Hygrothermal performance of cross-laminated timber wall assemblies with built-in moisture: field measurements and simulations

被引:81
|
作者
McClung, Ruth [1 ]
Ge, Hua [2 ]
Straube, John [3 ]
Wang, Jieying [4 ]
机构
[1] Morrison Hershfield, Vancouver, BC, Canada
[2] Concordia Univ, Montreal, PQ H3G 1M8, Canada
[3] Univ Waterloo, Waterloo, ON N2L 3G1, Canada
[4] FPInnovations, Vancouver, BC V6T 1Z4, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Cross-laminated timber (CLT) wall assemblies; Hygrothermal performance; Field test; Moisture content; Wood; Hygrothermal simulations;
D O I
10.1016/j.buildenv.2013.09.008
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Cross-laminated timber (CLT) panels have potential market in North America for building mid-rise or even taller structures due to their good structural and fire safety performance, light weight, and prefabricated nature. However, to ensure long-term durability when used in building enclosures, the hygrothermal performance of CLT wall assemblies needs to be evaluated in terms of wetting and drying potential. A test wall consisting of sixteen 0.6 m by 0.6 m CLT panels made of five different wood species (or species groups) and four different wall assemblies was constructed. The CLT panels were initially wetted with the moisture content (MC) in the surface layers approaching or exceeding 30%, and monitored for MCs and temperatures at different depths over one year in a building envelope test facility located in Waterloo, Ontario. The drying behaviour of these panels was analysed and the measured MCs over time were compared to simulation results using a commercial hygrothermal program. This field study showed that most of the CLT panels dried to below 26% within one month except for CLT walls with a low-permeance interior membrane, which indicated that none of the CLT walls would likely remain at a high MC level long enough to initiate decay under the conditions tested. The simulation results generally agree well with the field data at MCs below 26%. However, it was found that the hygrothermal simulation program tended to overestimate the MC in the centre of the panels by up to 5-10%, and simulated MCs at locations deep into the CLT panels were not as responsive to changes in ambient conditions, as the measurements indicated for assemblies with high exterior permeance. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:95 / 110
页数:16
相关论文
共 50 条
  • [31] Study on in-plane compressive performance of cross-laminated bamboo and timber (CLBT) wall elements
    Li, Hao
    Wang, Libin
    Wang, Brad Jianhe
    Wei, Yang
    EUROPEAN JOURNAL OF WOOD AND WOOD PRODUCTS, 2023, 81 (02) : 343 - 355
  • [32] Performance-based design of tall-coupled cross-laminated timber wall building
    Teweldebrhan, Biniam Tekle
    Tesfamariam, Solomon
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2022, 51 (07): : 1677 - 1696
  • [33] Bonding performance of cross-laminated timber-bamboo composites
    Dong, Weiqun
    Wang, Zhiqiang
    Chen, Guojun
    Wang, Yi
    Huang, Qianzhi
    Gong, Meng
    JOURNAL OF BUILDING ENGINEERING, 2023, 63
  • [34] PERFORMANCE EVALUATION OF THE BENDING STRENGTH OF LARCH CROSS-LAMINATED TIMBER
    Song, Yo-Jin
    Hong, Soon-Il
    WOOD RESEARCH, 2018, 63 (01) : 105 - 115
  • [35] Strain variation analysis of cross-laminated timber elements under cyclic moisture
    Silva, Catarina
    Branco, Jorge M.
    Mehdipour, Zabih
    Xavier, Jose
    Reboucas, Arthur S.
    Lourenco, Paulo B.
    JOURNAL OF BUILDING ENGINEERING, 2021, 41
  • [36] Enhancing indoor comfort and building energy efficiency with cross-laminated timber (CLT) in hygrothermal environments
    Kang, Yujin
    Jo, Ho Hyeon
    Kim, Sumin
    JOURNAL OF BUILDING ENGINEERING, 2024, 84
  • [37] Experimental Stress Analysis of Cross-Laminated Timber Elements under Cyclic Moisture
    Silva, Catarina
    Branco, Jorge M.
    Mehdipour, Zabih
    Xavier, Jose
    Lourenco, Paulo B.
    JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2022, 34 (08)
  • [38] Bending and shear performance of cross-laminated timber and glued-laminated timber beams: A comparative investigation
    Li, Hao
    Wang, Libin
    Wei, Yang
    Wang, Brad Jianhe
    Jin, Hui
    JOURNAL OF BUILDING ENGINEERING, 2022, 45
  • [39] Dry-out behaviour of cross-laminated timber (CLT) edge conditions in roof assemblies: A field study
    Johns, Dorothy
    Richman, Russell
    STRUCTURES, 2025, 72
  • [40] Fire resistance of unprotected cross-laminated timber (CLT) floor assemblies produced in the USA
    Muszynski, Lech
    Gupta, Rakesh
    Hong, Seung Hyun
    Osborn, Neil
    Pickett, Brent
    FIRE SAFETY JOURNAL, 2019, 107 : 126 - 136