Progress on corrugated waveguide components suitable for ITER ECH&CD transmission lines

被引:0
|
作者
Olstad, R. A. [1 ]
Callis, R. W. [1 ]
Cengher, M. [1 ]
Doane, J. L. [1 ]
Gorelov, Y. A. [1 ]
Grunloh, H. J. [1 ]
Moeller, C. P. [1 ]
Murphy, C. J. [1 ]
机构
[1] Gen Atom Co, San Diego, CA 92186 USA
关键词
D O I
10.1051/epjconf/20123204020
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
The 2 MW cw requirement for ITER EC transmission lines has led GA to design a number of new and modified components, namely power monitors and polarizers to meet this requirement. In addition, the ITER transmission lines may require sliding joints or bellows to accommodate the thermal expansion of the lines and/or vessel motion. The ex-vessel sections of the EC launchers require double seal waveguides, miter bends and possibly double seal sliding joints to assure tritium retention in this region. GA has developed designs for many of these components and some of them have already been tested at high power at the JAEA RF Test Stand. Thermal analyses of the standard GA power monitor miter bend show that our standard design is suitable for 1 MW cw operation when the H-field is in the plane of the miter bend. For 2 MW cw operation a modified design, which also requires H-plane orientation, has been developed and a prototype has been fabricated and is ready for testing. For long pulse/cw operation, a 2 MW calorimetric miter bend with thermally isolated mirror has been designed and a prototype has been fabricated. Since the mirror is thermally isolated, calorimetry on the mirror cooling water can provide a measure of absorbed power. Such a miter bend, when made in a double seal version, could be useful for monitoring total power at the end of an EC transmission line just before the in-vessel section of an EC launcher. A mode analyzer using an all metal water-cooled beam splitter is being developed for use in measuring in real time the HE11 and higher order mode content or total power in EC transmission lines. Such a high power diagnostic can be very useful in optimizing the alignment of the MOU output into a transmission line and in monitoring the HE 11 mode purity at various locations in a transmission line. Prior to making a 63.5 mm 170 GHz version suitable for use on ITER, several prototype 31.75 mm 110 GHz versions have been fabricated and tested at DIII-D. A 170 GHz version is now being fabricated. This paper addresses the performance characteristics, design features and test results for the new and modified components being developed to assure low loss transmission and acceptable component stresses for 2 MW cw operation.
引用
收藏
页数:6
相关论文
共 31 条
  • [21] Mode Conversion Losses in Expansion Units for ITER ECH Transmission Lines
    Schaub, S. C.
    Shapiro, M. A.
    Temkin, R. J.
    Hanson, G. R.
    JOURNAL OF INFRARED MILLIMETER AND TERAHERTZ WAVES, 2016, 37 (01) : 72 - 86
  • [22] Recent advancements in ECH transmission line components for ITER and other devices
    General Atomics, P.O. Box 85608, San Diego, CA 92186-5608
    不详
    University of Karlsruhe, Germany; Forschungszentrum Karlsruhe, Karlsruhe Research Center, FZK; IEEE MTT Society; ITG of Ger. Assoc. for Electr., Electron. and Inf. Technol. VDE, 1600, 715-716 (2004):
  • [23] Recent advancements in ECH transmission line components for ITER and other devices
    Olstad, RA
    Doane, JL
    Moeller, CP
    Takahashi, K
    CONFERENCE DIGEST OF THE 2004 JOINT 29TH INTERNATIONAL CONFERENCE ON INFRARED AND MILLIMETER WAVES AND 12TH INTERNATIONAL CONFERENCE ON TERAHERTZ ELECTRONICS, 2004, : 715 - 716
  • [24] Estimation of RF power absorption and stray distribution at plasma breakdown based on the design of ITER ECH&CD equatorial launcher
    Yajima, S.
    Kajiwara, K.
    Isozaki, M.
    Kobayashi, N.
    Ikeda, R.
    Kobayashi, T.
    Shinya, T.
    Yamazaki, H.
    Takahashi, K.
    FUSION ENGINEERING AND DESIGN, 2021, 170
  • [25] Calculation and Measurement of Higher Order Mode Losses in ITER ECH Transmission Lines
    Kowalski, Elizabeth J.
    Tax, David S.
    Shapiro, Michael A.
    Sirigiri, Jagadishwar R.
    Temkin, Richard J.
    Woskov, Paul P.
    Bigelow, Timothy S.
    Rasmussen, David A.
    2009 34TH INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER, AND TERAHERTZ WAVES, VOLS 1 AND 2, 2009, : 344 - +
  • [26] Investigation of transmission characteristic in corrugated waveguide transmission lines for fusion application
    Takahashi, Koji
    Kajiwara, Ken
    Kasugai, Atsush
    Kobayashi, Noriyuki
    Sakamoto, Keishi
    EIGHTH IEEE INTERNATIONAL VACUUM ELECTRONICS CONFERENCE, 2007, : 275 - +
  • [27] Wideband polarizers, switches and waveguide for overmoded corrugated transmission lines
    Anderson, James Paul
    Doane, John
    Grunloh, Howard
    Brookman, Michael
    Su, David
    FUSION ENGINEERING AND DESIGN, 2019, 146 : 46 - 49
  • [28] The design and performance of waveguide transmission line components for plasma electron cyclotron heating (ECH) systems
    O'Neill, RC
    Doane, JL
    Moeller, CP
    DiMartino, M
    Grunloh, HJ
    Robinson, JI
    17TH IEEE/NPSS SYMPOSIUM ON FUSION ENGINEERING, VOLS 1 AND 2, 1998, : 462 - 464
  • [29] Evaluation of transmission efficiency of the ECH/CD transmission lines in integrated commissioning phase on JT-60SA
    Yamazaki, H.
    Kobayashi, T.
    Takahashi, K.
    Sawahata, M.
    Hiranai, S.
    Toida, N.
    Sato, F.
    Hinata, J.
    Terakado, M.
    Ishita, K.
    Ikeda, R.
    Shinya, T.
    Yajima, S.
    Kajiwara, K.
    FUSION ENGINEERING AND DESIGN, 2023, 196
  • [30] Directional couplers-polarimeters for high-power corrugated waveguide transmission lines
    Simonetto, A
    Solari, G
    Gandini, F
    Granucci, G
    Muzzini, V
    Sozzi, C
    FUSION SCIENCE AND TECHNOLOGY, 2001, 40 (03) : 247 - 252