Carotid atherosclerosis is a major cause of stroke. Imaging and monitoring plaque progression in 3D can better classify disease severity and potentially identify plaque vulnerability to rupture. In this study we propose to validate a new semiautomatic carotid lumen segmentation algorithm based on 3D ultrasound imaging that is designed to work in the presence of poor boundary contrast and complex 3D lumen geometries. Our algorithm uses a distance regularized level set evolution with a novel initialization and stopping criteria to localize the lumen-intima boundary (LIB). The external energy used in the level set method is a combination of region-based and edge-based energy. Initialization of LIB segmentation is first done in the longitudinal slice where the geometry of the carotid bifurcation is best visualized and then reconstructed in the cross sectional slice to guide the 3D initialization. Manual initialization of the contour is done only on the starting slice of the common carotid, bifurcation, and internal & external carotid arteries. Initialization of the other slices is done by eroding segmentation of previous slices. The user also initializes the boundary points for every slice. A combination of changes in the modified Hausdorff distance (MHD) between contours at successive iterations and a stopping boundary formed from initial boundary points is used as a stopping criterion to avoid over- or under-segmentation The proposed algorithm is evaluated against manually segmented boundaries by calculating dice similarity coefficient (DSC), HD and MHD in the common carotid (C), carotid bulb (B) and internal carotid (I) regions to get a better understanding of accuracy?. Results from five subjects with >50% carotid stenosis showed good agreement with manual segmentation; between the semiautomatic algorithm & manuals: DSC (C: 86.49 +/- 9.38, B: 82.21 +/- 8.49, I: 78.96 +/- 7.55), MHD (C: 3.79 +/- 1.64, B: 4.09 +/- 1.71, I: 4.12 +/- 2.01), HD (C: 8.07 +/- 2.59, B: 10.09 +/- 3.95, I: 11.28 +/- 5.06); and inter observers: DSC (C: 88.31 +/- 5, B: 82.45 +/- 7.57, I: 82.03 +/- 8.83), MHD (C: 3.77 +/- 2.09, B: 4.32 +/- 1.88, I: 4.56 +/- 2.24), HD (C: 7.61 +/- 2.67, B: 10.22 +/- 4.30, I: 10.63 +/- 4.94). This method is a first step towards achieving full 3D characterization of plaque progression, and is currently being evaluated in a longitudinal study of asymptomatic carotid stenosis
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Semiautomatic Quantification of Carotid Plaque Volume With 3D Ultrasonography
    Lal, Brajesh K.
    Khan, Amir A.
    Koudelka, Christian
    Zhao, Limin
    Dux, Moira
    Goldstein, Carly B.
    JOURNAL OF VASCULAR SURGERY, 2016, 63 (06) : 186S - 186S
  • [42] Inter-rater Agreement in Carotid Atherosclerotic Plaque Evaluation by 3D Ultrasound
    Bar, M.
    Roubec, M.
    Farana, R.
    Licev, L.
    Skoloudik, D.
    CEREBROVASCULAR DISEASES, 2013, 35 : 390 - 390
  • [43] Lumen segmentation in magnetic resonance images of the carotid artery
    Jodas, Danilo Samuel
    Pereira, Aledir Silveira
    Tavares, Joao Manuel R. S.
    COMPUTERS IN BIOLOGY AND MEDICINE, 2016, 79 : 233 - 242
  • [44] Estimating 3D lumen centerlines of carotid arteries in free-hand acquisition ultrasound
    Diego D. B. Carvalho
    Stefan Klein
    Zeynettin Akkus
    Gerrit L. ten Kate
    Arend F. L. Schinkel
    Johan G. Bosch
    Aad van der Lugt
    Wiro J. Niessen
    International Journal of Computer Assisted Radiology and Surgery, 2012, 7 : 207 - 215
  • [45] Estimating 3D lumen centerlines of carotid arteries in free-hand acquisition ultrasound
    Carvalho, Diego D. B.
    Klein, Stefan
    Akkus, Zeynettin
    ten Kate, Gerrit L.
    Schinkel, Arend F. L.
    Bosch, Johan G.
    van der Lugt, Aad
    Niessen, Wiro J.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2012, 7 (02) : 207 - 215
  • [46] Automated Lumen Segmentation in Carotid Artery Ultrasound Images Based on Adaptive Generated Shape Prior
    Li, Yu
    Zou, Liwen
    Song, Jiajia
    Gong, Kailin
    BIOENGINEERING-BASEL, 2024, 11 (08):
  • [47] Efficient semiautomatic segmentation of 3D objects in medical images
    Schenk, A
    Prause, G
    Peitgen, HO
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2000, 2000, 1935 : 186 - 195
  • [48] A novel automatic algorithm for the segmentation of the lumen of the carotid artery in ultrasound B-mode images
    Santos, Andre Miguel F.
    dos Santos, Rosa Maria
    Castro, Pedro Miguel A. C.
    Azevedo, Elsa
    Sousa, Luisa
    Tavares, Joao Manuel R. S.
    EXPERT SYSTEMS WITH APPLICATIONS, 2013, 40 (16) : 6570 - 6579
  • [49] Three-dimensional (3D) ultrasound imaging of carotid web
    Binyang Gao
    Yan Luo
    Chenyun Zhou
    Mei Zhang
    Xiaorong Wen
    Acta Neurologica Belgica, 2023, 123 : 1159 - 1160
  • [50] Three-dimensional (3D) ultrasound imaging of carotid web
    Gao, Binyang
    Luo, Yan
    Zhou, Chenyun
    Zhang, Mei
    Wen, Xiaorong
    ACTA NEUROLOGICA BELGICA, 2023, 123 (03) : 1159 - 1160