Correlation between Corneal Endothelial Cell Density and Central Ocular Surface Temperature in Normal and Keratoconus Eyes

被引:3
|
作者
Nemeth, Orsolya [1 ,2 ,3 ]
Langenbucher, Achim [4 ]
Eppig, Timo [4 ]
Lepper, Sabine [5 ]
Milioti, Georgia [5 ]
Abdin, Aladin [5 ]
Nagy, Zoltan Zsolt [3 ]
Seitz, Berthold [5 ]
Szentmary, Nora [1 ,3 ]
机构
[1] Rolf M Schwiete Ctr Limbal Stem Cell & Congenital, D-66424 Homburg, Germany
[2] Markusovszky Univ Teaching Hosp, Dept Ophthalmol, Szombathely, Hungary
[3] Semmelweis Univ, Dept Ophthalmol, Budapest, Hungary
[4] Saarland Univ, Expt Ophthalmol, Homburg, Germany
[5] Saarland Univ, Med Ctr, Dept Ophthalmol, Homburg, Germany
关键词
Endothelial cell density; Ocular termography; Keratoconus;
D O I
10.1080/02713683.2020.1812087
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: In keratoconus (KC), an increase of the corneal back surface area may result in endothelial cell density (ECD) decrease and an increase of the corneal front surface area in ocular surface temperature (OST) decrease due to increased heat dissipation. Along with these hypotheses, we aimed to analyse the correlation between ECD and central corneal OST in patients with KC and healthy controls. Patients and methods: A total of 154 eyes with KC (mean age 36.1 +/- 12.5 years) and 92 healthy eyes (mean age 36.4 +/- 12.8 years) were examined. Corneal front and back surface area at the central 5 mm corneal diameter (FSA and BSA) were calculated based on Pentacam measurement data: FSA or BSA = 2x3.14xR(R-root R-2-D/2)(2), where R referred to corneal front or back surface radius of curvature and D to the corneal front or back surface diameter (5 mm for the present study), respectively. ECD was determined by specular microscopy (EM-3000) and central corneal OST by thermography (TG-1000). Results: ECD was significantly lower in KC (2498 +/- 356/mm(2)) patients than in controls (2638 +/- 294/mm(2); p <.001). FSA (20.35 +/- 0.26 mm(2) vs. 20.17 +/- 0.03 mm(2)) and BSA (20.84 +/- 0.58 mm(2) vs. 20.45 +/- 0.08 mm(2)) were significantly higher in KC patients than in controls (p =.001; p <.001), but the average central corneal OST did not differ significantly between both groups (34.2 +/- 0.6 degrees C vs.34.3 +/- 0.7 degrees C; p =.62). OST at the corneal centre correlated weakly, positively with ECD (r = 0.2; p <.05), but OST did not correlate with FSA (r = 0.045) or BSA (r = 0.064). Conclusions: Endothelial cell density seems to have a mild impact on central ocular surface temperature in keratoconus and normal subjects. This effect is not correlated to the corneal front or back surface area.
引用
收藏
页码:445 / 451
页数:7
相关论文
共 50 条
  • [41] Corneal endothelial cell density in a normal Pakistani population
    Ashraf, KM
    Saeed, MU
    Zia, R
    EYE, 2006, 20 (01) : 116 - 118
  • [42] Corneal endothelial cell density in normal tension glaucoma
    Xu, Jeannie
    Desai, Manishi
    Eliassi-Rad, Babak
    Lee, Hyunjoo Jean
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [43] Corneal endothelial cell density in a normal Pakistani population
    K M Ashraf
    M U Saeed
    R Zia
    Eye, 2006, 20 : 116 - 118
  • [44] Overestimation of corneal endothelial cell density by automated method in glaucomatous eyes with impaired corneal endothelial cells
    Mayumi Minami
    Etsuo Chihara
    International Ophthalmology, 2022, 42 : 133 - 145
  • [45] Overestimation of corneal endothelial cell density by automated method in glaucomatous eyes with impaired corneal endothelial cells
    Minami, Mayumi
    Chihara, Etsuo
    INTERNATIONAL OPHTHALMOLOGY, 2022, 42 (01) : 133 - 145
  • [46] Assessment of corneal endothelial cell density in patients with keratoconus not using contact lenses
    Timucin, Ozgur Bulent
    Karadag, Mehmet Fatih
    Cinal, Adnan
    Asker, Muntecep
    Asker, Selvi
    Timucin, Damla
    CONTACT LENS & ANTERIOR EYE, 2013, 36 (02): : 80 - 85
  • [47] Effect of Metformin on Central Corneal Endothelial Cell Counts in Banked Eyes
    Rai, Dinesh
    Kwon, Ji Won
    Cho, Kyong Jin
    Lee, Jimmy K.
    Gore, Patrick
    McCartney, Mitchell D.
    Chuck, Roy S.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [48] Outcomes of cataract surgery in eyes with a low corneal endothelial cell density
    Yamazoe, Katsuya
    Yamaguchi, Takefumi
    Hotta, Kazuki
    Satake, Yoshiyuki
    Konomi, Kenji
    Den, Seika
    Shimazaki, Jim
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (12): : 2130 - 2136
  • [49] Analysis of Corneal Wavefront Aberrations for Differentiation Between Keratoconus, Pellucid Marginal Degeneration and Normal Eyes
    Ott, D. -L.
    Buehren, J.
    Klaproth, O. K.
    Schwarz, R.
    Kohnen, T.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [50] Central corneal thickness (CCT), corneal curvature (CC), and intraocular pressure (IOP) in hypertensive and normotensive glaucoma eyes, ocular hypertensive eyes, and normal eyes
    Keller, ON
    Bayer, AU
    Erb, C
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S79 - S79