Monte Carlo simulation of γ-ray spectra from natural radionuclides recorded by a NaI detector in the marine environment

被引:35
|
作者
Vlastou, R
Ntziou, IT
Kokkoris, M
Papadopoulos, CT
Tsabaris, C
机构
[1] Natl Tech Univ Athens, Dept Phys, Athens 15780, Greece
[2] Hellen Ctr Marine Res, GR-19013 Anavyssos, Greece
关键词
Monte Carlo simulations; GEANT4; code; monitoring radioactivity; gamma-spectrometry; efficiency calibration;
D O I
10.1016/j.apradiso.2005.07.011
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
The GEANT4 Monte Carlo code has been used to simulate gamma-ray spectra of natural radionuclides collected by a NaI scintillation detector immersed in seawater. The gamma-rays emitted from the decay of K-40, and the series of Th-232 and U-238, were used to describe the radioactive water source around the NaI crystal. The simulated gamma-ray spectra were compared with real data recorded in situ by a newly constructed NaI spectrometer and were found to be in good agreement. The NaI spectrometer was calibrated in the laboratory in a water tank, before its deployment in seawater. Activity concentrations were deduced from the gamma-ray spectra and discussed in comparison with results from the literature. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:116 / 123
页数:8
相关论文
共 50 条
  • [31] X-ray spectra and quality parameters from Monte Carlo simulation and analytical filters
    Salehi, Z.
    Ali, N. K. Ya
    Yusoff, A. L.
    APPLIED RADIATION AND ISOTOPES, 2012, 70 (11) : 2586 - 2589
  • [32] MONTE-CARLO SIMULATION OF GAMMA-RAY SPECTRA FROM SEMICONDUCTOR-DETECTORS
    OLSCHNER, F
    LUND, JC
    STERN, I
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) : 1176 - 1179
  • [33] Monte Carlo simulation of natural gamma ray spectrometry for underwater surfaces
    Maucec, M
    Hendriks, PHGM
    de Meijer, RJ
    ADVANCED MONTE CARLO FOR RADIATION PHYSICS, PARTICLE TRANSPORT SIMULATION AND APPLICATIONS, 2001, : 773 - 778
  • [34] Monte Carlo calculation of response functions to gamma-ray point sources for a spherical NaI(Tl) detector
    Yi, Chul-Young
    Hah, Suck-Ho
    APPLIED RADIATION AND ISOTOPES, 2012, 70 (09) : 2133 - 2136
  • [35] Characterisation of a well-type NaI(Tl) detector by means of a Monte Carlo simulation for radionuclide metrology application
    Heranudin
    Smith, M. L.
    van Wyngaardt, W. M.
    Guatelli, S.
    Li, E.
    Rosenfeld, A.
    APPLIED RADIATION AND ISOTOPES, 2021, 176
  • [36] Simulation of Energy Absorption Spectrum in NaI Crystal Detector for Multiple Gamma Energy Using Monte Carlo Method
    Wirawan, Rahadi
    Waris, Abdul
    Djamal, Mitra
    Handayani, Gunawan
    5TH ASIAN PHYSICS SYMPOSIUM (APS 2012), 2015, 1656
  • [37] MONTE CARLO SIMULATION OF AN ORGANIC SCINTILLATOR RESPONSE OF GAMMA-RAY SPECTRA
    MARTIN, IM
    BUIVAN, A
    VEDRENNE, G
    NUCLEAR INSTRUMENTS & METHODS, 1971, 95 (03): : 545 - &
  • [38] Monte Carlo simulation of prompt γ-ray spectra from depleted uranium under D-T neutron irradiation and electron recoil spectra in a liquid scintillator detector
    秦建国
    赖财锋
    刘荣
    朱通华
    张信威
    叶邦角
    Chinese Physics C, 2016, 40 (03) : 119 - 123
  • [39] Monte Carlo simulation of prompt γ-ray spectra from depleted uranium under D-T neutron irradiation and electron recoil spectra in a liquid scintillator detector
    Qin, Jian-Guo
    Lai, Cai-Feng
    Liu, Rong
    Zhu, Tong-Hua
    Zhang, Xin-Wei
    Ye, Bang-Jiao
    CHINESE PHYSICS C, 2016, 40 (03)
  • [40] Monte Carlo simulation of prompt γ-ray spectra from depleted uranium under D-T neutron irradiation and electron recoil spectra in a liquid scintillator detector
    秦建国
    赖财锋
    刘荣
    朱通华
    张信威
    叶邦角
    Chinese Physics C, 2016, (03) : 119 - 123