A comparison of fast spin-echo, fluid-attenuated inversion-recovery, and diffusion-weighted MR imaging in the first 10 days after cerebral infarction

被引:0
|
作者
Ricci, PE [1 ]
Burdette, JH
Elster, AD
Reboussin, DM
机构
[1] Wake Forest Univ, Bowman Gray Sch Med, Dept Radiol, Winston Salem, NC 27157 USA
[2] Wake Forest Univ, Bowman Gray Sch Med, Dept Publ Hlth Sci, Winston Salem, NC 27157 USA
关键词
D O I
暂无
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Echo-planar diffusion-weighted and fluid-attenuated inversion-recovery (FLAIR) imaging have both proved valuable for detecting acute ischemic infarcts, but little is known about the value of diffusion-weighted imaging beyond the acute infarct period. Furthermore, no direct comparison of the techniques has been published. We compared the diagnostic utility of diffusion-weighted, FLAIR, and T2-weighted fast spin-echo (FSE) imaging for detecting cerebral infarctions up to 10 days old. METHODS: FSE, FLAIR, and diffusion-weighted MR sequences were obtained prospectively over a 6-month period in 212 patients with suspected cerebral infarctions, Seventy patients with nonhemorrhagic ischemic infarcts less than 10 days old whose symptoms lasted longer than 48 hours were identified. The three sequences were compared for detectability and conspicuity of abnormalities that correlated with the neurologic deficit. RESULTS: Seventy-two symptomatic infarcts were found in the 70 patients, Diffusion-weighted imaging detected 70 (97%), FLAIR, 69 (96%), and FSE, 64 (89%) of the 72 lesions. Only the difference between diffusion-weighted and FSE imaging approached statistical significance. There was no difference in the number of lesions detected in the patients imaged 48 hours or more after infarction, Lesion conspicuity on diffusion-weighted images was judged superior to that on FSE and FLAIR images in 55 (77%) and 47 (67%) of the cases, respectively. FLAIR images were judged superior to FSE in 34 (48%) of the cases, CONCLUSION: Diffusion-weighted images showed more infarcts than FLAIR and FSE images, and FLAIR images showed more than FSE images, but the differences were not statistically significant. Lesion conspicuity, however, was consistently better on diffusion-weighted images than on either FLAIR or FSE images throughout the Ill-day period, Acquisition of diffusion-weighted images in the late acute and subacute periods after ischemic cerebral infarction appears to be beneficial.
引用
收藏
页码:1535 / 1542
页数:8
相关论文
共 50 条
  • [41] Comparison of T1-weighted fast spin-echo and T1-weighted fluid-attenuated inversion recovery images of the lumbar spine at 3.0 Tesla
    Lavdas, Eleftherios
    Vlychou, Marianna
    Arikidis, Nikos
    Kapsalaki, Eftychia
    Roka, Violetta
    Fezoulidis, Ioannis V.
    ACTA RADIOLOGICA, 2010, 51 (03) : 290 - 295
  • [42] Radiological diagnosis of acute stroke -: Comparison of conventional MR imaging, echo-planar diffusion-weighted imaging, and spin-echo diffusion-weighted imaging
    Geijer, B
    Brockstedt, S
    Lindgren, A
    Ståhlberg, F
    Norrving, B
    Holtås, S
    ACTA RADIOLOGICA, 1999, 40 (03) : 255 - 262
  • [43] T1-weighted fluid-attenuated inversion recovery and T1-weighted fast spin-echo contrast-enhanced imaging: A comparison in 20 patients with brain lesions
    Al-Saeed, O.
    Ismail, M.
    Athyal, R. P.
    Rudwan, M.
    Khafajee, S.
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2009, 53 (04) : 366 - 372
  • [44] The usefulness of diffusion-weighted/fluid-attenuated inversion recovery imaging in the diagnostics and timing of lacunar and nonlacunar stroke
    Witkowski, Grzegorz
    Piliszek, Agnieszka
    Sienkiewicz-Jarosz, Halina
    Skierczynska, Agnieszka
    Poniatowska, Renata
    Dorobek, Malgorzata
    Filipek-Gliszczynska, Anna
    Ryglewicz, Danuta
    Walecki, Jerzy
    NEURORADIOLOGY, 2014, 56 (10) : 825 - 831
  • [45] Spinal cord infarction demonstrated on diffusion-weighted MR imaging with a single-shot fast spin-echo sequence
    Fujikawa, A
    Tsuchiya, K
    Koppera, P
    Aoki, C
    Hachiya, J
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2003, 27 (03) : 415 - 419
  • [46] The usefulness of diffusion-weighted/fluid-attenuated inversion recovery imaging in the diagnostics and timing of lacunar and nonlacunar stroke
    Grzegorz Witkowski
    Agnieszka Piliszek
    Halina Sienkiewicz-Jarosz
    Agnieszka Skierczyńska
    Renata Poniatowska
    Małgorzata Dorobek
    Anna Filipek-Gliszczynska
    Danuta Ryglewicz
    Jerzy Walecki
    Neuroradiology, 2014, 56 : 825 - 831
  • [48] White matter lesion contrast in fast spin-echo fluid-attenuated inversion recovery imaging: Effect of varying effective echo time and echo train length
    Barboriak, DP
    Provenzale, JM
    MacFall, JR
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 173 (04) : 1091 - 1096
  • [49] Can Diffusion-Weighted Imaging-Fluid-Attenuated Inversion Recovery Mismatch (Positive Diffusion-Weighted Imaging/Negative Fluid-Attenuated Inversion Recovery) at 3 Tesla Identify Patients With Stroke at <4.5 Hours?
    Emeriau, Samuel
    Serre, Isabelle
    Toubas, Olivier
    Pombourcq, Francis
    Oppenheim, Catherine
    Pierot, Laurent
    STROKE, 2013, 44 (06) : 1647 - 1651
  • [50] ACUTE SUBARACHNOID HEMORRHAGE - MR-IMAGING WITH FLUID-ATTENUATED INVERSION-RECOVERY PULSE SEQUENCES
    NOGUCHI, K
    OGAWA, T
    INUGAMI, A
    TOYOSHIMA, H
    SUGAWARA, S
    HATAZAWA, J
    FUJITA, H
    SHIMOSEGAWA, E
    KANNO, I
    OKUDERA, T
    UEMURA, K
    YASUI, N
    RADIOLOGY, 1995, 196 (03) : 773 - 777