Early Studies of a Transmission Mechanism for MR-Guided Interventions

被引:0
|
作者
Zhao, Haoran [1 ]
Liu, Xin [2 ]
Zaid, Habib M. [2 ]
Shah, Dipan J. [3 ]
Heffernan, Michael J. [4 ]
Becker, Aaron T. [1 ]
Tsekos, Nikolaos V. [2 ]
机构
[1] Univ Houston, Dept Elect & Comp Engn, Houston, TX 77004 USA
[2] Univ Houston, Dept Comp Sci, Houston, TX 77204 USA
[3] Methodist DeBakey Heart & Vasc Ctr, Cardiovasc MRI Lab, Houston, TX USA
[4] GuidaBot LLC, Houston, TX USA
来源
2017 IEEE 17TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOENGINEERING (BIBE) | 2017年
基金
美国国家科学基金会;
关键词
Solid media transmission; MR compatible; Robotic Actuator; COMPATIBLE ROBOTIC SYSTEM; MAGNETIC-RESONANCE; BRACHYTHERAPY; MOTION;
D O I
10.1109/BIBE.2017.00082
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Magnetic resonance imaging (MRI)-guided, manipulator-assisted interventions have the potential to improve patient outcomes. This work presents a force transmission mechanism, called solid-media transmission (SMT), for actuating manipulators inside MRI scanners. The SMT mechanism is based on conduits filled with spheres and spacers made of a nonmagnetic, nonconductive material that forms a backbone for bidirectional transmission. Early modeling and experimental studies assessed SMT and identified limitations and improvements. Simulations demonstrated the detrimental role of friction, which can be alleviated with a choice of low friction material and long spacers. However, the length of spacer is limited by the desired bending of the conduit. A closed-loop control law was implemented to drive the SMT. The 3rd order system fit ratio is 92.3%. A 1-m long SMT was experimentally tested under this closed-loop controller with heuristically set parameters using a customized benchtop setup. For commanded displacements of 1 to 50 mm, the SMT-actuated 1 degree of freedom stage exhibited sub-millimeter accuracy, which ranged from 0.109 +/- 0.057 mm to 0.045 +/- 0.029 mm depending on the commanded displacement. However, such accuracy required long control times inversely proportional to displacement ranging from 7.56 +/- 1.85s to 2.53 +/- 0.11s. This was attributed to friction as well as backlash which is due to suboptimal packing of the media. In MR studies, a 4-m long SMT-actuated 1 DoF manipulator was powered by a servo motor located inside the scanner room but outside the 5 Gauss line of the magnet. With shielding and filtering, the SNR of MR images during the operation of the servo motor and SMT-actuation was found to be 89 +/- 9% of the control case.
引用
收藏
页码:450 / 456
页数:7
相关论文
共 50 条
  • [41] Wireless mobile technology to improve workflow and feasibility of MR-guided percutaneous interventions
    Rube, Martin A.
    Holbrook, Andrew B.
    Cox, Benjamin F.
    Buciuc, Razvan
    Melzer, Andreas
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2015, 10 (05) : 665 - 676
  • [42] Wireless mobile technology to improve workflow and feasibility of MR-guided percutaneous interventions
    Martin A. Rube
    Andrew B. Holbrook
    Benjamin F. Cox
    Razvan Buciuc
    Andreas Melzer
    International Journal of Computer Assisted Radiology and Surgery, 2015, 10 : 665 - 676
  • [43] Towards MR-guided EP interventions using an RF-safe approach
    Sascha Krueger
    Oliver Lips
    Bernd David
    Daniel Wirtz
    Steffen Weiss
    Steen F Pedersen
    Dennis Caulfield
    Julian Bostock
    Reza Razavi
    Tobias Schaeffter
    Journal of Cardiovascular Magnetic Resonance, 11 (Suppl 1)
  • [44] Robotic assist for MR-guided surgery using leverage and parallelepiped mechanism
    Koseki, Y
    Chinzei, K
    Koyachi, N
    Arai, T
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2000, 2000, 1935 : 940 - 948
  • [45] An MR-compatible stereoscopic in-room 3D display for MR-guided interventions
    Brunner, Alexander
    Groebner, Jens
    Umathum, Reiner
    Maier, Florian
    Semmler, Wolfhard
    Bock, Michael
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2014, 27 (04) : 277 - 282
  • [46] An MR-compatible stereoscopic in-room 3D display for MR-guided interventions
    Alexander Brunner
    Jens Groebner
    Reiner Umathum
    Florian Maier
    Wolfhard Semmler
    Michael Bock
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2014, 27 : 277 - 282
  • [47] MR-guided balloon angioplasty: In vitro demonstration of the potential of MR for guiding, monitoring, and evaluating endovascular interventions
    Smits, HF
    Bakker, CJ
    Bos, C
    Hurtak, WF
    VanVaals, JJ
    Mali, WP
    RADIOLOGY, 1997, 205 : 1554 - 1554
  • [48] Early outcomes of MR-guided SBRT for patients with recurrent pancreatic adenocarcinoma
    Poiset, Spencer J.
    Shah, Sophia
    Cappelli, Louis
    Anne, Pramila
    Mooney, Karen E.
    Werner-Wasik, Maria
    Laufer, Talya S.
    Posey, James A.
    Lin, Daniel
    Mallick, Atrayee Basu
    Lavu, Harish
    Bashir, Babar
    Yeo, Charles J.
    Mueller, Adam C.
    RADIATION ONCOLOGY, 2024, 19 (01)
  • [49] Early Outcomes of MR-Guided SBRT for Patients with Recurrent Pancreatic Adenocarcinoma
    Poiset, S. J.
    Laufer, T.
    Anne, P. R.
    Mooney, K.
    Werner-Wasik, M.
    Posey, J. A.
    Bashir, B.
    Lin, D.
    Basu-Mallick, A.
    Lavu, H.
    Yeo, C. J.
    Mueller, A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2023, 117 (02): : E333 - E334
  • [50] Real-time inversion recovery for infarct visualization during MR-guided interventions
    Adrienne E Campbell-Washburn
    Toby Rogers
    Jonathan R Mazal
    Michael S Hansen
    Robert J Lederman
    Anthony Z Faranesh
    Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)