Drift capacity of high-strength concrete columns with mixed-grade longitudinal reinforcements

被引:11
|
作者
Alaee, Pooya [1 ]
Sato, Yoshiharu [2 ]
Li, Bing [1 ]
机构
[1] Nanyang Technol Univ, Sch Civil & Environm Engn, Singapore 639798, Singapore
[2] Taisei Corp, Osaka, Japan
关键词
drift-based design; finite-element analysis; high-strength steel reinforcement; high-strength concrete columns; reinforced concrete; seismic performance; BEHAVIOR;
D O I
10.1177/1369433218794270
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A unique reinforced concrete column design method which aims to improve the ductile behavior of reinforced concrete columns by utilizing various steel grades for longitudinal reinforcements is evaluated in this article. Six large-scale reinforced concrete columns were tested, with the columns subjected to axial load and cyclic forces under reversed bending. The parameters varied in the test program including the axial loading level and the ratio and strength of longitudinal steel reinforcement. It was found from the test results that utilizing longitudinal high-strength steel reinforcement by the ratio of 30%, 50%, and 100% of the total longitudinal reinforcement in a column section will increase the lateral loading drift capacity by 18%, 26%, and 55% on average, respectively. Parametric studies via nonlinear finite-element approach were performed to study the influence of various design parameters on the ultimate drift capacity of reinforced concrete columns. The correlation between the ultimate drift capacity and the confinement level, the axial loading level, and the ratio and grade of longitudinal high-strength reinforcing bars was investigated. Design charts for various ultimate drift levels in terms of other design parameters were developed.
引用
收藏
页码:519 / 534
页数:16
相关论文
共 50 条
  • [21] Behavior of slender high-strength concrete columns
    Mendis, PA
    ACI STRUCTURAL JOURNAL, 2000, 97 (06) : 895 - 901
  • [22] Reliability assessment of high-strength concrete columns
    Diniz, SMC
    Frangopol, DM
    STRUCTURAL SAFETY AND RELIABILITY, VOLS. 1-3, 1998, : 557 - 564
  • [23] Confining reinforcement for high-strength concrete columns
    Li, B
    Park, R
    ACI STRUCTURAL JOURNAL, 2004, 101 (03) : 314 - 324
  • [24] High-strength concrete columns: A design guide
    McFarlane, Angus
    Structural Engineer, 2007, 85 (06): : 31 - 38
  • [25] High-strength concrete columns: State of the art
    Mirza, SA
    Azizinamini, A
    Adebar, PE
    Elwi, AE
    Lee, DD
    Rangan, DV
    Furlong, RW
    MacGregor, JG
    Saadeghvaziri, MA
    Green, R
    Mau, ST
    Saatcioglu, M
    HOrn, HR
    Park, R
    Schultz, AE
    Hsu, CTT
    Paultre, P
    Selna, LG
    Lawrie, RA
    Prishtina, B
    Sheikh, SA
    Rad, RN
    ACI STRUCTURAL JOURNAL, 1997, 94 (03) : 323 - 335
  • [26] Reliability assessment of high-strength concrete columns
    Diniz, SMC
    Frangopol, DM
    JOURNAL OF ENGINEERING MECHANICS-ASCE, 1998, 124 (05): : 529 - 536
  • [27] Seismic performance of high-strength concrete columns
    Xiao, Y
    Martirossyan, A
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1998, 124 (03): : 241 - 251
  • [28] Reliability bases for high-strength concrete columns
    Diniz, SMC
    Frangopol, DM
    JOURNAL OF STRUCTURAL ENGINEERING, 1997, 123 (10) : 1375 - 1381
  • [29] Design of high-strength reinforced concrete columns
    Ou Y.-C.
    Tsai T.-C.
    Ou, Yu-Chen, 2018, Chinese Institute of Civil and Hydraulic Engineering (30): : 223 - 229
  • [30] SPIRALLY REINFORCED HIGH-STRENGTH CONCRETE COLUMNS
    MARTINEZ, S
    NILSON, AH
    SLATE, FO
    JOURNAL OF THE AMERICAN CONCRETE INSTITUTE, 1984, 81 (05): : 431 - 442