Flue gas purification and heat recovery: A biomass fired boiler supplied with an open absorption system

被引:73
|
作者
Westerlund, Lars [1 ]
Hermansson, Roger [1 ]
Fagerstrom, Jonathan [2 ]
机构
[1] Lulea Univ Technol, Div Energy Engn, S-97187 Lulea, Sweden
[2] Umea Univ, SE-90187 Umea, Sweden
关键词
Open absorption system; Particle reduction; Heat recovery; PILOT-PLANT; COMBUSTION; WOOD; APPLIANCES; REDUCTION; EMISSIONS;
D O I
10.1016/j.apenergy.2012.02.085
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A new technique for energy recovery combined with particle separation from flue gas has been tested in this project. A conventional small boiler for biofuel produces besides heat also particles to the environment through the flue gas. Decreasing the impact on the environment is desirable. Increased efficiency can be obtained if the temperature and water content of the flue gas can be further reduced. Installing an open absorption system in the heat production unit fulfils both these demands. An experimental unit has been built and tested in the last 2 years. The results show a reduction of particles in the flue gas by 33-44% compared to the ordinary system. At the same time the heat production from the unit increased by 40% when fired with wet biofuels. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:444 / 450
页数:7
相关论文
共 50 条
  • [21] Parametric analysis and design optimization of a fully open absorption heat pump for heat and water recovery of flue gas
    Ma, Yuxin
    Gao, Enyuan
    Zhang, Xiaosong
    Huang, Shifang
    APPLIED ENERGY, 2024, 375
  • [22] Use of waste heat recovery system for cleaning flue gas in a coal-fired power unit
    Szulc, Piotr
    Tietze, Tomasz
    PRZEMYSL CHEMICZNY, 2017, 96 (04): : 921 - 925
  • [23] A dynamic heat transfer model to estimate the flue gas temperature in the horizontal flue of the coal-fired utility boiler
    Zhang, Xiang
    Yuan, Jingqi
    Chen, Zhenxing
    Tian, Zhen
    Wang, Jingcheng
    APPLIED THERMAL ENGINEERING, 2018, 135 : 368 - 378
  • [24] Exergy analysis of the flue gas pre-dried lignite-fired power system based on the boiler with open pulverizing system
    Han, Xiaoqu
    Liu, Ming
    Wu, Kaili
    Chen, Weixiong
    Xiao, Feng
    Yan, Junjie
    ENERGY, 2016, 106 : 285 - 300
  • [25] Application of absorption heat pump and direct-contact total heat exchanger to advanced-recovery flue-gas waste heat for gas boiler
    Li Feng
    Lin, Duanmu
    Fu Lin
    Zhao Xiling
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2019, 25 (02) : 149 - 155
  • [26] Experimental investigation on vapor-pump equipped gas boiler for flue gas heat recovery
    Wei, Maolin
    Fu, Lin
    Zhang, Shigang
    Zhao, Xiling
    APPLIED THERMAL ENGINEERING, 2019, 147 : 371 - 379
  • [27] Thermodynamic and emission characteristics of a hydrogen-enriched natural gas-fired boiler integrated with external flue gas recirculation and waste heat recovery
    Wang, Tiantian
    Liu, Xuemin
    Zhang, Yang
    Zhang, Hai
    APPLIED ENERGY, 2024, 358
  • [28] Performance analysis of a novel double stage multifunctional open absorption heat pump system: An industrial moist flue gas heat recovery application
    Shahzad, Muhammad Kashif
    Ding, Yaqi
    Xuan, Yongmei
    Gao, Neng
    Chen, Guangming
    ENERGY CONVERSION AND MANAGEMENT, 2022, 254
  • [29] Corrosion in the Flue Gas Cleaning System of a Biomass-Fired Power Plant
    Montgomery M.
    Olesen R.E.
    Gensmann P.
    Journal of Failure Analysis and Prevention, 2017, 17 (2) : 195 - 204
  • [30] Waste heat and water recovery from natural gas boilers: Parametric analysis and optimization of a flue-gas-driven open absorption system
    Wang, Zhenying
    Zhang, Xiaoyue
    Han, Jianfeng
    Li, Zhen
    ENERGY CONVERSION AND MANAGEMENT, 2017, 154 : 526 - 537