Assessment of the mitral valve coaptation zone with 2D and 3D transesophageal echocardiography before and after mitral valve repair

被引:12
|
作者
Guo, Yong [1 ]
He, Yihua [1 ]
Zhang, Ye [1 ]
Ge, Shuping [2 ]
Sun, Lin [1 ]
Liu, Wenxu [1 ]
Han, Jiancheng [1 ]
Gu, Xiaoyan [1 ]
机构
[1] Capital Med Univ, Beijing An Zhen Hosp, Dept Ultrasound, Beijing 100029, Peoples R China
[2] Drexel Univ, St Christophers Hosp Children, Coll Med, Philadelphia, PA 19104 USA
关键词
Mitral valve repair; echocardiography; mitral valve coaptation; RESTRICTIVE ANNULOPLASTY; REGURGITATION; PROLAPSE; GEOMETRY;
D O I
10.21037/jtd.2017.12.62
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background: Mitral valve (MV) coaptation is very important in MV repair patients. But accurate quantitation of the degree of MV coaptation remains challenging. This study aimed to evaluate the utility of two-dimensional (2D) and three-dimensional (3D) transesophageal echocardiography (TEE) to assess MV coaptation before and after MV repair. Methods: Forty-eight patients [(age: 52.23 +/- 13.31 years; 26 men (54.17%)] undergoing MV repair for mitral regurgitation (MR) were studied. We assessed the utility of 2D and 3D TEE to assess MV coaptation before and after MV repair. Complete conventional 2D and 3D TEE studies were performed, and the degree of the MV coaptation defect before and after surgery was assessed by measuring the MV coaptation length (CL) and length index (CLI) with 2D TEE, and the coaptation area (CA) and coaptation area index (CAI) with 3D TEE. Results: CL and CLI were measured successfully in 46 (95.83%) patients and CA and CAI in 39 (81.25%). Compared with preoperatively, postoperative CL, CLI, CA, and CAI were significantly increased (CL: 4.99 +/- 0.79 to 9.66 +/- 1.09 mm, P<0.05; CLI: 9.30%+/- 2.66% to 38.24%+/- 3.82%, P<0.05; CA: 158.49 +/- 64.17 to 371.33 +/- 143.57 mm(2), P<0.05; CAI: 9.71%+/- 2.76% to 36.24%+/- 7.26%, P<0.05). Spearman's rank correlation analysis revealed that the CLI and CAI had a significant negative correlation with the degree of MR (r=-0.97, P<0.01; r=-0.92, P<0.01, respectively). Furthermore, Pearson's correlation analysis revealed that the CLI was significantly correlated with the CAI both preoperatively (r=-0.66, P<0.01) and postoperatively (r=-0.67, P<0.01). Conclusions: The coaptation variables increased significantly in patients undergoing MV repair. The CLI and CAI significantly correlated with MR severity. The CL and CLI determined with 2D TEE are more feasible than the CA and CAI determined with 3D TEE. Both 2D and 3D variables may complement each other for aiding MV repair. 2D CLI is an alternative to 3D CAI due to its simplicity.
引用
收藏
页码:283 / 290
页数:8
相关论文
共 50 条
  • [21] Stuck Prosthetic Mitral Valve After AV Canal Defect Repair: Intraoperative 3D Transesophageal Echocardiography Diagnosis
    Singh, Avneet
    Negi, Sunder
    Mahajan, Sachin
    ANNALS OF CARDIAC ANAESTHESIA, 2023, 26 (02) : 239 - +
  • [22] Quantitative Assessment of Mitral Valve Coaptation Using Three-Dimensional Transesophageal Echocardiography
    Cobey, Frederick C.
    Swaminathan, Madhav
    Phillips-Bute, Barbara
    Hyca, Martin
    Glower, Donald D.
    Douglas, Pamela S.
    Shaw, Andrew D.
    Mathew, Joseph P.
    Mackensen, G. Burkhard
    ANNALS OF THORACIC SURGERY, 2014, 97 (06): : 1998 - 2004
  • [23] Understanding the anatomy of a perforated mitral valve: From 2D echocardiography to 3D printing
    Theodoropoulos, Konstantinos C.
    Papachristidis, Alexandros
    Fonseca, Tiago
    Reiken, Joseph
    Monaghan, Mark J.
    HELLENIC JOURNAL OF CARDIOLOGY, 2019, 60 (04) : 264 - 265
  • [24] 3D ECHOCARDIOGRAPHIC ASSESSMENT OF MITRAL ANNULAR DIMENSIONS AND RISK OF MITRAL STENOSIS AFTER TRANSCATHETER MITRAL VALVE REPAIR
    Khan, Mohammed Hasan
    Zaid, Syed
    Goldberg, Joshua
    Dutta, Tanya
    Undemir, Cenap
    Bennett, Joanne
    Cohen, Martin
    Lansman, Steven
    Tang, Gilbert
    Ahmad, Hasan
    Spevack, Daniel
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 75 (11) : 1311 - 1311
  • [25] A Unique Case of Mitral Valve Dehiscence Post-mitral Valve Repair Diagnosed Using 3D Transesophageal Imaging
    Patel, Raj D.
    Ahmad, Mansoor
    Ghadiam, Harshavardhan
    Kizhakekuttu, Tinoy
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2020, 12 (01)
  • [26] PERCUTANEOUS EDGE-TO-EDGE MITRAL VALVE REPAIR - ANALYSIS OF PROCEDURAL EFFECTS BY 2D AND 3D TRANSESOPHAGEAL ECHOCARDIOGRAPHY WITH AND WITHOUT COLOR DOPPLER
    Altiok, Ertunc
    Brehmer, Kathrin
    Reith, Sebastian
    Becker, Michael
    Marx, Nikolaus
    Hoffmann, Rainer
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (14) : E1346 - E1346
  • [27] 3D Echocardiographic Assessment of Mitral Annular Dimensions and Risk of Mitral Stenosis After Transcatheter Mitral Valve Repair
    Khan, Mohammed Hasan
    Zaid, Syed
    Biswas, Medha
    Goldberg, Joshua
    Dutta, Tanya
    Undemir, Cenap
    Bennett, Joanne
    Cohen, Martin
    Lansman, Steven
    Ahmad, Hasan
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 76 (17) : B149 - B149
  • [28] Mitral Valve Annulus Localization in 3D Echocardiography
    Tiwari, Abhishek
    Patwardhan, Kedar A.
    2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 1087 - 1090
  • [29] Mitral valve extraction for real 3D echocardiography
    Gao, Yan
    Yang, Xin
    Shang, Yanfeng
    Wu, Lanping
    Sun, Kun
    Shuju Caiji Yu Chuli/Journal of Data Acquisition and Processing, 2007, 22 (03): : 304 - 308
  • [30] Dynamic quantitative evaluation of Cosgrove mitral valve rings by transesophageal 3D echocardiography
    DallAgata, A
    Taams, MA
    TenCate, FJ
    vanHerwerden, LA
    CIRCULATION, 1996, 94 (08) : 1955 - 1955