Lacunarity analysis of spatial pattern in CT images of vertebral trabecular bone for assessing osteoporosis

被引:50
|
作者
Dougherty, G
Henebry, GM
机构
[1] Kuwait Univ, Fac Allied Hlth Sci, Dept Radiol Sci, Kuwait, Kuwait
[2] Univ Nebraska, Ctr Adv Land Management Informat Technol, Lincoln, NE 68588 USA
关键词
lacunarity; texture; bone quality; trabecular bone; computed tomography;
D O I
10.1016/S1350-4533(01)00106-0
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The structural integrity of vertebral trabecular bone is determined by the continuity of its trabecular network and the size of the holes comprising its marrow space, both of which determine the apparent size of the marrow spaces in a transaxial CT image. A model-independent assessment of the trabeculation pattern was determined from the lacunarity of thresholded CT images. Using test images of lumbar vertebrae from human cadavers, acquired at different slice thicknesses, we determined that both median thresholding and local adaptive thresholding (using a 7x7 window) successfully segmented the grey-scale images. Lacunarity analysis indicated a multifractal nature to the images, and a range of marrow space sizes with significant structure around 14-18 mm(2). Preliminary studies of in vivo images from a clinical CT scanner indicate that lacunarity analysis can follow the pattern of bone loss in osteoporosis by monitoring the homogeneity of the marrow spaces, which is related to the connectivity of the trabecular bone network and the marrow space sizes. Although the patient sample was small, derived parameters such as the maximum deviation of the lacunarity from a neutral (fractal) model, and the maximum derivative of this deviation, seem to be sufficiently sensitive to distinguish a range of bone conditions. Our results suggest that these parameters, used with bone mineral density values, may have diagnostic value in characterizing osteoporosis and predicting fracture risk. (C) 2002 IPEM. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:129 / 138
页数:10
相关论文
共 50 条
  • [31] CT and MR for bone mineral density and trabecular bone score assessment in osteoporosis evaluation
    Haein Lee
    Sunghoon Park
    Kyu-Sung Kwack
    Jae Sung Yun
    Scientific Reports, 13
  • [32] Topological analysis of trabecular bone MR images
    Gomberg, BR
    Saha, PK
    Song, HK
    Hwang, SN
    Wehrli, FW
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (03) : 166 - 174
  • [33] Influence of segmentation on micro-CT images of trabecular bone
    Tassani, S.
    Korfiatis, V.
    Matsopoulos, G. K.
    JOURNAL OF MICROSCOPY, 2014, 256 (02) : 75 - 81
  • [34] Assessments of trabecular bone density at implant sites on CT images
    Gomes de Oliveira, Rubelisa Candido
    Leles, Claudio Rodrigues
    Normanha, Leonardo Martins
    Lindh, Christina
    Ribeiro-Rotta, Rejane Faria
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2008, 105 (02): : 231 - 238
  • [35] Automatic thresholding of micro-CT trabecular bone images
    Zhang, Yongping
    He, Zhongkun
    Fan, Shaojing
    He, Kejia
    Li, Chen
    BMEI 2008: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS, VOL 2, 2008, : 23 - +
  • [36] Optimal sample volumes of human trabecular bone in μCT analysis within vertebral body and femoral head
    Wen, Xin-Xin
    Zong, Chun-Lin
    Xu, Chao
    Ma, Xiang-Yu
    Wang, Fa-Qi
    Feng, Ya-Fei
    Yan, Ya-Bo
    Lei, Wei
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2015, 8 (10): : 17868 - 17879
  • [37] CT IMAGE-ANALYSIS OF THE VERTEBRAL TRABECULAR NETWORK INVIVO
    CHEVALIER, F
    LAVALJEANTET, AM
    LAVALJEANTET, M
    BERGOT, C
    CALCIFIED TISSUE INTERNATIONAL, 1992, 51 (01) : 8 - 13
  • [38] VERTEBRAL TRABECULAR BONE - COMPARISON OF SINGLE AND DUAL-ENERGY CT MEASUREMENTS WITH CHEMICAL-ANALYSIS
    BURGESS, AE
    COLBORNE, B
    ZOFFMANN, E
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1987, 11 (03) : 506 - 515
  • [39] Quantitative CT in the measurement of bone quantity and bone quality for assessing osteoporosis
    Dougherty, G
    MEDICAL ENGINEERING & PHYSICS, 1996, 18 (07) : 557 - 568
  • [40] Quantitative CT in the measurement of bone quantity and bone quality for assessing osteoporosis
    Dougherty, G.
    Medical Engineering and Physics, 1996, 18 (07): : 557 - 568