Fast Dynamic Reconstruction Algorithm with Joint Bilateral Filtering for Perfusion C-arm CT

被引:0
|
作者
Manhart, Michael [1 ]
Kowarschik, Markus [2 ]
Fieselmann, Andreas [1 ,3 ]
Yu Deuerling-Zheng [2 ]
Hornegger, Joachim [1 ,3 ]
机构
[1] Univ Erlangen Nurnberg, Pattern Recognit Lab, Dept Comp Sci, Martensstr 3, D-91058 Erlangen, Germany
[2] Siemens AG, Angiog & Intervent X Ray Syst, Forchheim, Germany
[3] Erlangen Grad Sch Adv Opt Technol SAOT, Erlangen, Germany
关键词
Perfusion imaging; dynamic reconstruction; C-arm CT; stroke treatment; MODEL;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Tissue perfusion measurement using C-arm angiography systems is a novel technique with potential high benefit for catheter-guided treatment of stroke in the interventional suite. However, perfusion C-arm CT (PCCT) is challenging: the slow C-arm rotation speed only allows measuring samples of contrast time attenuation curves (TACs) every 5 - 6 s if reconstruction algorithms for static data are used. Furthermore, the peaks of the tissue TACs typically lie in a range of 5 - 30 HU, thus perfusion imaging is very sensitive to noise. We present a dynamic, iterative reconstruction (DIR) approach to reconstruct TACs described by a weighted sum of linear spline functions. The optimization problem is solved using an appropriate initialization and a Landweber-based optimization strategy with a modified backprojection step. To reduce noise a novel regularization technique based on joint bilateral filtering (JBF) is introduced. The algorithm is evaluated using simulation data created with a dynamic cylindrical phantom, a realistic digital brain phantom and real measured data from an animal study with a canine stroke model. Results indicate that the DIR algorithm qualitatively and quantitatively improves reconstructed TACs and perfusion maps compared to classical Feldkamp (FDK) reconstruction. For the brain phantom study the Pearson correlation (PC) of the reconstructed cerebral blood flow (CBF) maps to the ground truth increased from 0.82 (FDK) to 0.87 (DIR). For the canine study the PC of the CBF maps to co-registered perfusion CT maps increased from 0.61 (FDK) to 0.73 (DIR).
引用
收藏
页码:2304 / 2311
页数:8
相关论文
共 50 条
  • [41] Image artefact propagation in motion estimation and reconstruction in interventional cardiac C-arm CT
    Mueller, K.
    Maier, A. K.
    Schwemmer, C.
    Lauritsch, G.
    De Buck, S.
    Wielandts, J-Y
    Hornegger, J.
    Fahrig, R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (12): : 3121 - 3138
  • [42] Image reconstruction method based on backprojection filtration algorithm in C-arm computed tomography
    Wang, Xianchao
    Wu, Qilin
    Xu, Pan
    Lu, Zheng
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [43] C-arm tracking and reconstruction without an external tracker
    Jain, Ameet
    Fichtinger, Gabor
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2006, PT 1, 2006, 4190 : 494 - 502
  • [44] A comparison of reconstruction algorithms for C-arm mammography tomosynthesis
    Rakowski, Joseph T.
    Dennis, Michael J.
    MEDICAL PHYSICS, 2006, 33 (08) : 3018 - 3032
  • [45] Fast CBCT Reconstruction using Convolutional Neural Networks for Arbitrary Robotic C-arm Orbits
    Russ, Tom
    Ma, Yiqun Q.
    Golla, Alena-Kathrin
    Bauer, Dominik F.
    Reynolds, Tess
    Toennes, Christian
    Hatamikia, Sepideh
    Schad, Lothar R.
    Zoellner, Frank G.
    Gang, Grace J.
    Wang, Wenying
    Stayman, J. Webster
    MEDICAL IMAGING 2022: PHYSICS OF MEDICAL IMAGING, 2022, 12031
  • [46] Limited angle C-arm tomosynthesis reconstruction algorithms
    Malalla, Nuhad A. Y.
    Xu, Shiyu
    Chen, Ying
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [47] Ray tracing reconstruction investigation for C-arm tomosynthesis
    Malalla, Nuhad A. Y.
    Chen, Ying
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [48] Fast Marker Based C-Arm Pose Estimation
    Kainz, Bernhard
    Grabner, Markus
    Ruether, Matthias
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2008, PT II, PROCEEDINGS, 2008, 5242 : 652 - 659
  • [49] Circular tomosynthesis for neuro perfusion imaging on an interventional C-arm
    Claus, Bernhard E.
    Langan, David A.
    Al Assad, Omar
    Wang, Xin
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [50] Statistical model registration for a C-arm CT system
    Fleute, M
    Desbat, L
    Martin, R
    Lavallée, S
    Defrise, M
    Liu, X
    Taylor, R
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1667 - 1670