Classification and energy analysis of bank building stock: A case study in Curitiba, Brazil

被引:9
|
作者
Wong, Ing Liang [1 ]
Kruger, Eduardo [2 ]
Menoncin Loper, Ana Claudia [2 ]
Mori, Fabiano Kiyoshi [3 ]
机构
[1] Glasgow Caledonian Univ, Sch Comp Engn & Built Environm, 70 Cowcaddens Rd, Glasgow G4 0BA, Lanark, Scotland
[2] Univ Tecnol Fed Parana UTFPR, Sede Ecoville, Dept Construcao Civil, Campus Curitiba, BR-81280340 Curitiba, Parana, Brazil
[3] Gerencia Filial Logist Curitiba GILOG CT, Caixa Econ Fed, Rua Jose Loureiro 195, BR-80010000 Curitiba, Parana, Brazil
关键词
building typology; classification; energy benchmarking; bottom-up approach; archetype technique; energy use intensity; BOTTOM-UP; SCHOOL BUILDINGS; CONSUMPTION; PERFORMANCE; BENCHMARKING; METHODOLOGY; MODELS; SECTOR; EFFICIENCY; SCENARIOS;
D O I
10.1016/j.jobe.2019.02.003
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
An engineering bottom-up technique has been selected for classification and energy analysis of 72 bank branches in the Brazilian city of Curitiba. A multi-stage approach has been adopted in this study to collect and analyse the dataset of these bank branches, virtually survey and map geometrical and design parameters of the branches and classify them according to shapes, sizes, geographical layout, and construction age. Four types (Type A to D) of bank branches have been identified. Type A branches have the greatest mean conditioned floor area (over 100 m(2)) with largest deviation of energy use intensity (over 47 kWh/m(2)year). Type B branches are most commonly found in densely populated downtown area. However, over 61% of the branches belong to Type C and D, which are mostly located in less congested sub-urban areas. The study also shows that post-2010s branches are among the largest energy consumers. An in-depth parametric assessment on specific design details from architectural drawings of selected branches was further conducted to identify the effects of building parameters on energy consumption of the bank branches. Despite the minute correlation obtained between energy consumption and design variables (R-2 of 0.253), a Linear Discriminant Analysis suggests that percentage of openings and occupant density are among the defining parameters of a low and medium-high consumer as regards bank branches in Brazil. This study provides insights into a better understanding of the design characteristics of bank branches in Curitiba and parameters potentially affecting their energy consumption. The archetype bottom-up technique presented in this study that involved studies at different stages can also be used to define typologies for other types of buildings. This study shows how complex building stock, such as, bank buildings could be classified and their energy performance collectively analysed using multi-stage approach. The approach combined a range of methods, which had been conducted in sequence, such as, virtual survey, building classification, further in-depth parametric and energy assessments of selected bank branches based on architectural drawings using Multiple Regression Analysis and Linear Discriminant Analysis. Such approach enables critical design parameters to be determined in the absence of complete set of building data, which could be adopted for other similar types of complex building stock.
引用
收藏
页码:259 / 269
页数:11
相关论文
共 50 条
  • [31] Impact of Rainwater Harvesting on the Drainage System: Case Study of a Condominium of Houses in Curitiba, Southern Brazil
    Teston, Andrea
    Teixeira, Celimar Azambuja
    Ghisi, Enedir
    Cardoso, Ernani Beninca
    WATER, 2018, 10 (08)
  • [32] China's building stock estimation and energy intensity analysis
    Huo, Tengfei
    Cai, Weiguang
    Ren, Hong
    Feng, Wei
    Zhu, Minglei
    Lang, Ningning
    Gao, Jingxin
    JOURNAL OF CLEANER PRODUCTION, 2019, 207 : 801 - 813
  • [33] Contact Center in a Smart Cities View: a Comparative Case Study of Curitiba (Brazil), Porto Alegre (Brazil) and Philadelphia (USA)
    Macadar, Marie Anne
    Lheureux-de-Freitas, Jorge
    de Azambuja, Luiza Schuch
    Luciano, Edimara Mezzomo
    9TH INTERNATIONAL CONFERENCE ON THEORY AND PRACTICE OF ELECTRONIC GOVERNANCE (ICEGOV 2016), 2016, : 215 - 222
  • [34] Energy refurbishment of the Italian residential building stock: energy and cost analysis through the application of the building typology
    Ballarini, Ilaria
    Corrado, Vincenzo
    Madonna, Francesco
    Paduos, Simona
    Ravasio, Franco
    ENERGY POLICY, 2017, 105 : 148 - 160
  • [35] Comparative analysis of the resource classification techniques: case study of the Conceicao Mine, Brazil
    de Souza, L.
    Costa, J.
    Koppe, J.
    TRANSACTIONS OF THE INSTITUTIONS OF MINING AND METALLURGY SECTION B-APPLIED EARTH SCIENCE, 2010, 119 (03): : 166 - 175
  • [36] Urban building energy modeling considering the heterogeneity of HVAC system stock: A case study on Japanese office building stock (vol 207, pg 547, 2019)
    Kim, Bumjoon
    Yamaguchi, Yohei
    Kimura, Shun
    Ko, Yumei
    Ikeda, Kosuke
    Shimoda, Yoshiyuki
    ENERGY AND BUILDINGS, 2020, 207
  • [37] On the energy performance of the Mediterranean school building stock: The case of the Apulia Region
    Campagna, Ludovica Maria
    Fiorito, Francesco
    ENERGY AND BUILDINGS, 2023, 293
  • [38] Boosting life sciences research in Brazil: building a case for a local Drosophila stock center
    Oliveira, Marcos T.
    Anhezini, Lucas
    Araujo, Helena M.
    Oliveira, Marcus F.
    Couto-Lima, Carlos A.
    GENETICS AND MOLECULAR BIOLOGY, 2024, 47 (01)
  • [39] Towards a calibration of building energy models: A case study from the Spanish housing stock in the Mediterranean climate
    Blazquez, T.
    Suarez, R.
    Sendra, J. J.
    INFORMES DE LA CONSTRUCCION, 2015, 67 (540)
  • [40] A bottom-up dynamic building stock model for residential energy transition: A case study for the Netherlands
    Yang, Xining
    Hu, Mingming
    Tukker, Arnold
    Zhang, Chunbo
    Huo, Tengfei
    Steubing, Bernhard
    APPLIED ENERGY, 2022, 306