Simultaneous, accurate measurement of the 3D position and orientation of single molecules

被引:151
|
作者
Backlund, Mikael P. [1 ]
Lew, Matthew D. [1 ,2 ]
Backer, Adam S. [1 ,3 ]
Sahl, Steffen J. [1 ]
Grover, Ginni [4 ]
Agrawal, Anurag [4 ]
Piestun, Rafael [4 ]
Moerner, W. E. [1 ]
机构
[1] Stanford Univ, Dept Chem, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Elect Engn, Stanford, CA 94305 USA
[3] Stanford Univ, Inst Computat & Math Engn, Stanford, CA 94305 USA
[4] Univ Colorado, Dept Elect Comp & Energy Engn, Boulder, CO 80309 USA
基金
美国国家科学基金会;
关键词
OPTICAL RECONSTRUCTION MICROSCOPY; POINT-SPREAD FUNCTION; SUPERRESOLUTION MICROSCOPY; FLUORESCENCE MICROSCOPY; DIFFRACTION-LIMIT; LOCALIZATION; SPECTROSCOPY; TRACKING; EMITTERS; MOTORS;
D O I
10.1073/pnas.1216687109
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Recently, single molecule-based superresolution fluorescence microscopy has surpassed the diffraction limit to improve resolution to the order of 20 nm or better. These methods typically use image fitting that assumes an isotropic emission pattern from the single emitters as well as control of the emitter concentration. However, anisotropic single-molecule emission patterns arise from the transition dipole when it is rotationally immobile, depending highly on the molecule's 3D orientation and z position. Failure to account for this fact can lead to significant lateral (x, y) mislocalizations (up to similar to 50-200 nm). This systematic error can cause distortions in the reconstructed images, which can translate into degraded resolution. Using parameters uniquely inherent in the double-lobed nature of the Double-Helix Point Spread Function, we account for such mislocalizations and simultaneously measure 3D molecular orientation and 3D position. Mislocalizations during an axial scan of a single molecule manifest themselves as an apparent lateral shift in its position, which causes the standard deviation (SD) of its lateral position to appear larger than the SD expected from photon shot noise. By correcting each localization based on an estimated orientation, we are able to improve SDs in lateral localization from similar to 2x worse than photon-limited precision (48 vs. 25 nm) to within 5 nm of photon-limited precision. Furthermore, by averaging many estimations of orientation over different depths, we are able to improve from a lateral SD of 116 (similar to 4x worse than the photon-limited precision; 28 nm) to 34 nm (within 6 nm of the photon limit).
引用
收藏
页码:19087 / 19092
页数:6
相关论文
共 50 条
  • [21] Accurate 3D measurement using a structured light system
    Valkenburg, RJ
    McIvor, AM
    IMAGE AND VISION COMPUTING, 1998, 16 (02) : 99 - 110
  • [22] Study on accurate 3D magnetic field measurement system
    Chen Dixiang
    Pan Mengchun
    Luo Feilu
    ICEMI 2007: PROCEEDINGS OF 2007 8TH INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS, VOL II, 2007, : 680 - 683
  • [23] 3D Joint Speaker Position and Orientation Tracking with Particle Filters
    Segura, Carlos
    Hernando, Javier
    SENSORS, 2014, 14 (02) : 2259 - 2279
  • [24] Fusion of Inertial and Magnetic Sensors for 3D Position and Orientation Estimation
    Tadayon, P.
    Felderhoff, T.
    Knopp, A.
    Staude, G.
    2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 3362 - 3365
  • [25] Accurate 3D measurement using optical depth information
    Traumann, A.
    Daneshmand, M.
    Escalera, S.
    Anbarjafari, G.
    ELECTRONICS LETTERS, 2015, 51 (18) : 1420 - 1422
  • [26] Accurate measurement of 3D coordinate of an object with subpixel technique
    Yu, QF
    Zhang, DS
    Lei, ZH
    Quan, TH
    INFORMATION INTELLIGENCE AND SYSTEMS, VOLS 1-4, 1996, : 484 - 486
  • [27] HIGHLY ACCURATE 3-D POSITION MEASUREMENT AND NONLINEAR COORDINATE TRANSFORMATION
    NARUSE, H
    NOMURA, Y
    SAGARA, M
    VISUAL COMMUNICATIONS AND IMAGE PROCESSING IV, PTS 1-3, 1989, 1199 : 667 - 676
  • [28] Local position measurement system for fast and accurate 3-D monitoring
    Fischer, A
    Pracherstorfer, G
    Stelzer, A
    Söser, A
    NONDESTRUCTIVE DETECTION AND MEASUREMENT FOR HOMELAND SECURITY, 2003, 5048 : 128 - 135
  • [29] Measurement of 3D Spreader Position for Automatic Landing System
    Lee, Jung Jae
    Nam, Gi Gun
    Lee, Bong Ki
    Lee, Jang Myung
    IECON 2004: 30TH ANNUAL CONFERENCE OF IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOL 3, 2004, : 3008 - 3013
  • [30] 3D nonholonomic source seeking without position measurement
    Cochran, Jennie
    Ghods, Nima
    Krstic, Miroslav
    2008 AMERICAN CONTROL CONFERENCE, VOLS 1-12, 2008, : 3518 - 3523