A fast and sensitive immunoassay of avian influenza virus based on label-free quantum dot probe and lateral flow test strip

被引:82
|
作者
Li, Xuepu [1 ]
Lu, Donglian [1 ]
Sheng, Zonghai [1 ]
Chen, Kun [1 ]
Guo, Xuebo [2 ]
Jin, Meilin [2 ]
Han, Heyou [1 ]
机构
[1] Huazhong Normal Univ, Coll Sci, State Key Lab Agr Microbiol, Wuhan 430070, Peoples R China
[2] Huazhong Agr Univ, State Key Lab Agr Microbiol, Unit Anim Infect Dis, Wuhan 430070, Peoples R China
基金
中国国家自然科学基金;
关键词
Quantum dots; Fluorescence immunoassay; Signal amplification; Avian influenza virus; Lateral flow test strip; LINKED-IMMUNOSORBENT-ASSAY; ELECTROCHEMICAL IMMUNOSENSOR; IMMUNOCHROMATOGRAPHIC STRIP; RAPID DETECTION; H5; ELISA; ANTIBODIES; BIOSENSOR; DIAGNOSIS; H7;
D O I
10.1016/j.talanta.2012.08.041
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel fluorescence immunoassay method for fast and ultrasensitive detection of avian influenza virus (AIV) was developed. The immunoassay method which integrated lateral flow test strip technique with fluorescence immunoassay used the label-free and high luminescent quantum dots (QDs) as signal output. By the sandwich immunoreaction performed on lateral flow test strip, the gold nanoparticle (NP) labels were captured in the test zone and further dissolved to release a large number of gold ions as a signal transduction bridge that was detected by the QDs-based fluorescence quenching method. Under the optimal conditions, the relative fluorescence intensity of QDs was linear over the range of 0.27-12 ng mL(-1) AIV, and the limit of detection was estimated to be 0.09 ng mL(-1) which was 100-fold greater than enzyme-linked immunosorbent assay (ELISA). The sensitive and specific response was also coupled with high reproducibility in the proposed method. A series of six parallel measurements produced reproducible fluorescent signals with a relative standard deviation of 4.7%. The proposed method can be used to directly detect clinical sample without any pretreatment, and showed high efficiency (90.0%), sensitivity (100.0%) and specificity (88.2%) compared with virus isolation (gold method). The new method shows great promise for rapid, sensitive, and quantitative detection of AIV in-field or point-of-care diagnosis. Crown Copyright (C) 2012 Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 6
页数:6
相关论文
共 50 条
  • [41] Dielectrically-Modulated GANFET Biosensor for Label-Free Detection of DNA and Avian Influenza Virus: Proposal and Modeling
    Yadav, Shivani
    Das, Amit
    Rewari, Sonam
    ECS JOURNAL OF SOLID STATE SCIENCE AND TECHNOLOGY, 2024, 13 (04)
  • [42] Label-free sensitive detection of influenza virus using PZT discs with a synthetic sialylglycopolymer receptor layer
    Erofeev, Alexander S.
    Gorelkin, Petr, V
    Kolesov, Dmitry, V
    Kiselevs, Gleb A.
    Dubrovin, Evgeniy, V
    Yaminsky, Igor, V
    ROYAL SOCIETY OPEN SCIENCE, 2019, 6 (09):
  • [43] Development of label-free optical diagnosis for sensitive detection of influenza virus with genetically engineered fusion protein
    Park, Tae Jung
    Lee, Seok Jae
    Kim, Do-Kyun
    Heo, Nam Su
    Park, Jung Youn
    Lee, Sang Yup
    TALANTA, 2012, 89 : 246 - 252
  • [44] Rapid and Label-Free Detection of Influenza A Virus With a SAW Biosensor Based on DNA Probes
    Sun, Huimin
    Tao, Ye
    Li, Yongchun
    Wang, Mengye
    Wang, Hong
    IEEE SENSORS JOURNAL, 2024, 24 (11) : 17570 - 17578
  • [45] A novel lateral flow immunoassay strip based on a label-free magnetic Fe3O4@UiO-66-NH2 nanocomposite for rapid detection of Listeria monocytogenes
    Du, Juan
    Liu, Kai
    Liu, Jialei
    Zhao, Dianbo
    Bai, Yanhong
    ANALYTICAL METHODS, 2022, 14 (24) : 2423 - 2430
  • [46] A new immunoassay of serum antibodies against Peste des petits ruminants virus using quantum dots and a lateral-flow test strip
    Si Cheng
    Jie Sun
    Junxing Yang
    Jianqiang Lv
    Feng Wu
    Yanxing Lin
    Lishan Liao
    Yiyou Ye
    Chenfu Cao
    Liurong Fang
    Qunyi Hua
    Analytical and Bioanalytical Chemistry, 2017, 409 : 133 - 141
  • [47] A new immunoassay of serum antibodies against Peste des petits ruminants virus using quantum dots and a lateral-flow test strip
    Cheng, Si
    Sun, Jie
    Yang, Junxing
    Lv, Jianqiang
    Wu, Feng
    Lin, Yanxing
    Liao, Lishan
    Ye, Yiyou
    Cao, Chenfu
    Fang, Liurong
    Hua, Qunyi
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2017, 409 (01) : 133 - 141
  • [48] Quantitative and rapid detection of C-reactive protein using quantum dot-based lateral flow test strip
    Wu, Ruili
    Zhou, Shuai
    Chen, Ting
    Li, Jinjie
    Shen, Huaibin
    Chai, Yujuan
    Li, Lin Song
    ANALYTICA CHIMICA ACTA, 2018, 1008 : 1 - 7
  • [49] A simple and sensitive label-free fluorescent approach for protein detection based on a Perylene probe and aptamer
    Lv, Zhenzhen
    Liu, Jinchuan
    Bai, Wenhui
    Yang, Shuming
    Chen, Ailiang
    BIOSENSORS & BIOELECTRONICS, 2015, 64 : 530 - 534
  • [50] Lateral Flow Immunoassay Based on Quantum-Dot Nanobeads for Detection of Chloramphenicol in Aquatic Products
    Han, Qian
    Fan, Ling
    Liu, Xiuying
    Tang, Yiwei
    Wang, Pingping
    Shu, Zaixi
    Zhang, Wei
    Zhu, Lijie
    Critchley, Kevin
    MOLECULES, 2023, 28 (22):