Artifact Reduction in X-Ray CT Images of Al-Steel-Perspex Specimens Mimicking a Hip Prosthesis

被引:0
|
作者
Madhogarhia, Manish [1 ]
Munshi, P. [1 ]
Lukose, Sijo [2 ]
Subramanian, M. P. [2 ]
Muralidhar, C. [2 ]
机构
[1] Indian Inst Technol, Nucl Engn & Technol Programme, Kanpur 208016, Uttar Pradesh, India
[2] Def Res & Dev Lab, Non Destruct Evaluat Div, Hyderabad 500258, Andhra Pradesh, India
来源
关键词
X-ray CT; Beam hardening; Metal Artifacts; Inherent error;
D O I
暂无
中图分类号
O59 [应用物理学];
学科分类号
摘要
X-ray Computed Tomography (CT) is a relatively new technique developed in the late 1970's, which enables the nondestructive visualization of the internal structure of objects. Beam hardening caused by the polychromatic spectrum is all important problem in X-ray computed tomography (X-CT). It leads to various artifacts in reconstruction images and reduces image quality. In the present work we are considering the Artifact Reduction in Total Hip Prosthesis CT Scan which is a problem of medical imaging. We are trying to reduce the cupping artifact induced by beam hardening as well as metal artifact as they exist in the CT scan of a human hip after the femur is replaced by a metal implant. The correction method for beam hardening used here is based on a previous work. Simulation study for the present problem includes a phantom consisting of mild steel, aluminium and perspex mimicking the photon attenuation properties of a hum hip cross section with metal implant.
引用
收藏
页码:57 / +
页数:2
相关论文
共 50 条
  • [1] Comparative Methods for Metal Artifact Reduction in x-ray CT
    Abdoli, Mehrsima
    Mehranian, Abolfazl
    Ailianou, Angeliki
    Becker, Minerva
    Zaidi, Habib
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [2] A hybrid metal artifact reduction algorithm for x-ray CT
    Zhang, Yanbo
    Yan, Hao
    Jia, Xun
    Yang, Jian
    Jiang, Steve B.
    Mou, Xuanqin
    MEDICAL PHYSICS, 2013, 40 (04)
  • [3] A quantitative evaluation of the hip prosthesis segmentation quality in X-ray images
    Oprea, Alina
    Vertan, Constantin
    ISSCS 2007: INTERNATIONAL SYMPOSIUM ON SIGNALS, CIRCUITS AND SYSTEMS, VOLS 1 AND 2, 2007, : 197 - +
  • [4] Metal Artifact Reduction in X-ray CT via Ray Profile Correction
    Ha, Sungsoo
    Mueller, Klaus
    APPLIED SCIENCES-BASEL, 2020, 10 (01):
  • [5] Fast iterative algorithm for metal artifact reduction in X-ray CT
    Wang, G
    Frei, T
    Vannier, MW
    ACADEMIC RADIOLOGY, 2000, 7 (08) : 607 - 614
  • [6] Multisource x-ray system for artifact reduction in dedicated breast CT
    Becker, Amy E.
    Hernandez, Andrew M.
    Schwoebel, Paul
    Boone, John M.
    14TH INTERNATIONAL WORKSHOP ON BREAST IMAGING (IWBI 2018), 2018, 10718
  • [7] Multisource X-Ray System for Artifact Reduction in Cone Beam CT
    Becker, A.
    Hernandez, A.
    Schwoebel, P.
    Boone, J.
    MEDICAL PHYSICS, 2017, 44 (06) : 3177 - 3178
  • [8] X-ray CT metal artifact reduction using wavelets: Arm application for imaging total hip prostheses
    Zhao, SY
    Roberston, DD
    Wang, G
    Whiting, B
    Bae, KT
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (12) : 1238 - 1247
  • [9] Metal Artifact Reduction by Direct Artifact Prediction using Deep Learning in X-ray CT
    Yamakawa, Keisuke
    Goto, Taiga
    Kudo, Masatoshi
    Aoki, Yuko
    Machida, Tadashi
    MEDICAL IMAGING 2022: PHYSICS OF MEDICAL IMAGING, 2022, 12031
  • [10] Development of a Multi-Axis X-ray CT for Metal Artifact Reduction
    Toru, Kano
    Koseki, Michihiko
    2018 57TH ANNUAL CONFERENCE OF THE SOCIETY OF INSTRUMENT AND CONTROL ENGINEERS OF JAPAN (SICE), 2018, : 1344 - 1349