Monte Carlo calculation of the ionization chamber response to 60Co beam using PENELOPE

被引:17
|
作者
Yi, Chul-Young
Hah, Suck-Ho
Yeom, Min Sun
机构
[1] Korea Res Inst Stand & Sci, Ionizing Radiat Grp, Taejon 305600, South Korea
[2] Korea Inst Sci & Technol, Supercomp Ctr, Dept Supercomp Applicat & Technol, Taejon 305606, South Korea
关键词
Monte Carlo; PENELOPE; ion chamber; cavity dose; Co-60;
D O I
10.1118/1.2188822
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The calculation of the ionization chamber response is one of key factors to develop a primary standard of air kerma. Using Monte Carlo code PENELOPE, we simulated the cavity response of the plane parallel ionization chamber to the monoenergetic Co-60 beam incident normally on a flat surface of the chamber. Two simulation techniques, namely, the uniform interaction technique and the reentrance technique, were introduced. The effect of the input parameters such as C1 (average angular deflection in a single step between hard elastic events), C2 (maximum average fractional energy loss in a step), s(max) (maximum step length) and W-cc (the lower energy of secondary electrons created as a result of a hard collision) on the simulated cavity dose was evaluated. We found that the simulated cavity response of the graphite and solid air chambers obtained by PENELOPE to the monoenergetic Co-60 beam could be consistent with the value expected from the cross-sections of PENELOPE to within 0.2% (one standard deviation) when W-cc and s(max) were selected carefully. (c) 2006 American Association of Physicists in Medicine.
引用
收藏
页码:1213 / 1221
页数:9
相关论文
共 50 条
  • [21] MONTE-CARLO SIMULATION OF A CO-60 BEAM
    HAN, K
    BALLON, D
    CHUI, C
    MOHAN, R
    MEDICAL PHYSICS, 1987, 14 (03) : 414 - 419
  • [22] Electron beam quality correction factors for plane-parallel ionization chambers: Monte Carlo calculations using the PENELOPE system
    Sempau, J
    Andreo, P
    Aldana, J
    Mazurier, J
    Salvat, F
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (18): : 4427 - 4444
  • [23] Comparison of doses calculated by the Monte Carlo method and measured by Lif TLD in the buildup region for a 60Co photon beam
    Budanec, M.
    Knezevic, Z.
    Bokulic, T.
    Mrcela, I.
    Vrtar, M.
    Vekic, B.
    Kusic, Z.
    APPLIED RADIATION AND ISOTOPES, 2008, 66 (12) : 1925 - 1929
  • [24] MONTE-CARLO CALCULATION OF IONIZATION PROFILE DUE TO ELECTRON-BEAM IN CO-HE SYSTEM
    WU, FT
    LUNDSTR, EA
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1975, 20 (02): : 235 - 235
  • [25] Simulation of the response of the IG11 4πγ ionization chamber using GEANT Monte Carlo code
    Gostely, JJ
    Laedermann, JP
    APPLIED RADIATION AND ISOTOPES, 2000, 52 (03) : 447 - 453
  • [26] Optimal design of 60Co single source radiation facility with Monte Carlo method
    Xiao, X.-F. (xiaoxue9420_cn@sina.com), 1600, Atomic Energy Press (48):
  • [27] Analyzing the transient effects of 60Co gamma rays in a CIS by Monte Carlo method
    Xue, Yuan-Yuan
    Wang, Zu-Jun
    Liu, Min-Bo
    Xu, Rui
    Ning, Hao
    Zhao, Wen
    He, Bao-Ping
    Yao, Zhi-Bin
    Sheng, Jiang-Kun
    Ma, Wu-Ying
    Dong, Guan-Tao
    NUCLEAR SCIENCE AND TECHNIQUES, 2019, 30 (07)
  • [28] Investigation of the air kerma response of spherical ionization chambers for unfolded pulse height distributions of 60CO and 137Cs using the EGS4 Monte Carlo code
    Chun, Kook Jin
    Yoo, Gwang Ho
    JOURNAL OF RADIATION RESEARCH, 2007, 48 (05) : 385 - 395
  • [29] Analyzing the transient effects of 60Co gamma rays in a CIS by Monte Carlo method
    Yuan-Yuan Xue
    Zu-Jun Wang
    Min-Bo Liu
    Rui Xu
    Hao Ning
    Wen Zhao
    Bao-Ping He
    Zhi-Bin Yao
    Jiang-Kun Sheng
    Wu-Ying Ma
    Guan-Tao Dong
    NuclearScienceandTechniques, 2019, 30 (07) : 55 - 61
  • [30] Monte Carlo Dosimetry of the 60Co Bebig High Dose Rate Source for Brachytherapy
    Campos, L. T.
    de Almeida, C. E. V.
    MEDICAL PHYSICS, 2016, 43 (06) : 3464 - 3464