INTER-SCAN REPRODUCIBILITY OF CAROTID PLAQUE VOLUME MEASUREMENTS BY 3-D ULTRASOUND

被引:15
|
作者
Sandholt, Benjamin V. [1 ]
Collet-Billon, Antoine [2 ]
Entrekin, Robert [2 ]
Sillesen, Henrik H. [1 ]
机构
[1] Univ Copenhagen, Dept Vasc Surg, Rigshosp, Copenhagen, Denmark
[2] Philips Healthcare, Bothell, WA USA
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2018年 / 44卷 / 03期
关键词
Carotid; Plaque; Quantification; Volume; 3-D; Ultrasound; Reproducibility; Maximum plaque thickness; CORONARY-ARTERY-DISEASE; INTIMA-MEDIA THICKNESS; 3-DIMENSIONAL ULTRASOUND; MYOCARDIAL-INFARCTION; RISK-ASSESSMENT; VESSEL WALL; ATHEROSCLEROSIS; QUANTIFICATION; BIOIMAGE; STROKE;
D O I
10.1016/j.ultrasmedbio.2017.10.018
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
We tested a novel 3-D matrix transducer with respect to inter-scan reproducibility of carotid maximum plaque thickness (MPT) and volume measurements. To improve reproducibility while focusing on the largest plaque/most diseased part of the carotid artery, we introduced a new partial plaque volume (PPV) measure centered on MPT. Total plaque volume (TPV), PPV from a 10-mm segment and MPT were measured using dedicated semi-automated software on 38 plaques from 26 patients. Inter-scan reproducibility was assessed using the t-test, Bland-Altman plots and Pearson's correlation coefficient. There was a mean difference of 0.01 mm in MPT (limits of agreement: -0.45 to 0.42 mm, Pearson's correlation coefficient: 0.96). Both volume measurements exhibited high reproducibility, with PPV being superior (limits of agreement: -35.3 mm(3)to 33.5 mm(3), Pearson's correlation coefficient: 0.96) to TPV (limits of agreement: -88.2 to 61.5 mm(3), Pearson's correlation coefficient: 0.91). The good reproducibility revealed by the present results encourages future studies on establishing plaque quantification as part of cardiovascular risk assessment and for follow-up of disease progression over time. (C) 2018 World Federation for Ultrasound in Medicine & Biology. All rights reserved.
引用
收藏
页码:670 / 676
页数:7
相关论文
共 50 条
  • [21] Reliability of tomographic 3D ultrasound in measuring internal carotid artery plaque volume
    Alzahrani, Adel
    Sultan, Salahaden R.
    Aslam, Mohammed
    ACTA RADIOLOGICA, 2023, 64 (11) : 2931 - 2937
  • [22] QUANTIFICATION OF LOCAL VESSEL WALL AND PLAQUE VOLUME CHANGE FOR ASSESSMENT OF EFFECTS OF THERAPIES ON CAROTID ATHEROSCLEROSIS BASED ON 3-D ULTRASOUND IMAGING
    Chen, Xueli
    Zhao, Yuan
    Spence, J. David
    Chiu, Bernard
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2023, 49 (03): : 773 - 786
  • [23] Inter-sonographer reproducibility of carotid ultrasound plaque detection using Mannheim consensus in subclinical atherosclerosis
    Nyman, Emma
    Vanoli, Davide
    Naslund, Ulf
    Gronlund, Christer
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2020, 40 (01) : 46 - 51
  • [24] Reproducibility of carotid ultrasound stenosis and velocity measurements
    Hingorani, A
    Ascher, E
    Markevich, N
    Schutzer, R
    Kallakuri, S
    Hou, A
    Salles-Cunha, S
    CIRCULATION, 2003, 107 (19) : E177 - E177
  • [25] Accelerated Measurement of Carotid Plaque Volume Using Artificial Intelligence Enhanced 3D Ultrasound
    Phair, Alison Shirley
    Carreira, Joao
    Bowling, Frank Lee
    Ghosh, Jonathan
    Smith, Craig
    Rogers, Steven Kristofor
    ANNALS OF VASCULAR SURGERY, 2024, 98 : 317 - 324
  • [26] Inter-scan reproducibility of coronary calcium measurement using multi detector-row computed tomography (MDCT)
    Sabour, Siamak
    Rutten, A.
    van der Schouw, Y. T.
    Atsma, F.
    Grobbee, D. E.
    Mali, W. P.
    Bartelink, M. E. L.
    Bots, M. L.
    Prokop, M.
    EUROPEAN JOURNAL OF EPIDEMIOLOGY, 2007, 22 (04) : 235 - 243
  • [27] Scan-Rescan Reproducibility of Carotid Atherosclerotic Plaque Morphology and Tissue Composition Measurements Using Multicontrast MRI at 3T
    Li, Feiyu
    Yarnykh, Vasily L.
    Hatsukami, Thomas S.
    Chu, Baocheng
    Balu, Niranjan
    Wang, Jinnan
    Underhill, Hunter R.
    Zhao, Xihai
    Smith, Robin
    Yuan, Chun
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (01) : 168 - 176
  • [28] Carotid plaque and its effect on ultrasound carotid distension measurements
    De Schryver, T.
    Kips, J.
    Swillens, A.
    Segers, P.
    4TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, 2009, 22 (1-3): : 1914 - 1917
  • [29] Inter-scan reproducibility of coronary calcium measurement using Multi Detector-Row Computed Tomography (MDCT)
    Siamak Sabour
    A. Rutten
    Y. T. van der Schouw
    F. Atsma
    D. E. Grobbee
    W. P. Mali
    M. E. L. Bartelink
    M. L. Bots
    M. Prokop
    European Journal of Epidemiology, 2007, 22 : 235 - 243
  • [30] Unstable carotid plaque: Identification by transcranial Doppler and 3-D ultrasound and effect of high-dose atorvastatin
    Spence, JD
    Arturo, T
    DiCicco, M
    Fenster, A
    ATHEROSCLEROSIS SUPPLEMENTS, 2003, 4 (02) : 148 - 148