Calibration of the multichannel sensor of a plane angle in dynamic and static modes

被引:0
|
作者
Agapov, MY [1 ]
Bournashev, MN [1 ]
Loukianov, DP [1 ]
Mironov, AV [1 ]
Filatov, YV [1 ]
机构
[1] St Petersburg State Electrotech Univ, Dept Autonomous Navigat Control & Mech, St Petersburg 197376, Russia
关键词
a dynamic goniometric bench; photoelectric angle encoder; interference zero-point unit; dynamical inaccuracy;
D O I
10.1117/12.454657
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The work concerns to the computerized techniques of quality estimation of automated top precision an-le-code converters. Study of instrumental errors of a rotor position sensor (RPS) with use of goniometric rotary bench (GRB) was made, the plane angle accuracy being got from an optical interferential flat-mirror-zero-point module of original design and a photoelectric angle encoder of RON-905 type manufactured by the "Heidenhein" Corporation (Germany) Also a research was made of inaccuracies of the goniometric rotary bench itself, and also the methods have been developed for definition of inaccuracies due to dynamical behavior of measurement of an angle, and both for their algorithmic elimination Study of systematic, random, and dynamical inaccuracies of both the standard sensor RON-905, and the tested uric, RPS, was carried out. Research of dynamic inaccuracy of said angle measurements was made by means of interrelation between angular rate of rotation and changing of the measured angle interval from the interferential zero-label to the certain selected RON label. The latter data gave rise to close algorithmic elimination of a dynamical error arisen from RON own delay time, In this way, it became possible to calibrate the tested sensor in a very broad range of rotation rate and in several modes of rotation with a steady accuracy. The developed techniques provide calibration of sensors in a case of a rotary bench movement with the composite postulated law of a turn angle against time.
引用
收藏
页码:66 / 71
页数:6
相关论文
共 50 条
  • [21] Sensor node calibration in presence of a dominant reflective plane
    Tegler, Erik
    Larsson, Martin
    Oskarsson, Magnus
    Astrom, Kalle
    2022 30TH EUROPEAN SIGNAL PROCESSING CONFERENCE (EUSIPCO 2022), 2022, : 1941 - 1945
  • [23] Nanoradian angle sensor and in situ self-calibration
    Zhang, Shizhou
    Kiyono, Satoshi
    Uda, Yutaka
    Applied Optics, 1998, 37 (19): : 4154 - 4159
  • [24] Nanoradian angle sensor and in situ self-calibration
    Zhang, SZ
    Kiyono, S
    Uda, Y
    APPLIED OPTICS, 1998, 37 (19): : 4154 - 4159
  • [25] AE sensor calibration for out-of-plane and in-plane displacement sensitivity
    Theobald, P.
    Dar, F.
    ACOUSTIC EMISSION TESTING, 2006, 13-14 : 91 - +
  • [26] Pressure Sensors: Working Principles of Static and Dynamic Calibration
    Pereira, Jose Dias
    SENSORS, 2024, 24 (02)
  • [27] COMPARISON OF STATIC AND DYNAMIC CALIBRATION METHODS FOR IONIZATION GAUGES
    MEINKE, C
    REICH, G
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY, 1967, 4 (06): : 356 - &
  • [28] Static and dynamic calibration of radar data for hydrological use
    Wood, SJ
    Jones, DA
    Moore, RJ
    HYDROLOGY AND EARTH SYSTEM SCIENCES, 2000, 4 (04) : 545 - 554
  • [29] Static and dynamic calibration of torsional spring constants of cantilevers
    Labuda, Aleksander
    Cao, Changhong
    Walsh, Tim
    Meinhold, Jieh
    Proksch, Roger
    Sun, Yu
    Filleter, Tobin
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2018, 89 (09):
  • [30] Static and Dynamic Model Calibration for Upper Thermosphere Determination
    Ruan, Haibing
    Lei, Jiuhou
    Lu, Jianyong
    SPACE WEATHER-THE INTERNATIONAL JOURNAL OF RESEARCH AND APPLICATIONS, 2024, 22 (12):