Lung Motion and Volume Measurement by Dynamic 3D MRI Using a 128-Channel Receiver Coil

被引:28
|
作者
Tokuda, Junichi [1 ,2 ]
Schmitt, Melanie [3 ]
Sun, Yanping [1 ,2 ]
Patz, Samuel [1 ,2 ]
Tang, Yi [1 ,2 ]
Mountford, Carolyn E. [1 ,2 ]
Hata, Nobuhiko [1 ,2 ]
Wald, Lawrence L. [4 ]
Hatabu, Hiroto [1 ,2 ]
机构
[1] Harvard Univ, Sch Med, Boston, MA 02115 USA
[2] Brigham & Womens Hosp, Dept Radiol, Boston, MA 02115 USA
[3] Massachusetts Gen Hosp, Dept Radiol, Athinoula A Martinos Ctr Biomed Imaging, Charlestown, MA USA
[4] Harvard MIT Div Hlth Sci Technol, Cambridge, MA USA
基金
美国国家卫生研究院;
关键词
Lung; magnetic resonance imaging; image segmentation; lung volume measurement; DIAPHRAGMATIC MOTION; RECONSTRUCTION; RADIOTHERAPY; EMPHYSEMA; MECHANICS;
D O I
10.1016/j.acra.2008.07.021
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. The authors present their initial experience using a 3-T whole-body scanner equipped with a 128-channel coil applied to lung motion assessment. Recent improvements in fast magnetic resonance imaging (MRI) technology have enabled several trials of free-breathing three-dimensional (313) imaging of the lung. A large number of image frames necessarily increases the difficulty of image analysis and therefore warrants automatic image processing. However, the intensity homogeneities of images of prior dynamic 3D lung MRI studies have been insufficient to use such methods. In this study, initial data were obtained at 3 T with a 128-channel coil that demonstrate the feasibility of acquiring multiple sets of 3D pulmonary scans during free breathing and that have sufficient quality to be amenable to automatic segmentation. Materials and Methods. Dynamic 3D images of the lungs of two Volunteers were acquired with acquisition times of 0.62 to 0.76 frames/s and an image matrix of 128 X 128, with 24 to 30 slice encodings. The volunteers were instructed to take shallow and deep breaths during the scans. The variation Of lung volume was measured from the segmented images. Results. Dynamic 3D images were successfully acquired for both respiratory conditions for each subject. The images showed whole-lung motion, including lifting of the chest wall and the displacement of the diaphragm, with sufficient contrast to distinguish these structures from adjacent tissues. The average time to complete segmentation for one 3D image was 4.8 seconds. The tidal volume measured was consistent with known tidal volumes for healthy subjects performing deep-breathing maneuvers. The temporal resolution was insufficient to measure tidal volumes for shallow breathing Conclusion. This initial experience with a 3-T whole-body scanner and a 128-channel coil showed that the scanner and imaging protocol provided dynamic 3D images with spatial and temporal resolution sufficient to delineate the diaphragmatic domes and chest wall during active breathing. In addition, the intensity homogeneities and signal-to-noise ratio were adequate to perform automatic segmentation.
引用
收藏
页码:22 / 27
页数:6
相关论文
共 50 条
  • [1] 128-Channel Body MRI With a Flexible High-Density Receiver-Coil Array
    Hardy, Christopher J.
    Giaquinto, Randy O.
    Piel, Joseph E.
    Rohling, Kenneth W.
    Marinelli, Luca
    Blezek, Daniel J.
    Fiveland, Eric W.
    Darrow, Robert D.
    Foo, Thomas K. F.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 28 (05) : 1219 - 1225
  • [2] A 128-channel receive-only cardiac coil for highly accelerated cardiac MRI at 3 tesla
    Schmitt, Melanie
    Potthast, Andreas
    Sosnovik, David E.
    Polimeni, Jonathan R.
    Wiggins, Graham C.
    Triantafyllou, Christina
    Wald, Lawrence L.
    MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (06) : 1431 - 1439
  • [3] In room measurement of 3D motion in lung
    Sonke, JJ
    Wolthaus, J
    Damen, E
    Belderbos, J
    Lebesque, J
    van Herk, M
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S85 - S85
  • [4] 3-D Synthetic Imaging Using 128-Channel 2-D Sparse CMUT Array
    Choi, Won Young
    Kwak, Yun Sang
    Park, Kwan Kyu
    2017 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2017,
  • [5] Semiautomatic carotid intraplaque hemorrhage volume measurement using 3D carotid MRI
    Liu, Jin
    Sun, Jie
    Balu, Niranjan
    Ferguson, Marina S.
    Wang, Jinnan
    Kerwin, William S.
    Hippe, Daniel S.
    Wang, Amy
    Hatsukami, Thomas S.
    Yuan, Chun
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2019, 50 (04) : 1055 - 1062
  • [6] Sodium 3-D MRI of the human torso using a volume coil
    Steidle, G
    Graf, H
    Schick, F
    MAGNETIC RESONANCE IMAGING, 2004, 22 (02) : 171 - 180
  • [7] Measurement of organ volume using 3D US
    Hughes, SW
    DArcy, TJ
    Ruff, CF
    Maxwell, DJ
    Saunders, JE
    CAR '96: COMPUTER ASSISTED RADIOLOGY, 1996, 1124 : 210 - 215
  • [8] Dynamic MRI of the HCC using 3D FISP
    Shinozaki, K
    Yoshimitsu, K
    Honda, H
    Kuroiwa, T
    Irie, H
    Masuda, K
    RADIOLOGY, 2001, 221 : 126 - 126
  • [9] 3D volume-localized pO2, measurement in the human lung with 3He MRI
    Wild, JM
    Fichele, S
    Woodhouse, N
    Paley, MNJ
    Kasuboski, L
    van Beek, JR
    MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (05) : 1055 - 1064
  • [10] MEASUREMENT OF PLACENTAL VOLUME USING 2D AND 3D ULTRASOUND AS COMPARED TO MRI - A PILOT STUDY
    Sommerfelt, Silje
    Hillestad, Vigdis
    Higgins, Lucy
    Sagberg, Karianne
    Halle, Tuva
    Gjesdal, Kjell-Inge
    Borthne, Arne Sigurd
    Eskild, Anne
    PLACENTA, 2017, 57 : 292 - 292