Prediction of DC flashover voltage of cap-and-pin polluted insulator

被引:4
|
作者
Abimouloud, Adel [1 ]
Arif, Salem [2 ]
Korichi, Dris [1 ]
Ale-Emran, Sayyed Mahdi [3 ]
机构
[1] Univ Kasdi Merbah Ouargla, Lab Genie Elect LAGE, Ouargla 30000, Algeria
[2] Univ Amar Telidji Laghouat, Lab Anal & Commande Syst Energie & Reseaux Elect, BP 37G Laghouat, Laghouat 03000, Algeria
[3] Univ Quebec Chicoutimi, 555 Blvd Univ, Chicoutimi, PQ G7H 2B1, Canada
关键词
ARC; MODEL; PERFORMANCE; RESISTANCE; BEHAVIOR;
D O I
10.1049/iet-smt.2018.5105
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The aim of this work is to estimate the flashover voltage of cap-and-pin insulator using a novel improvement of the pollution resistance evaluation. In cap-and-pin suspension insulators, local arcing starts around the pin where the dry bands first appear due to the evaporation of the conductive layer. In appropriate conditions, a unique dominant arc starting from the pin propagates toward the cap resulting in a complete flashover. Since the highest current density is concentrated around the arc root during propagation, the pollution layer residual resistance variation, with respect to the arc position, is non-linear. Thus an original three-dimensional model, which depicts a real insulator using COMSOL Multiphysics (TM) to evaluate the residual resistance, is developed. This model takes into consideration the actual geometry of the insulator and the current restriction at the arc root for a specific arc radius. A novel mathematical model for calculating the residual resistance of this polluted insulator was elaborated for all possible arc radii. The mathematical model and the 3D simulation results are in satisfactory agreement. To evaluate the flashover voltage, a new approach based on Saddle Point Finding Method is proposed. The new approach and model have been validated using experimental results of previous studies.
引用
收藏
页码:279 / 286
页数:8
相关论文
共 50 条
  • [41] Critical flashover voltage mechanism and prediction of resin epoxy insulator on temperature changes
    Garniwa, I
    PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2003, : 397 - 400
  • [42] Flashover Characteristics along the Insulator in SF6 Gas under DC Voltage
    Jia, Zhijie
    Zhang, Bin
    Tan, Xiaoya
    Zhang, Qiaogen
    2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 3409 - 3412
  • [43] AC flashover performance and voltage of long polluted and iced XP-70 suspension insulator string
    Jiang, XL
    Sun, CX
    Shu, LC
    Sima, WX
    PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2003, : 158 - 161
  • [44] Broadening the Application of the Quick Flashover Test for RTV Pre-coated Glass Cap-and-pin Insulators Sampled from Service in the Italian Transmission Grid
    Marzinotto, Massimo
    Mazzanti, Giovanni
    Panara, Alessandro
    2019 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2019, : 255 - 258
  • [45] Influence of Surface Charge on Flashover Voltage of Gas Insulated Substation Basin Insulator under AC and DC Voltage
    Qi B.
    Gao C.
    Zhao L.
    Li C.
    Tu Y.
    Gaodianya Jishu/High Voltage Engineering, 2017, 43 (03): : 915 - 922
  • [46] A new approach for the flashover voltage prediction using an arc propagation reproduction on a high-voltage insulator
    Doufene, Dyhia
    Benharat, Samira
    Essmine, Abdelmoumen
    Bouzegaou, Oussama
    Bouazabia, Slimane
    COMPEL-THE INTERNATIONAL JOURNAL FOR COMPUTATION AND MATHEMATICS IN ELECTRICAL AND ELECTRONIC ENGINEERING, 2024, 43 (03) : 519 - 534
  • [47] Influence of length and arrangement of iced insulator strings on DC flashover voltage at high altitude districts
    State Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University, Chongqing 400030, China
    Zhongguo Dianji Gongcheng Xuebao, 2008, 3 (1-5):
  • [48] Investigation on Flashover Voltage and Non-uniform Pollution Correction Coefficient of DC Composite Insulator
    Jiang, Xingliang
    Zhang, Zhijin
    Hu, Jianlin
    ICHVE 2008: 2008 INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION, 2008, : 104 - 108
  • [49] Flashover voltage of insulator under artificial rain
    Chrzan, Krystian Leonard
    Streubel, Harri
    PRZEGLAD ELEKTROTECHNICZNY, 2009, 85 (04): : 165 - 168
  • [50] Modified Peek formula for calculating positive DC corona inception voltage on polluted insulator
    M. L. Amrani
    S. Bouazabia
    I. Fofana
    F. Meghnefi
    M. Jabbari
    Electrical Engineering, 2019, 101 : 489 - 498