A comparative study of three-dimensional high-definition and two-dimensional high-definition video systems in totally endoscopic mitral valve replacement

被引:10
|
作者
Zang, Xin [1 ]
Huang, Huan-Lei [1 ]
Xie, Bin [1 ]
Liu, Jian [1 ]
Guo, Hui-Ming [1 ]
机构
[1] Guangdong Acad Med Sci, Guangdong Prov Peoples Hosp, Guangdong Cardiovasc Inst, Dept Adult Cardiac Surg, Guangzhou 510080, Guangdong, Peoples R China
关键词
Imagine; three-dimensional (3D); minimally invasive surgery; surgery; thoracoscopic; mitral valve; SURGERY; 3D; VISUALIZATION; PERFORMANCE; LOBECTOMY; 2D;
D O I
10.21037/jtd.2019.02.27
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background: Three-dimensional vision with improved depth perception and spatial orientation has already proved its superiority to the two-dimensional vision in endoscopic surgery. However, those benefits remain unidentified in cardiac surgery. For the first time, we compare performance of a three-dimensional high-definition video system with a two-dimensional high-definition video system in patients undergoing totally endoscopic mitral valve replacement. Methods: We enrolled 90 patients with mitral valve disease in a single institution, from June 2013 to June 2016. Totally endoscopic mitral valve replacement was performed by the same surgeon using either a three-dimensional high-definition (n=43) or a two-dimensional high-definition (n=47) video system with the same surgical technique. Short-term outcomes were compared between the two groups. All medical records were retrieved from a prospectively maintained database of minimally invasive cardiac surgery. Results: All surgeries were successfully completed under totally endoscopic guidance. There were no intraoperative complications in either group. The use of three-dimensional video system reduced aortic cross-clamp time by approximately 10% (3D vs. 2D: 65.74 +/- 14.32 vs. 72.67 +/- 14.67 min, P=0.027). No significant differences were observed in cardiopulmonary bypass time, postoperative ventilation duration, length of surgical intensive care unit stay, length of hospital stay, and major complications between the two groups. There were no perioperative deaths in either group. Conclusions: Compared with the two-dimensional video system, the three-dimensional high-definition video system provided a better surgical experience with the same operative safety for totally endoscopic mitral valve replacement.
引用
收藏
页码:788 / 794
页数:7
相关论文
共 50 条
  • [31] : High-definition three-dimensional flow imaging in prenatal diagnosis of velamentous umbilical cord insertion
    Rodriguez, N.
    Suarez, N.
    Vasquez, A.
    Cantor, N.
    Rodriguez, N.
    Esquivel, A. L.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2023, 62 : 204 - 204
  • [32] Three-dimensional, high-definition exoscopic parotidectomy: a valid alternative to magnified-assisted surgery
    Carta, F.
    Mariani, C.
    Marrosu, V.
    Gerosa, C.
    Puxeddu, R.
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2020, 58 (09): : 1128 - 1132
  • [33] Diagnosis of interstitial ectopic pregnancy using a three-dimensional high-definition live rendering image
    Jiang, Ling-Yu
    Wang, Peng-Hui
    Lee, Hsing-Yang
    Chen, Chih-Yao
    TAIWANESE JOURNAL OF OBSTETRICS & GYNECOLOGY, 2015, 54 (04): : 465 - 466
  • [34] Three-dimensional high-definition flow imaging in prenatal diagnosis of a true umbilical cord knot
    Rodriguez, N.
    Angarita, A. M.
    Casasbuenas, A.
    Sarmiento, A.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2012, 39 (02) : 245 - 246
  • [35] Use of a compact high-definition two-dimensional exoscope in surgical treatment of large vestibular schwannoma
    Chen, Xin
    Gao, Xiang-Liang
    Chai, Yan
    Shi, Ming-Ming
    Zhang, Jian-Ning
    Yue, Shu-Yuan
    CHINESE MEDICAL JOURNAL, 2020, 133 (11) : 1292 - 1297
  • [36] TECHNICAL CONSIDERATIONS FOR CARDIAC LABORATORY HIGH-DEFINITION VIDEO SYSTEMS
    GRAY, JE
    WONDROW, MA
    SMITH, HC
    HOLMES, DR
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1984, 10 (01): : 73 - 86
  • [37] Use of a compact high-definition two-dimensional exoscope in surgical treatment of large vestibular schwannoma
    Chen Xin
    Gao Xiang-Liang
    Chai Yan
    Shi Ming-Ming
    Zhang Jian-Ning
    Yue Shu-Yuan
    中华医学杂志英文版, 2020, 133 (11) : 1292 - 1297
  • [38] A comparison of laparoscopic procedures performed by novice medical students using 8K ultra-high-definition/two-dimensional and 2K high-definition/three-dimensional monitors
    Shonaka, Tatsuya
    Tani, Chikayoshi
    Iwata, Hiroyoshi
    Otani, Masahide
    Hasegawa, Kimiharu
    Matsuno, Naoto
    Furukawa, Hiroyuki
    Yoshida, Akitoshi
    Sumi, Yasuo
    SURGERY TODAY, 2021, 51 (08) : 1397 - 1403
  • [39] A comparison of laparoscopic procedures performed by novice medical students using 8K ultra-high-definition/two-dimensional and 2K high-definition/three-dimensional monitors
    Tatsuya Shonaka
    Chikayoshi Tani
    Hiroyoshi Iwata
    Masahide Otani
    Kimiharu Hasegawa
    Naoto Matsuno
    Hiroyuki Furukawa
    Akitoshi Yoshida
    Yasuo Sumi
    Surgery Today, 2021, 51 : 1397 - 1403
  • [40] Feasibility of IAPWG protocol in performing high-definition three-dimensional anorectal manometry: A prospective, multicentric italian study
    Della Casa, D.
    Lambiase, C.
    Origi, M.
    Battaglia, L.
    Guaglio, M.
    Cataudella, G.
    Dell'Era, A.
    Bellini, M.
    TECHNIQUES IN COLOPROCTOLOGY, 2024, 28 (01)