; EMPHYSEMA; MECHANICS;
D O I
10.1016/j.acra.2008.07.021
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. The authors present their initial experience using a 3-T whole-body scanner equipped with a 128-channel coil applied to lung motion assessment. Recent improvements in fast magnetic resonance imaging (MRI) technology have enabled several trials of free-breathing three-dimensional (313) imaging of the lung. A large number of image frames necessarily increases the difficulty of image analysis and therefore warrants automatic image processing. However, the intensity homogeneities of images of prior dynamic 3D lung MRI studies have been insufficient to use such methods. In this study, initial data were obtained at 3 T with a 128-channel coil that demonstrate the feasibility of acquiring multiple sets of 3D pulmonary scans during free breathing and that have sufficient quality to be amenable to automatic segmentation. Materials and Methods. Dynamic 3D images of the lungs of two Volunteers were acquired with acquisition times of 0.62 to 0.76 frames/s and an image matrix of 128 X 128, with 24 to 30 slice encodings. The volunteers were instructed to take shallow and deep breaths during the scans. The variation Of lung volume was measured from the segmented images. Results. Dynamic 3D images were successfully acquired for both respiratory conditions for each subject. The images showed whole-lung motion, including lifting of the chest wall and the displacement of the diaphragm, with sufficient contrast to distinguish these structures from adjacent tissues. The average time to complete segmentation for one 3D image was 4.8 seconds. The tidal volume measured was consistent with known tidal volumes for healthy subjects performing deep-breathing maneuvers. The temporal resolution was insufficient to measure tidal volumes for shallow breathing Conclusion. This initial experience with a 3-T whole-body scanner and a 128-channel coil showed that the scanner and imaging protocol provided dynamic 3D images with spatial and temporal resolution sufficient to delineate the diaphragmatic domes and chest wall during active breathing. In addition, the intensity homogeneities and signal-to-noise ratio were adequate to perform automatic segmentation.
引用
收藏
页码:22 / 27
页数:6
相关论文
共 50 条
  • [21] Evaluation of whole lung 3D dynamic oxygen-enhanced MRI
    Ulloa, Jose
    Morgan, Alexandra
    Parker, Geoff
    EUROPEAN RESPIRATORY JOURNAL, 2014, 44
  • [22] Dynamic 3D Measurement without Motion Artifacts Based on Feature Compensation
    Hu, Guoce
    Wang, Jun
    Deng, Huaxia
    Ma, Mengchao
    Zhong, Xiang
    SENSORS, 2023, 23 (16)
  • [23] Motion robust high resolution 3D free-breathing pulmonary MRI using dynamic 3D image self-navigator
    Jiang, Wenwen
    Ong, Frank
    Johnson, Kevin M.
    Nagle, Scott K.
    Hope, Thomas A.
    Lustig, Michael
    Larson, Peder E. Z.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (06) : 2954 - 2967
  • [24] Accuracy of Volume Measurement Using 3D Ultrasound and Fusion of Different Modalities (3D US-CT, 3D US-MRI) for Prostate Cancer Treatment
    Baek, J.
    Chung, K.
    Kim, M.
    An, S.
    Oh, Y.
    Na, T.
    Cho, S.
    Kim, D.
    Lee, R.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [25] Spherical navigator echoes for full 3D rigid body motion measurement in MRI
    Welch, EB
    Manduca, A
    Grimm, RC
    Ward, HA
    Jack, CR
    MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (01) : 32 - 41
  • [26] Semi-automatic segmentation for 3D motion analysis of the tongue with dynamic MRI
    Lee, Junghoon
    Woo, Jonghye
    Xing, Fangxu
    Murano, Emi Z.
    Stone, Maureen
    Prince, Jerry L.
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2014, 38 (08) : 714 - 724
  • [27] SEMI-AUTOMATIC SEGMENTATION OF THE TONGUE FOR 3D MOTION ANALYSIS WITH DYNAMIC MRI
    Lee, Junghoon
    Woo, Jonghye
    Xing, Fangxu
    Murano, Emi Z.
    Stone, Maureen
    Prince, Jerry L.
    2013 IEEE 10TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2013, : 1465 - 1468
  • [28] Tendon moment arm measurement using 3D MRI images
    Zhu, Q
    Duerk, JL
    Mansour, JM
    Crago, PE
    Wilson, DL
    PROCEEDINGS OF THE 19TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 19, PTS 1-6: MAGNIFICENT MILESTONES AND EMERGING OPPORTUNITIES IN MEDICAL ENGINEERING, 1997, 19 : 480 - 482
  • [29] Enhancements in 3D dosimetry measurement using polymer gel and MRI
    Rabaeh, K. A.
    Saion, Elias
    Omer, M.
    Shahrim, Iskandar
    Alrahman, Azhar A.
    Hussain, M.
    RADIATION MEASUREMENTS, 2008, 43 (08) : 1377 - 1382
  • [30] Modular 128-Channel Δ-ΔΣ Analog Front-End Architecture Using Spectrum Equalization Scheme for 1024-Channel 3-D Neural Recording Microsystems
    Park, Sung-Yun
    Cho, Jihyun
    Na, Kyounghwan
    Yoon, Euisik
    IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2018, 53 (02) : 501 - 514