Robotic ultrasound probe handling auxiliary by active compliance control

被引:8
|
作者
Onogi, Shinya [1 ]
Urayama, Yasuhiro [1 ]
Irisawa, Sachie [1 ]
Masuda, Kohji [1 ]
机构
[1] Tokyo Univ Agr & Technol, Grad Sch Bioapplicat & Syst Engn, Koganei, Tokyo 1848588, Japan
基金
日本学术振兴会;
关键词
humanrobot interaction; coordinated motion; ultrasound diagnosis; SYSTEM;
D O I
10.1080/01691864.2013.776941
中图分类号
TP24 [机器人技术];
学科分类号
080202 ; 1405 ;
摘要
This paper describes a support system for ultrasound (US) probe scanning by a robotic probe holding system to support manual handling of an US probe. The system, consisting of an US probe manipulator with parallel link mechanism and a 6-axis force sensor, is able to hold and manipulate an US probe according to force applied to the probe by a technician. To enable the smooth coordinated control, compliance control is used. Moreover, we have proposed velocity-depended viscosity depending on the velocity of the robot. In this study, the appropriate viscosity corresponding to operational velocity was measured experimentally and the feasibility of the coordinated motion control was validated. The results of the viscosity measurement showed a clear inverse correlation between the viscosity and the operational velocity. In the coordinated motion control evaluation, the relation between the applied force and the robot velocity in the viscosity of high, low, and dynamic velocity-depended coefficient was measured. The result showed the dynamic velocity-depended viscosity provides well-coordinated motion in any operational velocities. The results demonstrated the system has a great potential for support of US diagnosis as an auxiliary medical robot.
引用
收藏
页码:503 / 512
页数:10
相关论文
共 50 条
  • [31] Ultrasound Probe and Needle-Guide Calibration for Robotic Ultrasound Scanning and Needle Targeting
    Kim, Chunwoo
    Chang, Doyoung
    Petrisor, Doru
    Chirikjian, Gregory
    Han, Misop
    Stoianovici, Dan
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (06) : 1728 - 1734
  • [32] AUTOMATED ROBOTIC DEBURRING OF PARTS USING COMPLIANCE CONTROL
    HER, MG
    KAZEROONI, H
    JOURNAL OF DYNAMIC SYSTEMS MEASUREMENT AND CONTROL-TRANSACTIONS OF THE ASME, 1991, 113 (01): : 60 - 66
  • [33] A Compliance Control Design for Safe Motion of a Robotic Manipulator
    Song, Kai-Tai
    Hsu, Chieh-Hsun
    2011 9TH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION (WCICA 2011), 2011, : 920 - 925
  • [34] Compliance Control of Wearable Robotic Fingers for Rehabilitation Applications
    Song, Kai-Tai
    Chai, Yea-Yen
    2013 CACS INTERNATIONAL AUTOMATIC CONTROL CONFERENCE (CACS), 2013, : 306 - 311
  • [35] Design and Compliance Control of a Robotic Gripper for Orange Harvesting
    Shah, Syed Humayoon
    Arsalan, Muhammad
    Khan, S. G.
    Khan, Muhammad Tufail
    Alam, Muhammad Shahab
    2019 22ND IEEE INTERNATIONAL MULTI TOPIC CONFERENCE (INMIC), 2019, : 78 - 82
  • [36] Modeling and control of fluidic robotic joints with natural compliance
    Mihajlov, Miroslav
    Huebner, Matthias
    Ivlev, Oleg
    Graeser, Axel
    PROCEEDINGS OF THE 2006 IEEE INTERNATIONAL CONFERENCE ON CONTROL APPLICATIONS, VOLS 1-4, 2006, : 1553 - 1558
  • [37] CARTESIAN CONTROL OF ROBOTIC MANIPULATORS WITH JOINT COMPLIANCE.
    Hill, S.D.
    Vaccaro, R.J.
    Robotica, 1987, 5 (pt 3) : 207 - 215
  • [38] Robotic Comanipulation with Active Impedance Control
    Cortesao, Rui
    Zenowich, Brian
    Araujo, Rui
    Townsend, William
    WINVR2009: PROCEEDINGS OF THE ASME/AFM WORLD CONFERENCE ON INNOVATIVE VIRTUAL REALITY - 2009, 2009, : 129 - 135
  • [39] ACTIVE VIBRATION CONTROL FOR ROBOTIC MACHINING
    Wang, Zheng
    Keogh, Patrick
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2017, VOL 2, 2018,
  • [40] ROBOTIC PARTIAL NEPHRECTOMY USING A ROBOTIC ULTRASOUND PROBE FOR TUMOR IDENTIFICATION: INITIAL SERIES AND OUTCOMES
    Rogers, Craig
    Sukumar, Shyam
    Petros, Firas
    Trinh, Quoc-Dien
    Sammon, Jesse D.
    Menon, Mani
    JOURNAL OF ENDOUROLOGY, 2011, 25 : A304 - A304