Quantitative characterization of noise in the measurement chain of an optical particle counter

被引:3
|
作者
Borggräfe, P
Trampe, A
Fissan, H
机构
[1] Gerhard Mercator Univ Duisburg, Dept Proc, D-47048 Duisburg, Germany
[2] Gerhard Mercator Univ Duisburg, Aerosol Measurement Technol Div, D-47048 Duisburg, Germany
关键词
optical particle counter; noise; background light; scattering;
D O I
10.1088/0957-0233/13/4/304
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Optical particle counters are deployed for monitoring possible contamination in gases by particles. The counting and sizing of particles are affected by various kinds of interference encountered during measurement. Two sources of interference are background light in the measurement chamber and electrical noise. Such interference causes measurement errors, which stem from the measurement equipment itself and not from the measured object or from the sampling. For the evaluation of measurement error by the particle counter itself, interference for a typical optical particle counter is identified and its effects on the measured results are discussed qualitatively. For the reduction of measurement error, quantitative determination of interference is important. It is only by doing this that we can judge which kind of interference has the more significant influence on measurement error. A method has been developed which makes it possible to determine individual components of interference. This paper presents an experimental method which allows separation of components of background light consisting of light scattering by the molecules and surface. The results of these measurements can be used to optimize existing particle counters as well as new equipment design.
引用
收藏
页码:445 / 450
页数:6
相关论文
共 50 条
  • [31] Development of optical particle counter with double scattering angles
    Li, Xue-Bin
    Gao, Yi-Qiao
    Wei, He-Li
    Ji, Yu-Feng
    Hu, Huan-Ling
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2009, 17 (07): : 1528 - 1534
  • [32] Development of online correlation filter for optical particle counter
    Shaim, Md. Haider Ali
    Chy, Deepak Kumar
    JOURNAL OF OPTICS-INDIA, 2012, 41 (01): : 1 - 15
  • [33] Real time correlation filter for optical particle counter
    Shaim, Md. Haider Ali
    Chy, Deepak Kumar
    OPTICAL AND QUANTUM ELECTRONICS, 2013, 45 (05) : 433 - 448
  • [34] The design of a small flow optical sensor of particle counter
    Zhan, Yongbo
    zhang, Jianwei
    Zeng, Jianxiong
    Li, Bin
    Chen, Lu
    OPTICS COMMUNICATIONS, 2018, 407 : 296 - 300
  • [35] Real time correlation filter for optical particle counter
    Md. Haider Ali Shaim
    Deepak Kumar Chy
    Optical and Quantum Electronics, 2013, 45 : 433 - 448
  • [37] Design of Optical System of Aerosol Microbial Particle Counter
    Zhang Zhiqiang
    Song Fengmin
    Zhang Qin
    Dang Lei
    Xu Yi
    Li Shunbo
    Chen Li
    CHINESE JOURNAL OF LASERS-ZHONGGUO JIGUANG, 2021, 48 (07):
  • [39] Evaluation of a laser-optical resin particle counter
    Yu, LP
    Allen, LH
    Esser, A
    TAPPI JOURNAL, 2003, 2 (03): : 13 - 18
  • [40] RESPONSE OF AN OPTICAL COUNTER AS A FUNCTION OF PARTICLE-SIZE
    POHL, FG
    GOREN, SL
    AEROSOL SCIENCE AND TECHNOLOGY, 1983, 2 (02) : 239 - 239