Quality comparison between three-dimensional T2-weighted SPACE and two-dimensional T2-weighted turbo spin echo magnetic resonance images for the brachytherapy planning evaluation of prostate and periprostatic anatomy

被引:8
|
作者
Bathala, Tharakeswara K. [1 ]
Venkatesan, Aradhana M. [1 ]
Ma, Jingfei [2 ]
Bhosale, Priyadarshini [1 ]
Wei, Wei [5 ]
Kudchadker, Rajat J. [3 ]
Wang, Jihong [3 ]
Anscher, Mitchell S. [4 ]
Tang, Chad [4 ]
Bruno, Teresa L. [4 ]
Frank, Steven J. [4 ]
Szklaruk, Janio [1 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Abdominal Imaging, Houston, TX 77030 USA
[2] Univ Texas MD Anderson Canc Ctr, Dept Imaging Phys, Houston, TX 77030 USA
[3] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[4] Univ Texas MD Anderson Canc Ctr, Dept Radiat Oncol, Houston, TX 77030 USA
[5] Cleveland Clin, Canc Biostat Sect, Taussig Canc Inst, Cleveland, OH 44106 USA
基金
美国国家卫生研究院;
关键词
Prostate brachytherapy; Low-dose-rate brachytherapy; Prostate magnetic resonance imaging; 3D SPACE sequence; 2D TSE sequence; 3D; 2D; MRI; SEQUENCE; EXPERIENCE;
D O I
10.1016/j.brachy.2020.04.001
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
PURPOSE: The purpose of this study was to compare an isotropic three-dimensional (3D) T2-weighted sequence sampling perfection with application-optimized contrasts by using flip angle evolution (SPACE) with an axial two-dimensional T2-weighted turbo spin echo (TSE) sequence with regard to overall image quality and the delineation of normal prostate and periprostatic anatomy for low-dose-rate prostate cancer brachytherapy planning evaluation. METHODS AND MATERIALS: Patients (n = 69) with prostate cancer who had pelvic magnetic resonance imaging (MRI) for low-dose-rate brachytherapy treatment planning were included. Three radiologists independently assessed the visibility of nine anatomic structures on each sequence by using a 5-point scale and overall image quality by using a 4-point scale. The significance of the differences in diagnostic performance was tested with a Wilcoxon signed rank test. RESULTS: No significant intersequence differences were found for most (7/9) anatomical structures and overall image quality. The mean scores for visibility of anatomical structures on the 3D SPACE and 2D TSE sequences, respectively, were as follows: the zonal anatomy (3.7; 3.9, p = 0.05), prostate capsule (3.9; 4.0, p = 0.08), neurovascular bundle (2.9; 2.9, p = 0.9), rectoprostatic angle (3.8; 3.8, p = 0.35), rectum (4.2; 4.3, p = 0.26), urethra (3.8; 3.9, p = 0.12), urinary bladder (4.6; 4.6, p = 0.61), and overall image quality (2.9; 2.9, p = 0.33). 3D SPACE was superior for delineation of the genitourinary diaphragm (3.8; 3.6, p = 0.003), whereas 2D TSE was superior for delineation of the seminal vesicles (3.5; 4.0, p < 0.0001). CONCLUSIONS: Anatomic delineation of the prostatic and periprostatic anatomy provided by the 3D SPACE sequence is as robust in quality as that provided by a conventional 2D TSE sequence with superior delineation of the genitourinary diaphragm. For MRI-based brachytherapy treatment planning, the 3D SPACE sequence with subcentimeter isotropic resolution can replace the 2D TSE sequence and be incorporated into standard MRI protocols. Published by Elsevier Inc. on behalf of American Brachytherapy Society.
引用
收藏
页码:484 / 490
页数:7
相关论文
共 50 条
  • [1] Comparison of oblique coronal images in knee of three-dimensional isotropic T2-weighted turbo spin echo MRI versus two-dimensional fast spin echo T2-weighted sequences for evaluation of posterior cruciate ligament injury
    Park, Hee J.
    Lee, So Y.
    Choi, Seon H.
    Ahn, Jin H.
    Park, Se J.
    Park, Jai H.
    Kim, Eugene
    BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1067):
  • [2] Three-dimensional isotropic T2-weighted cervical MRI at 3 T: Comparison with two-dimensional T2-weighted sequences
    Kwon, J. W.
    Yoon, Y. C.
    Choi, S. -H.
    CLINICAL RADIOLOGY, 2012, 67 (02) : 106 - 113
  • [3] T2-weighted three-dimensional turbo spin-echo MR of intracranial aneurysms
    Rubinstein, D
    Sandberg, EJ
    Breeze, RE
    Sheppard, SK
    Perkins, TG
    CajadeLaw, AG
    Simon, JH
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1997, 18 (10) : 1939 - 1943
  • [4] Evaluation of diagnostic value and T2-weighted three-dimensional isotropic turbo spin-echo (3D-SPACE) image quality in comparison with T2-weighted two-dimensional turbo spin-echo (2D-TSE) sequences in lumbar spine MR imaging
    Hossein, Jomleh
    Fariborz, Faeghi
    Mehrnaz, Rasteh
    Babak, Rafiei
    EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2019, 6 : 36 - 41
  • [5] Value of three-dimensional T2-weighted turbo spin-echo imaging with tissue-specific variable refocusing flip angle for 3-T magnetic resonance imaging of prostate cancer: comparison with conventional two- and three-dimensional T2-weighted turbo spin-echo imaging
    Utaru Tanaka
    Yoshiko Ueno
    Yukiko Morinaga
    Hideaki Miyake
    Katsusuke Kyotani
    Yu Ueda
    Kazuhiro Kitajima
    Keitaro Sofue
    Yuko Suenaga
    Kazuro Sugimura
    Satoru Takahashi
    Japanese Journal of Radiology, 2017, 35 : 707 - 717
  • [6] Value of three-dimensional T2-weighted turbo spin-echo imaging with tissue-specific variable refocusing flip angle for 3-T magnetic resonance imaging of prostate cancer: comparison with conventional two- and three-dimensional T2-weighted turbo spin-echo imaging
    Tanaka, Utaru
    Ueno, Yoshiko
    Morinaga, Yukiko
    Miyake, Hideaki
    Kyotani, Katsusuke
    Ueda, Yu
    Kitajima, Kazuhiro
    Sofue, Keitaro
    Suenaga, Yuko
    Sugimura, Kazuro
    Takahashi, Satoru
    JAPANESE JOURNAL OF RADIOLOGY, 2017, 35 (12) : 707 - 717
  • [7] Three-dimensional isotropic T2-weighted fast spin-echo (VISTA) ankle MRI versus two-dimensional fast spin-echo T2-weighted sequences for the evaluation of anterior talofibular ligament injury
    Park, H. J.
    Lee, S. Y.
    Park, N. H.
    Rho, M. H.
    Chung, E. C.
    Park, J. H.
    Park, S. J.
    CLINICAL RADIOLOGY, 2016, 71 (04) : 349 - 355
  • [8] Three-dimensional isotropic T2-weighted fast spin-echo (VISTA) knee MRI at 3.0T in the evaluation of the anterior cruciate ligament injury with additional views: comparison with two-dimensional fast spin-echo T2-weighted sequences
    Park, Hee Jin
    Lee, So Yeon
    Park, Noh Hyuck
    Ahn, Jin Hwan
    Chung, Eun Chul
    Kim, Sung Jun
    Cha, Jang Gyu
    ACTA RADIOLOGICA, 2016, 57 (11) : 1372 - 1379
  • [9] Magnetic resonance imaging of hyaline cartilage defects at 1.5T and 3.0T:: comparison of medium T2-weighted fast spin echo, T1-weighted two-dimensional and three-dimensional gradient echo pulse sequences
    Fischbach, F
    Bruhn, H
    Unterhauser, F
    Ricke, J
    Wieners, G
    Felix, R
    Weiler, A
    Schröder, RJ
    ACTA RADIOLOGICA, 2005, 46 (01) : 67 - 73
  • [10] Preoperative 3 T MR imaging of rectal cancer:: Local staging accuracy using a two-dimensional and three-dimensional T2-weighted turbo spin echo sequence
    Fuetterer, Jurgen J.
    Yakar, Derya
    Strijk, Simon P.
    Barentsz, Jelle O.
    EUROPEAN JOURNAL OF RADIOLOGY, 2008, 65 (01) : 66 - 71