摘要
The atmospheric temperature is an important meteorological parameter. The rotational Raman lidar temperature measurement system is usually used for retrieval of atmospheric temperature according to the echo signal intensity ratio. UV double grating monochromator (DGM) is a kind of spectroscopical equipment for extracting the rotational Raman's spectra. The UV DGM consists of optical fibers, focal plates, lenses and gratings. Correct parameters of the gratings, lenses, fibers are essential to the successful development of DGM. First, a suitable grating is selected according to the grating diffraction theory. Second, the diameter and focal length of lens are chosen according to ruled area and blaze angle of grating, the numerical aperture of fiber and how difficult machining is. Finally, the range of fiber core diameter is chosen according to the distance between the sixth and the twelfth spectral line on the focal plane. In order to compare the different fiber core diameter's statistical temperature error, and suppression ratio of elastic scattering light, some numerical calculations are conducted. The simulation results show that the measurement accuracy increases in the evening and approximately decreases during daytime with the increase of input fiber core diameter. As the input fiber core diameter increases, the rejection ratio is decreasing, but they are all more than 7 orders of magnitude. It is preferable to choose input fiber with core diameter of 300um during the daytime and 600um at night. The correct parameters of grating, lens and fiber provide theoretical basis for the development of the UV DGM.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Pure rotational Raman lidar for accurate profiling of atmospheric temperature and aerosol/cloud backscatter coefficients
    Yi, Fan
    Yu, Changming
    Zhang, Yunpeng
    Liu, Fuchao
    Yi, Yang
    He, Yun
    Yin, Zhenping
    Zhou, Jun
    OPTICS EXPRESS, 2024, 32 (26): : 45566 - 45581
  • [32] ATMOSPHERIC-TEMPERATURE PROFILES FROM LIDAR MEASUREMENTS OF ROTATIONAL RAMAN AND ELASTIC-SCATTERING
    COHEN, A
    COONEY, JA
    GELLER, KN
    APPLIED OPTICS, 1976, 15 (11): : 2896 - 2901
  • [33] High-precision measurements of lower atmospheric temperature based on pure rotational Raman lidar
    Li Ya-Juan
    Song Sha-Lei
    Li Fa-Quan
    Cheng Xue-Wu
    Chen Zhen-Wei
    Liu Lin-Mei
    Yang Yong
    Gong Shun-Sheng
    CHINESE JOURNAL OF GEOPHYSICS-CHINESE EDITION, 2015, 58 (07): : 2294 - 2305
  • [34] Cloud temperature measurement using rotational Raman lidar
    Su, Jia
    McCormick, M. Patrick
    Wu, Yonghua
    Lee, Robert B., III
    Lei, Liqiao
    Liu, Zhaoyan
    Leavor, Kevin R.
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2013, 125 : 45 - 50
  • [35] Airborne compact rotational Raman lidar for temperature measurement
    Wu, Decheng
    Wang, Zhien
    Wechsler, Perry
    Mahon, Nick
    Deng, Min
    Glover, Brent
    Burkhart, Matthew
    Kuestner, William
    Heesen, Ben
    OPTICS EXPRESS, 2016, 24 (18): : A1210 - A1223
  • [36] Rotational Raman Lidar: Design and performance test of meteorological parameters (Aerosol backscattering coefficients and temperature)
    Kim, Dukyheon
    Cha, Hyungki
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2007, 51 (01) : 352 - 357
  • [37] ROTATIONAL RAMAN-SCATTERING SPECTRA IN NITROGEN AND OXYGEN AND APPLICATION IN LIDAR MEASUREMENT OF THE ATMOSPHERIC-TEMPERATURE
    MITEV, VM
    SIMEONOV, VB
    GRIGOROV, IV
    RECENT DEVELOPMENTS IN MOLECULAR SPECTROSCOPY, 1989, : 639 - 653
  • [38] Single-line-extracted pure rotational Raman lidar to measure atmospheric temperature and aerosol profiles
    Weng, Miao
    Yi, Fan
    Liu, Fuchao
    Zhang, Yunpeng
    Pan, Xiangliang
    OPTICS EXPRESS, 2018, 26 (21): : 27555 - 27571
  • [39] Double-Receiver-Based Pure Rotational Raman LiDAR for Measuring Atmospheric Temperature at Altitudes Between Near Ground and Up To 35 km
    Liu, Fuchao
    Yi, Fan
    Zhang, Yunpeng
    Yi, Yang
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2019, 57 (12): : 10301 - 10309
  • [40] Design and simulation of Raman lidar with small field of view for atmospheric temperature and humidity detection
    Xu B.
    Han Y.
    Xu W.
    Zheng J.
    Sun D.
    Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2021, 50 (09):