Artifact Reduction in X-Ray CT Images of Al-Steel-Perspex Specimens Mimicking a Hip Prosthesis

被引:0
|
作者
Madhogarhia, Manish [1 ]
Munshi, P. [1 ]
Lukose, Sijo [2 ]
Subramanian, M. P. [2 ]
Muralidhar, C. [2 ]
机构
[1] Indian Inst Technol, Nucl Engn & Technol Programme, Kanpur 208016, Uttar Pradesh, India
[2] Def Res & Dev Lab, Non Destruct Evaluat Div, Hyderabad 500258, Andhra Pradesh, India
来源
关键词
X-ray CT; Beam hardening; Metal Artifacts; Inherent error;
D O I
暂无
中图分类号
O59 [应用物理学];
学科分类号
摘要
X-ray Computed Tomography (CT) is a relatively new technique developed in the late 1970's, which enables the nondestructive visualization of the internal structure of objects. Beam hardening caused by the polychromatic spectrum is all important problem in X-ray computed tomography (X-CT). It leads to various artifacts in reconstruction images and reduces image quality. In the present work we are considering the Artifact Reduction in Total Hip Prosthesis CT Scan which is a problem of medical imaging. We are trying to reduce the cupping artifact induced by beam hardening as well as metal artifact as they exist in the CT scan of a human hip after the femur is replaced by a metal implant. The correction method for beam hardening used here is based on a previous work. Simulation study for the present problem includes a phantom consisting of mild steel, aluminium and perspex mimicking the photon attenuation properties of a hum hip cross section with metal implant.
引用
收藏
页码:57 / +
页数:2
相关论文
共 50 条
  • [41] Combining iterative metal artifact reduction and virtual monoenergetic images severely reduces hip prosthesis-associated artifacts in photon-counting detector CT
    Layer, Yannik C.
    Mesropyan, Narine
    Kupczyk, Patrick A.
    Luetkens, Julian A.
    Isaak, Alexander
    Dell, Tatjana
    Attenberger, Ulrike I.
    Kuetting, Daniel
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [42] AN IMAGE-PROCESSING TECHNIQUE FOR THE IDENTIFICATION OF CONTACT PIXELS APPLIED TO X-RAY CT IMAGES OF IMPLANTED HIP PROSTHESES
    BERRY, E
    LANGKAMER, VG
    JACKSON, PC
    SNOW, M
    GODDARD, PR
    WELLS, PNT
    PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (02): : 323 - 328
  • [43] Joint metal artifact reduction and material discrimination in X-ray CT using a learning-based graph-cut method
    Martin, Limor
    Tuysuzoglu, Ahmet
    Ishwar, Prakash
    Karl, W. Clem
    COMPUTATIONAL IMAGING XII, 2014, 9020
  • [44] Metal artifact reduction in ultra-high-resolution cone-beam CT imaging with a twin robotic X-ray system
    Andreas Steven Kunz
    Theresa Sophie Patzer
    Jan-Peter Grunz
    Karsten Sebastian Luetkens
    Viktor Hartung
    Robin Hendel
    Tabea Fieber
    Franca Genest
    Süleyman Ergün
    Thorsten Alexander Bley
    Henner Huflage
    Scientific Reports, 12
  • [45] Metal artifact reduction in ultra-high-resolution cone-beam CT imaging with a twin robotic X-ray system
    Kunz, Andreas Steven
    Patzer, Theresa Sophie
    Grunz, Jan-Peter
    Luetkens, Karsten Sebastian
    Hartung, Viktor
    Hendel, Robin
    Fieber, Tabea
    Genest, Franca
    Erguen, Suleyman
    Bley, Thorsten Alexander
    Huflage, Henner
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [46] Dynamic re-weighted total variation technique and statistic iterative reconstruction method for x-ray CT metal artifact reduction
    Peng, Chengtao
    Qiu, Bensheng
    Zhang, Cheng
    Ma, Changyu
    Yuan, Gang
    Li, Ming
    NINTH INTERNATIONAL CONFERENCE ON DIGITAL IMAGE PROCESSING (ICDIP 2017), 2017, 10420
  • [47] Implicit neural representation-based method for metal-induced beam hardening artifact reduction in X-ray CT imaging
    Park, Hyoung Suk
    Seo, Jin Keun
    Jeon, Kiwan
    MEDICAL PHYSICS, 2025,
  • [48] A Single Material Beam Hardening Reduction Approach for Industrial X-ray CT Images Utilizing Convolutional Neural Network
    Ghafarzadeh, Mahdi
    Kejani, Mohammad Tavakoli
    Asadi, Amirreza
    Karimi, Mehdi
    e-Journal of Nondestructive Testing, 2024, 29 (03):
  • [49] Non-iterative Method for Metal Artifact Reduction by using a Linearized Beam-hardening Correction Model for Polychromatic X-ray CT
    Hur, Jin
    Kim, Dongjoon
    Lee, Sangchul
    Shin, Yeong-gil
    INTERNATIONAL FORUM ON MEDICAL IMAGING IN ASIA 2019, 2019, 11050
  • [50] BEAM HARDENING ARTIFACT REDUCTION IN X-RAY CT RECONSTRUCTION OF 3D PRINTED METAL PARTS LEVERAGING DEEP LEARNING AND CAD MODELS
    Ziabari, Amirkoushyar
    Venkatakrishnan, Singanallur
    Kirka, Michael
    Brackman, Paul
    Dehoff, Ryan
    Bingham, Philip
    Paquit, Vincent
    PROCEEDINGS OF THE ASME 2020 INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, IMECE2020, VOL 2B, 2020,