Improved microcalcification visualization using dual-energy digital mammography

被引:2
|
作者
Tsai, Chia-Jung [1 ]
Chen, Ran-Chou [2 ,3 ]
Peng, Hui-Ling [4 ]
Hsu, Wen-Lin [5 ,6 ]
Lee, Jason J. S. [2 ]
机构
[1] Chung Shan Med Univ, Dept Med Imaging & Radiol Sci, Taichung, Taiwan
[2] Natl Yang Ming Univ, Dept Biomed Imaging & Radiol Sci, Taipei 112, Taiwan
[3] Taipei City Hosp, Dept Radiol, Taipei, Taiwan
[4] Shin Kong Wu Ho Su Mem Hosp, Dept Diagnost Radiol, Taipei, Taiwan
[5] Tzu Chi Univ, Sch Med, Hualien, Taiwan
[6] Buddhist Tzu Chi Gen Hosp, Dept Radiat Oncol, Hualien, Taiwan
关键词
Dual-energy digital mammography; microcalcification; radiation dose; FILM MAMMOGRAPHY; SUBTRACTION MAMMOGRAPHY; BREAST TOMOSYNTHESIS; OPTIMIZATION; TISSUE; CT;
D O I
10.1177/0284185113481017
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Dual-energy digital mammography (DEDM), involving a combination of high-energy (HE) and low-energy (LE) images, has been investigated as offering a potential improvement in microcalcification detection obscured by overlapping tissue structures. Purpose: To explore the possibility to improve detection of microcalcifications using the DEDM technique. Material and Methods: Three DEDM protocols were performed by adjusting the effective tube current time product (mAs) of LE image at the same (100%), one half (50%), and one-quarter (25%) of that used in HE image acquisition, named DEDM100%, DEDM50%, and DEDM25%, respectively. A single-energy digital mammography (SEDM) method was also used as a control. A total of 525 regions of interest (ROIs) were used to compare the performance of the DEDM to that of SEDM using free-response receiver-operating characteristic (FROC) and areas under the FROC curve (A(z)). Results: All DEDM protocols ranked significantly higher than the SEDM method (P < 0.001). The true-positive fraction was 0.90 for an average of 0.017-0.042 false-positive per image using the DEDM100%, 0.017-0.114 using the DEDM50%, 0.021-0.148 using the DEDM25%, and 0.134-0.422 using the SEDM. The estimated Az values were 0.915-0.940, 0.867-0.935, 0.824-0.930, and 0.567-0.673, respectively. Conclusion: The DEDM50% protocol provided a trade-off benefit between accurate microcalcification detectability and radiation dose for any tissue density. Therefore, the DEDM50% has the potential to minimize excess radiation dose without a negative impact on image quality which could improve earlier diagnosis of breast cancer.
引用
收藏
页码:614 / 621
页数:8
相关论文
共 50 条
  • [31] Dual-energy contrast enhanced digital mammography using a new approach for breast tissue canceling
    Puong, Sylvie
    Bouchevreau, Xavier
    Patoureaux, Fanny
    Iordache, Razvan
    Muller, Serge
    MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
  • [32] AN ENERGY SENSITIVE CASSETTE FOR DUAL-ENERGY MAMMOGRAPHY
    CHAKRABORTY, DP
    BARNES, GT
    MEDICAL PHYSICS, 1986, 13 (04) : 573 - 573
  • [33] AN ENERGY SENSITIVE CASSETTE FOR DUAL-ENERGY MAMMOGRAPHY
    CHAKRABORTY, DP
    BARNES, GT
    MEDICAL PHYSICS, 1989, 16 (01) : 7 - 13
  • [34] A study on dual-energy subtraction mammography
    Ramírez, V
    Brandan, ME
    Ruiz-Trejo, C
    Márquez, JA
    Villaseñor, Y
    MEDICAL PHYSICS, 2004, 724 : 132 - 135
  • [35] Dual-energy mammography: simulation studies
    Bliznakova, K.
    Kolitsi, Z.
    Pallikarakis, N.
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (18): : 4497 - 4515
  • [36] Dual-energy in mammography - Feasibility study
    Jafroudi, H
    Lo, SC
    Li, HA
    Artz, DS
    Freedman, MT
    Mun, SK
    PHYSICS OF MEDICAL IMAGING: MEDICAL IMAGING 1996, 1996, 2708 : 278 - 293
  • [37] DUAL-ENERGY MAMMOGRAPHY - A DETECTOR ANALYSIS
    BOONE, JM
    SHABER, GS
    TECOTZKY, M
    MEDICAL PHYSICS, 1990, 17 (04) : 665 - 675
  • [38] Contrast-enhanced dual-energy digital subtraction mammography: Optimization of the beam energy
    Kwan, ALC
    Boone, JM
    Le-Petross, H
    Lindfors, KK
    Seibert, JA
    Lewin, JM
    Medical Imaging 2005: Physics of Medical Imaging, Pts 1 and 2, 2005, 5745 : 1317 - 1321
  • [39] Compositional breast imaging using a dual-energy mammography protocol
    Laidevant, Aurelie D.
    Malkov, Serghei
    Flowers, Chris I.
    Kerlikowske, Karla
    Shepherd, John A.
    MEDICAL PHYSICS, 2010, 37 (01) : 164 - 174
  • [40] Postmortem validation of breast density using dual-energy mammography
    Molloi, Sabee
    Ducote, Justin L.
    Ding, Huanjun
    Feig, Stephen A.
    MEDICAL PHYSICS, 2014, 41 (08) : 439 - 448