Potentiometric determination of dopamine in pharmaceutical preparations by crown ether-PVC membrane sensors

被引:29
|
作者
Othman, AM
Rizka, NMH
El-Shahawi, MS [1 ]
机构
[1] Menoufia Univ, GEBRI, Engn & Biotechnol Res Inst, Sadat City, Egypt
[2] Mansoura Univ, Fac Sci, Dept Chem, Dumyat, Egypt
关键词
D O I
10.2116/analsci.20.651
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two simple, rapid and sensitive sensors for the assay of dopamine hydrochloride have been developed. The methods are based upon the formation of the membrane sensors 12-crown-4-phosphotungestic acid (crown ether-PTA)-dopamine and 12-crown-4-tetraphenylborate (crown ether-TPB)-dopamine as neutral carriers. The sensors were stable and showed fast potential responses of 10 s, and near-Nernstian cationic slopes of 53.3 - 56.2 mV/decade of activity between pH 2.2 - 6 for the monovalent dopamine cation over a wide range concentrations 1 x 10(-5) - 1 x 10(-1) M. The selectivity coefficients of the developed sensors indicated excellent selectivity for dopamine over a large number of organic and inorganic species and pharmaceutical excipients. The mediator o-nitrophenyloctyl ether significantly affected the lifetime of the fabricated sensors of dopamine. Satisfactory results were obtained for the determination of dopamine in dosage form by the proposed sensors with an average recovery of 99.85% for the nominal concentration.
引用
收藏
页码:651 / 655
页数:5
相关论文
共 50 条
  • [31] PVC-Membrane Potentiometric Sensor for the Determination of Tamoxifen in Pharmaceutical Formulations
    Kanberoglu, Gulsah Saydan
    Coldur, Fatih
    Topcu, Cihan
    Cubuk, Osman
    IEEE SENSORS JOURNAL, 2015, 15 (11) : 6199 - 6207
  • [32] Plastic membrane electrode for the potentiometric determination of pethidine hydrochloride in pharmaceutical preparations
    Z.-H. Liu
    M.-L. Wen
    Y. Yao
    J. Xiong
    Fresenius' Journal of Analytical Chemistry, 2000, 368 : 335 - 337
  • [33] Plastic membrane electrode for the potentiometric determination of pethidine hydrochloride in pharmaceutical preparations
    Liu, ZH
    Wen, ML
    Yao, Y
    Xiong, J
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 368 (04): : 335 - 337
  • [34] POTENTIOMETRIC DETERMINATION OF IODINE IN PHARMACEUTICAL PREPARATIONS
    VANDEPUTTE, M
    DRYON, L
    DEHERTOGH, L
    MASSART, DL
    JOURNAL OF PHARMACEUTICAL SCIENCES, 1979, 68 (11) : 1416 - 1418
  • [35] Ionophore-based potentiometric PVC membrane sensors for the determination of moxifloxacin
    Homoda, Atef M. A.
    EGYPTIAN JOURNAL OF CHEMISTRY, 2024, 67 (06): : 387 - 394
  • [36] PVC based monoaza-18-crown-6 membrane potentiometric sensors for cadmium
    Gupta, VK
    Kumar, P
    Mangla, R
    ELECTROANALYSIS, 2000, 12 (10) : 752 - 756
  • [37] PVC membrane electrode for the direct determination of chlorpheniramine maleate in pharmaceutical preparations
    El-Tohamy, Maha
    El-Maamly, Magda
    Shalaby, Abdalla
    ASIAN JOURNAL OF CHEMISTRY, 2007, 19 (04) : 3035 - 3046
  • [38] Determination of diclofenac in pharmaceutical preparations using a novel PVC membrane sensor
    Hassan, SSM
    Mahmoud, WH
    Elmosallamy, MAF
    Almarzooqi, MH
    PHARMAZIE, 2003, 58 (01): : 29 - 31
  • [39] Novel PVC Membrane Selective Electrode for the Determination of Clozapine in Pharmaceutical Preparations
    Al Attas, Amirh S.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2009, 4 (01): : 9 - 19
  • [40] Polymeric Membrane Sensors for the Selective Determination of Dextromethorphan in Pharmaceutical Preparations
    Eman H. El-Naby
    Analytical Sciences, 2008, 24 : 1409 - 1414