Quality comparison between three-dimensional T2-weighted SPACE and two-dimensional T2-weighted turbo spin echo magnetic resonance images for the brachytherapy planning evaluation of prostate and periprostatic anatomy

被引:8
|
作者
Bathala, Tharakeswara K. [1 ]
Venkatesan, Aradhana M. [1 ]
Ma, Jingfei [2 ]
Bhosale, Priyadarshini [1 ]
Wei, Wei [5 ]
Kudchadker, Rajat J. [3 ]
Wang, Jihong [3 ]
Anscher, Mitchell S. [4 ]
Tang, Chad [4 ]
Bruno, Teresa L. [4 ]
Frank, Steven J. [4 ]
Szklaruk, Janio [1 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Abdominal Imaging, Houston, TX 77030 USA
[2] Univ Texas MD Anderson Canc Ctr, Dept Imaging Phys, Houston, TX 77030 USA
[3] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[4] Univ Texas MD Anderson Canc Ctr, Dept Radiat Oncol, Houston, TX 77030 USA
[5] Cleveland Clin, Canc Biostat Sect, Taussig Canc Inst, Cleveland, OH 44106 USA
基金
美国国家卫生研究院;
关键词
Prostate brachytherapy; Low-dose-rate brachytherapy; Prostate magnetic resonance imaging; 3D SPACE sequence; 2D TSE sequence; 3D; 2D; MRI; SEQUENCE; EXPERIENCE;
D O I
10.1016/j.brachy.2020.04.001
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
PURPOSE: The purpose of this study was to compare an isotropic three-dimensional (3D) T2-weighted sequence sampling perfection with application-optimized contrasts by using flip angle evolution (SPACE) with an axial two-dimensional T2-weighted turbo spin echo (TSE) sequence with regard to overall image quality and the delineation of normal prostate and periprostatic anatomy for low-dose-rate prostate cancer brachytherapy planning evaluation. METHODS AND MATERIALS: Patients (n = 69) with prostate cancer who had pelvic magnetic resonance imaging (MRI) for low-dose-rate brachytherapy treatment planning were included. Three radiologists independently assessed the visibility of nine anatomic structures on each sequence by using a 5-point scale and overall image quality by using a 4-point scale. The significance of the differences in diagnostic performance was tested with a Wilcoxon signed rank test. RESULTS: No significant intersequence differences were found for most (7/9) anatomical structures and overall image quality. The mean scores for visibility of anatomical structures on the 3D SPACE and 2D TSE sequences, respectively, were as follows: the zonal anatomy (3.7; 3.9, p = 0.05), prostate capsule (3.9; 4.0, p = 0.08), neurovascular bundle (2.9; 2.9, p = 0.9), rectoprostatic angle (3.8; 3.8, p = 0.35), rectum (4.2; 4.3, p = 0.26), urethra (3.8; 3.9, p = 0.12), urinary bladder (4.6; 4.6, p = 0.61), and overall image quality (2.9; 2.9, p = 0.33). 3D SPACE was superior for delineation of the genitourinary diaphragm (3.8; 3.6, p = 0.003), whereas 2D TSE was superior for delineation of the seminal vesicles (3.5; 4.0, p < 0.0001). CONCLUSIONS: Anatomic delineation of the prostatic and periprostatic anatomy provided by the 3D SPACE sequence is as robust in quality as that provided by a conventional 2D TSE sequence with superior delineation of the genitourinary diaphragm. For MRI-based brachytherapy treatment planning, the 3D SPACE sequence with subcentimeter isotropic resolution can replace the 2D TSE sequence and be incorporated into standard MRI protocols. Published by Elsevier Inc. on behalf of American Brachytherapy Society.
引用
收藏
页码:484 / 490
页数:7
相关论文
共 50 条
  • [31] Comparison of conventional fast spin echo, single-shot two-dimensional and three-dimensional half-fourier RARE for T2-weighted female pelvic imaging
    Sugimura, H
    Yamaguchi, K
    Furukoji, E
    Tamura, S
    Sakae, T
    Koga, H
    Machida, Y
    Kitane, S
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 19 (03) : 349 - 355
  • [32] Magnetic resonance imaging of hyaline cartilage defects at 1.5T and 3.0T: Comparison of medium T2-weighted fast spin echo, T1-weighted two-dimensional and three-dimensional gradient echo pulse sequences (vol 46, pg 67, 2005)
    Fischbach, F
    Bruhn, H
    Unterhauser, F
    Ricke, J
    Wieners, G
    Felix, R
    Weiler, A
    Schroder, RJ
    ACTA RADIOLOGICA, 2005, 46 (02) : 218 - 218
  • [33] T2-weighted three-dimensional fast spin-echo MR in inflammatory peripheral facial nerve palsy
    Sartoretti-Schefer, S
    Kollias, S
    Wichmann, W
    Valavanis, A
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1998, 19 (03) : 491 - 495
  • [34] Comparison between T2-weighted two-dimensional and three-dimensional fast spin-echo MRI sequences for characterizing thoracolumbar intervertebral disc disease in small-breed dogs
    Lee, Suhyeon
    Hwang, Jeongyeon
    Ko, Jaeeun
    Jeong, Jeongyun
    Eom, Kidong
    Kim, Jaehwan
    VETERINARY RADIOLOGY & ULTRASOUND, 2022, 63 (02) : 216 - 223
  • [35] Semicircular canal dehiscence: comparison of T2-weighted turbo spin-echo MRI and CT
    G. A. Krombach
    T. Schmitz-Rode
    P. Haage
    E. DiMartino
    A. Prescher
    S. Kinzel
    R. W. Günther
    Neuroradiology, 2004, 46 : 326 - 331
  • [36] Semicircular canal dehiscence:: comparison of T2-weighted turbo spin-echo MRI and CT
    Krombach, GA
    Schmitz-Rode, T
    Haage, P
    DiMartino, E
    Prescher, A
    Kinzel, S
    Günther, RW
    NEURORADIOLOGY, 2004, 46 (04) : 326 - 331
  • [37] Comparison of multishot turbo spin echo and HASTE sequences for T2-weighted MRI of liver lesions
    Yu, JS
    Kim, KW
    Kim, YH
    Jeong, EK
    Chien, D
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (05): : 1079 - 1084
  • [38] T2-weighted fast spin-echo magnetic resonance imaging of extraocular muscles
    Demer, Joseph L.
    Dushyanth, Anita
    JOURNAL OF AAPOS, 2011, 15 (01): : 17 - 23
  • [39] Endometrial cancer: preoperative staging using three-dimensional T2-weighted turbo spin-echo and diffusion-weighted MR imaging at 3.0 T: a prospective comparative study
    Masatoshi Hori
    Tonsok Kim
    Hiromitsu Onishi
    Izumi Imaoka
    Yuki Kagawa
    Takamichi Murakami
    Atsushi Nakamoto
    Takashi Ueguchi
    Mitsuaki Tatsumi
    Takayuki Enomoto
    Tadashi Kimura
    Noriyuki Tomiyama
    European Radiology, 2013, 23 : 2296 - 2305
  • [40] Endometrial cancer: preoperative staging using three-dimensional T2-weighted turbo spin-echo and diffusion-weighted MR imaging at 3.0 T: a prospective comparative study
    Hori, Masatoshi
    Kim, Tonsok
    Onishi, Hiromitsu
    Imaoka, Izumi
    Kagawa, Yuki
    Murakami, Takamichi
    Nakamoto, Atsushi
    Ueguchi, Takashi
    Tatsumi, Mitsuaki
    Enomoto, Takayuki
    Kimura, Tadashi
    Tomiyama, Noriyuki
    EUROPEAN RADIOLOGY, 2013, 23 (08) : 2296 - 2305