Excessive chest compression rate is associated with insufficient compression depth in prehospital cardiac arrest

被引:75
|
作者
Monsieurs, Koenraad G. [1 ,2 ]
De Regge, Melissa [3 ]
Vansteelandt, Kristof [4 ]
De Smet, Jeroen [5 ]
Annaert, Emmanuel [5 ]
Lemoyne, Sabine [5 ]
Kalmar, Alain F. [6 ]
Calle, Paul A. [2 ]
机构
[1] Univ Antwerp Hosp, Emergency Dept, B-2650 Edegem, Belgium
[2] Univ Ghent, Fac Med & Hlth Sci, B-9000 Ghent, Belgium
[3] Univ Ghent, Dept Management Innovat & Entrepreneurship, B-9000 Ghent, Belgium
[4] Katholieke Univ Leuven, Univ Psychiat Ctr, B-3070 Kortenberg, Belgium
[5] Ghent Univ Hosp, Emergency Dept, B-9000 Ghent, Belgium
[6] Univ Groningen, Univ Med Ctr Groningen, Dept Anaesthesia, NL-9700 RB Groningen, Netherlands
关键词
Cardiac arrest; Cardiopulmonary resuscitation (CPR); Chest compressions; Compression depth; Compression rate; Prehospital; BASIC LIFE-SUPPORT; RESUSCITATION-COUNCIL GUIDELINES; CARDIOPULMONARY-RESUSCITATION; SECTION; QUALITY; FEEDBACK; CPR; PERFORMANCE; GUIDANCE;
D O I
10.1016/j.resuscitation.2012.07.015
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background and goal of study: The relationship between chest compression rate and compression depth is unknown. In order to characterise this relationship, we performed an observational study in prehospital cardiac arrest patients. We hypothesised that faster compressions are associated with decreased depth. Materials and methods: In patients undergoing prehospital cardiopulmonary resuscitation by health care professionals, chest compression rate and depth were recorded using an accelerometer (E-series monitor-defibrillator, Zoll, USA). Compression depth was compared for rates < 80/min, 80-120/min and > 120/min. A difference in compression depth >0.5 cm was considered clinically significant. Mixed models with repeated measurements of chest compression depth and rate (level 1) nested within patients (level 2) were used with compression rate as a continuous and as a categorical predictor of depth. Results are reported as means and standard error (SE). Results and discussion: One hundred and thirty-three consecutive patients were analysed (213,409 compressions). Of all compressions 2% were < 80/min, 62% between 80 and 120/min and 36% > 120/min, 36% were < 4 cm deep, 45% between 4 and 5 cm, 19% > 5 cm. In 77 out of 133 (58%) patients a statistically significant lower depth was observed for rates > 120/min compared to rates 80-120/min, in 40 out of 133 (30%) this difference was also clinically significant. The mixed models predicted that the deepest compression (4.5 cm) occurred at a rate of 86/min, with progressively lower compression depths at higher rates. Rates > 145/min would result in a depth < 4 cm. Predicted compression depth for rates 80-120/min was on average 4.5 cm (SE 0.06) compared to 4.1 cm (SE 0.06) for compressions > 120/min (mean difference 0.4 cm, P < 0.001). Age and sex of the patient had no additional effect on depth. Conclusions: This study showed an association between higher compression rates and lower compression depths. Avoiding excessive compression rates may lead to more compressions of sufficient depth. (C) 2012 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1319 / 1323
页数:5
相关论文
共 50 条
  • [21] Continuous chest compression CPR preferred for primary cardiac arrest
    Ewy, Gordon A.
    Sanders, Arthur B.
    RESUSCITATION, 2010, 81 (06) : 639 - 640
  • [22] Continuous-chest-compression cardiopulmonary resuscitation for cardiac arrest
    Ewy, Gordon A.
    CIRCULATION, 2007, 116 (25) : 2894 - 2896
  • [23] Optimal chest compression technique for paediatric cardiac arrest victims
    Kim, Min Joung
    Lee, Hye Sun
    Kim, Seunghwan
    Park, Yoo Seok
    SCANDINAVIAN JOURNAL OF TRAUMA RESUSCITATION & EMERGENCY MEDICINE, 2015, 23
  • [24] Finger Photoplethysmography to Monitor Chest Compression Rate During Out-of-Hospital Cardiac Arrest
    Elola, Andoni
    Urteaga, Jon
    Aramendi, Elisabete
    Irusta, Unai
    Alonso, Erik
    Daya, Mohamud
    Owens, Pamela
    Idris, Ahamed
    2018 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), 2018, 45
  • [25] Effects of Compliant Chest Compression Rate on Return of Spontaneous Circulation in In-Hospital-Cardiac-Arrest
    Atkins, Janel
    Reynolds, Julia
    Pearson, David
    CIRCULATION, 2024, 150
  • [26] Compression depth in Chest Compressions
    不详
    NOTFALL & RETTUNGSMEDIZIN, 2015, 18 (05): : 344 - 344
  • [27] Poster: Depth and Rate Estimation for Chest Compression CPR with Smartphone
    Amemiya, Tomohiro
    Maeda, Taro
    2013 IEEE SYMPOSIUM ON 3D USER INTERFACES (3DUI), 2013, : 125 - 126
  • [28] Relation between chest compression rate and depth: the ENFONCE Study
    Agostinucci, Jean-Marc
    Weisslinger, Lisa
    Marzouk, Nessrine
    Zouaghi, Haroun
    Ekpe, Kenneth
    Genthillomme, Angelie
    Adnet, Frederic
    Guenin, Aurelien
    Reuter, Paul-Georges
    Lapostolle, Frederic
    EUROPEAN JOURNAL OF EMERGENCY MEDICINE, 2021, 28 (05) : 352 - 354
  • [29] Association of mechanical chest compression and prehospital thrombolysis
    Chenaitia, Hichem
    Fournier, Marc
    Brun, Jean Paul
    Michelet, Pierre
    Auffray, Jean Pierre
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2012, 30 (06): : 1015.e1 - 1015.e2
  • [30] Proportional Versus Fixed Chest Compression Depth for Guideline-Compliant Resuscitation of Infant Asphyxial Cardiac Arrest
    Salcido, David D.
    Koller, Allison C.
    Genbrugge, Cornelia
    Gumucio, Jorge A.
    Menegazzi, James J.
    PREHOSPITAL EMERGENCY CARE, 2024,