Lacunarity analysis of spatial pattern in CT images of vertebral trabecular bone for assessing osteoporosis

被引:50
|
作者
Dougherty, G
Henebry, GM
机构
[1] Kuwait Univ, Fac Allied Hlth Sci, Dept Radiol Sci, Kuwait, Kuwait
[2] Univ Nebraska, Ctr Adv Land Management Informat Technol, Lincoln, NE 68588 USA
关键词
lacunarity; texture; bone quality; trabecular bone; computed tomography;
D O I
10.1016/S1350-4533(01)00106-0
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The structural integrity of vertebral trabecular bone is determined by the continuity of its trabecular network and the size of the holes comprising its marrow space, both of which determine the apparent size of the marrow spaces in a transaxial CT image. A model-independent assessment of the trabeculation pattern was determined from the lacunarity of thresholded CT images. Using test images of lumbar vertebrae from human cadavers, acquired at different slice thicknesses, we determined that both median thresholding and local adaptive thresholding (using a 7x7 window) successfully segmented the grey-scale images. Lacunarity analysis indicated a multifractal nature to the images, and a range of marrow space sizes with significant structure around 14-18 mm(2). Preliminary studies of in vivo images from a clinical CT scanner indicate that lacunarity analysis can follow the pattern of bone loss in osteoporosis by monitoring the homogeneity of the marrow spaces, which is related to the connectivity of the trabecular bone network and the marrow space sizes. Although the patient sample was small, derived parameters such as the maximum deviation of the lacunarity from a neutral (fractal) model, and the maximum derivative of this deviation, seem to be sufficiently sensitive to distinguish a range of bone conditions. Our results suggest that these parameters, used with bone mineral density values, may have diagnostic value in characterizing osteoporosis and predicting fracture risk. (C) 2002 IPEM. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:129 / 138
页数:10
相关论文
共 50 条
  • [1] Medical imaging and osteoporosis: Fractal's lacunarity analysis of trabecular bone in MR images
    Zaia, A
    Eleonori, R
    Maponi, P
    Rossi, R
    Murri, R
    18TH IEEE SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS, PROCEEDINGS, 2005, : 3 - 8
  • [2] MR imaging and osteoporosis: Fractal lacunarity analysis of trabecular bone
    Zaia, Annamaria
    Eleonori, Roberta
    Maponi, Pierluigi
    Rossi, Roberto
    Muni, Roberto
    IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2006, 10 (03): : 484 - 489
  • [3] Fractal signature and lacunarity in the measurement of the texture of trabecular bone in clinical CT images
    Dougherty, G
    Henebry, GM
    MEDICAL ENGINEERING & PHYSICS, 2001, 23 (06) : 369 - 380
  • [4] Vertebral osteoporosis and trabecular bone quality
    Mc Donnell, P.
    Mc Hugh, P. E.
    O' Mahoney, D.
    ANNALS OF BIOMEDICAL ENGINEERING, 2007, 35 (02) : 170 - 189
  • [5] Vertebral Osteoporosis and Trabecular Bone Quality
    P. Mc Donnell
    P. E. Mc Hugh
    D. O’ Mahoney
    Annals of Biomedical Engineering, 2007, 35 : 170 - 189
  • [6] A comparison of the texture of computed tomography and projection radiography images of vertebral trabecular bone using fractal signature and lacunarity
    Dougherty, G
    MEDICAL ENGINEERING & PHYSICS, 2001, 23 (05) : 313 - 321
  • [7] Lacunarity analysis of spatial pattern: A comparison
    M.R.T. Dale
    Landscape Ecology, 2000, 15 : 467 - 478
  • [8] Lacunarity analysis of spatial pattern: A comparison
    Dale, MRT
    LANDSCAPE ECOLOGY, 2000, 15 (05) : 467 - 478
  • [9] The nature of changes in vertebral body trabecular bone in osteoporosis
    Boyde, A
    BONE, 2001, 28 (05) : S177 - S177
  • [10] Fourier analysis reveals altered trabecular bone pattern in osteoporosis.
    Faber, TD
    Yoon, DC
    White, SC
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : A179 - A179