Absorbed dose to water distribution measured around an HDR 192Ir brachytherapy source by thermoluminescent dosimeters

被引:5
|
作者
Aviles Lucas, P. [1 ,2 ]
Lourenco, V. [1 ]
Vermesse, D. [1 ]
Cutarella, D. [1 ]
Aubineau-Laniece, I. [1 ]
机构
[1] CEA, LIST, LNHB, F-91191 Gif Sur Yvette, France
[2] CIEMAT, Lab Metrol Radiac Ionizantes, E-28040 Madrid, Spain
关键词
D O I
10.1088/0026-1394/49/5/S228
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The purpose of this work was to develop a procedure to directly estimate the spatial distribution of the absorbed dose rate to water, (D) over dot(w), around an HDR Ir-192 brachytherapy source. The methodology developed was based on Monte Carlo calculations and measurements in air and in water with thermoluminescent detectors. Variations in detector positioning had a significant influence near the brachytherapy source (20% at 1 cm). The method leads to a mean difference of about 7% with the CLRP TG-43 Parameter Database when the absorbed dose to water is characterized along the transverse plane to the source (from 1 cm to about 11 cm). This mean difference, however, is within an uncertainty of 7.7% over all distances. This method therefore can be used to provide direct estimates of the absorbed dose rate to water for HDR brachytherapy source irradiations which are more realistic than those which use other phantom materials. In addition, measurements are indicative of the source geometry and material composition.
引用
收藏
页码:S228 / S230
页数:3
相关论文
共 50 条
  • [41] Enhancement and validation of Geant4 Brachytherapy application on clinical HDR 192Ir source
    Ababneh, Eshraq
    Dababneh, Saed
    Qatarneh, Sharif
    Wadi-Ramahi, Shada
    RADIATION PHYSICS AND CHEMISTRY, 2014, 103 : 57 - 66
  • [42] Dosimetry revisited for the HDR 192Ir brachytherapy source model mHDR-v2
    Granero, Domingo
    Vijande, Javier
    Ballester, Facundo
    Rivard, Mark J.
    MEDICAL PHYSICS, 2011, 38 (01) : 487 - 494
  • [43] TLD DOSIMETRY OF A NEW 192Ir PULSED DOSE RATE BRACHYTHERAPY SOURCE
    Kabiri, F.
    Sheibani, S.
    Ghozzati, B.
    Beigi, H. Pour
    Javanshir, M.
    INTERNAL MEDICINE JOURNAL, 2011, 41 : 45 - 45
  • [44] Measurement of rectum dose by in vivo alanine/ESR dosimetry in gynecological 192Ir HDR brachytherapy
    Bravo-Miranda, Carlos
    Rech, Amanda Burg
    Oliveira, Harley Francisco
    Bertucci, Edenyse
    Cordova-Fraga, Teodoro
    Baffa, Oswaldo
    RADIATION MEASUREMENTS, 2015, 75 : 45 - 52
  • [45] Comparison of 60Co and 192Ir sources in HDR brachytherapy
    Strohmaier, Stefan
    Zwierzchowski, Grzegorz
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2011, 3 (04) : 199 - 208
  • [46] Employing the microDiamond detector for radial dose function measurements with an 192Ir HDR source
    Rossi, G.
    Gainey, M.
    Thomann, B.
    Kollefrath, M.
    Allgaier, B.
    Wuerfel, J.
    Baltas, D.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S1238 - S1239
  • [47] Dose rate measurements of an electronic brachytherapy source using thermoluminescent dosimeters in water
    Pike, T.
    Davis, S.
    Palmer, B.
    DeWerd, L.
    MEDICAL PHYSICS, 2007, 34 (06) : 2609 - 2610
  • [48] Beam quality correction factors for dose measurements around 192Ir brachytherapy sources
    Thrapsanioti, Zoi
    Peppa, Vasiliki
    Hourdakis, Costas J.
    Karaiskos, Pantelis
    Lekatou, Aristea
    Pantelis, Evaggelos
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2025, 26 (01):
  • [49] Development of An Absorbed Dose to Water Primary Standard for HDR Ir-192 Brachytherapy Based On the Fricke Dosimetry System
    El Gamal, I.
    Cojocaru, C.
    Mainegra-Hing, E.
    Ross, C.
    McEwen, M.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [50] A proposal for a novel absorbed dose to water FeSo4-based standard for Ir-192HDR brachytherapy
    deAlmeida, E. C.
    Ochoa, R.
    Coelho, M.
    Austerlitz, C.
    Mota, H. C.
    Sibata, C. H.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S588 - S589