Agreement of Central Corneal Thickness Measurements between Scheimpflug Photography and Optical Low-Coherence Reflectometry in Children

被引:4
|
作者
Hashemi, Hassan [1 ]
Nabovati, Payam [2 ]
Khabazkhoob, Mehdi [3 ]
Emamian, Mohammad Hassan [4 ]
Yekta, Abbasali [5 ]
Fotouhi, Akbar [6 ]
机构
[1] Noor Eye Hosp, Noor Res Ctr Ophthalm Epidemiol, Tehran, Iran
[2] Iran Univ Med Sci, Rehabil Res Ctr, Sch Rehabil Sci, Dept Optometry, Tehran, Iran
[3] Shahid Beheshti Univ Med Sci, Sch Nursing & Midwifery, Dept Med Surg Nursing, Tehran, Iran
[4] Shahroud Univ Med Sci, Ophthalm Epidemiol Res Ctr, Shahroud, Iran
[5] Mashhad Univ Med Sci, Refract Errors Res Ctr, Sch Paramed Sci, Mashhad, Razavi Khorasan, Iran
[6] Univ Tehran Med Sci, Sch Publ Hlth, Dept Epidemiol & Biostat, Tehran, Iran
关键词
Corneal thickness; corneal imaging; agreement; children; Iran; ULTRASOUND PACHYMETRY; SPECULAR MICROSCOPY; PENTACAM; TOMOGRAPHY; LENSTAR; DEVICES;
D O I
10.1080/08820538.2020.1810288
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose Central corneal thickness (CCT) is a key indicator of the corneal health status and is therefore of clinical importance. The aim of the present study was to determine the agreement between Scheimpflug photography (SP) and optical low-coherence reflectometry (OLCR) systems in measuring the CCT in children. Methods In this cross-sectional study, the samples were selected from Shahroud schoolchildren using cluster sampling. The samples then underwent optometric examinations, including the measurement of visual acuity and refraction. CCT measurements were done by the SP and OLCR systems between 8 am and 4 pm. To evaluate the agreement between these devices, 95% limits of agreement (LoA) and interclass correlation coefficient (ICC) were reported. Results After applying the exclusion criteria, 4890 right eyes (53.2% male) were analyzed. The mean age of the students was 9.22 +/- 1.72 years (range: 6-12 years). The mean CCT by the SP and OLCR systems was 555.30 +/- 34.15 and 550.23 +/- 35.11 mu m, respectively. The 95% LoA between the two devices was -19.81 to 9.66 mu m, and the ICC was 0.983. The CCT difference between the SP and OLCR systems was 5.61 mu m in boys and 3.36 mu m in girls. The CCT difference between the two devices was 6.41 mu m in 6-year-old and 3.54 mu m in 12-year-old children. The 95% LoA was -17.96 to 9.58 mu m and -18.89 to 8.47 mu m and the ICC was 0.987 and 0.984 in myopic and hyperopic subjects, respectively. Conclusion The results of this study showed a high agreement between OLCR and SP measurements of CCT in children.
引用
收藏
页码:252 / 256
页数:5
相关论文
共 50 条
  • [31] Comparison of Anterior Segment Measurements with Optical Low-coherence Reflectometry and Partial-coherence Interferometry Optical Biometers
    Can, Ertugrul
    Duran, Mustafa
    Cetinkaya, Tugba
    Ariturk, Nursen
    MIDDLE EAST AFRICAN JOURNAL OF OPHTHALMOLOGY, 2016, 23 (04) : 288 - 292
  • [32] BRAGG GRATING CHARACTERIZATION BY OPTICAL LOW-COHERENCE REFLECTOMETRY
    LAMBELET, P
    FONJALLAZ, PY
    LIMBERGER, HG
    SALATHE, RP
    ZIMMER, C
    GILGEN, HH
    IEEE PHOTONICS TECHNOLOGY LETTERS, 1993, 5 (05) : 565 - 567
  • [33] MULTIPLEXED SENSING USING OPTICAL LOW-COHERENCE REFLECTOMETRY
    SORIN, WV
    BANEY, DM
    IEEE PHOTONICS TECHNOLOGY LETTERS, 1995, 7 (08) : 917 - 919
  • [34] Multilayer optical storage using low-coherence reflectometry
    Massachusetts Inst of Technology, Lexington, United States
    Conf Proc Laser Electr Optic Soc Annu Meet, (101-102):
  • [35] The Effect of Cycloplegia on the Biometer for Optical Low-coherence Reflectometry
    Yakar, Konuralp
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2024, 241 (12) : 1322 - 1327
  • [36] Spectrum analysis of the optical low-coherence reflectometry system
    Zeng, Shaoqun
    Xu, Haifeng
    Liu, Xiande
    Luo, Qingming
    Li, Zaiguang
    Guangzi Xuebao/Acta Photonica Sinica, 1997, 26 (02): : 136 - 139
  • [37] Spectrum analysis of the optical low-coherence reflectometry system
    Huazhong Univ of Science &, Technology, Hubei, China
    Guangzi Xuebao, 2 (136-139):
  • [38] Comparison between central corneal thickness measurements by ultrasound pachymetry and optical coherence tomography
    Leung, Dexter Y. L.
    Lam, Douglas K. T.
    Yeung, Barry Y. M.
    Lam, Dennis S. C.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2006, 34 (08): : 751 - 754
  • [39] Agreement and clinical comparison between a new swept-source optical coherence tomography-based optical biometer and an optical low-coherence reflectometry biometer
    Arriola-Villalobos, P.
    Almendral-Gomez, J.
    Garzon, N.
    Ruiz-Medrano, J.
    Fernandez-Perez, C.
    Martinez-de-la-Casa, J. M.
    Diaz-Valle, D.
    EYE, 2017, 31 (03) : 437 - 442
  • [40] Comparison of ocular biometry and intraocular lens power using dual Scheimpflug analyzer and optical low-coherence reflectometry
    Han, Kyung Eun
    Lee, Hyo Kyung
    Shin, Minchul
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)