Simultaneous, accurate measurement of the 3D position and orientation of single molecules

被引:151
|
作者
Backlund, Mikael P. [1 ]
Lew, Matthew D. [1 ,2 ]
Backer, Adam S. [1 ,3 ]
Sahl, Steffen J. [1 ]
Grover, Ginni [4 ]
Agrawal, Anurag [4 ]
Piestun, Rafael [4 ]
Moerner, W. E. [1 ]
机构
[1] Stanford Univ, Dept Chem, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Elect Engn, Stanford, CA 94305 USA
[3] Stanford Univ, Inst Computat & Math Engn, Stanford, CA 94305 USA
[4] Univ Colorado, Dept Elect Comp & Energy Engn, Boulder, CO 80309 USA
基金
美国国家科学基金会;
关键词
OPTICAL RECONSTRUCTION MICROSCOPY; POINT-SPREAD FUNCTION; SUPERRESOLUTION MICROSCOPY; FLUORESCENCE MICROSCOPY; DIFFRACTION-LIMIT; LOCALIZATION; SPECTROSCOPY; TRACKING; EMITTERS; MOTORS;
D O I
10.1073/pnas.1216687109
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Recently, single molecule-based superresolution fluorescence microscopy has surpassed the diffraction limit to improve resolution to the order of 20 nm or better. These methods typically use image fitting that assumes an isotropic emission pattern from the single emitters as well as control of the emitter concentration. However, anisotropic single-molecule emission patterns arise from the transition dipole when it is rotationally immobile, depending highly on the molecule's 3D orientation and z position. Failure to account for this fact can lead to significant lateral (x, y) mislocalizations (up to similar to 50-200 nm). This systematic error can cause distortions in the reconstructed images, which can translate into degraded resolution. Using parameters uniquely inherent in the double-lobed nature of the Double-Helix Point Spread Function, we account for such mislocalizations and simultaneously measure 3D molecular orientation and 3D position. Mislocalizations during an axial scan of a single molecule manifest themselves as an apparent lateral shift in its position, which causes the standard deviation (SD) of its lateral position to appear larger than the SD expected from photon shot noise. By correcting each localization based on an estimated orientation, we are able to improve SDs in lateral localization from similar to 2x worse than photon-limited precision (48 vs. 25 nm) to within 5 nm of photon-limited precision. Furthermore, by averaging many estimations of orientation over different depths, we are able to improve from a lateral SD of 116 (similar to 4x worse than the photon-limited precision; 28 nm) to 34 nm (within 6 nm of the photon limit).
引用
收藏
页码:19087 / 19092
页数:6
相关论文
共 50 条
  • [1] Simultaneous measurement of emission color and 3D position of single molecules
    Smith, Carlas
    Huisman, Max
    Siemons, Marijn
    Gruenwald, David
    Stallinga, Sjoerd
    OPTICS EXPRESS, 2016, 24 (05): : 4996 - 5013
  • [2] Combining deep learning approaches and point spread function engineering for simultaneous 3D position and 3D orientation measurements of fluorescent single molecules
    Jouchet, Pierre
    Roy, Anish R.
    Moerner, W. E.
    OPTICS COMMUNICATIONS, 2023, 542
  • [3] An Accurate Technique for Simultaneous Measurement of 3D Position and Velocity of a Moving Object Using a Single Ultrasonic Receiver Unit
    Nakamura, Shigeki
    Sato, Tomohiko
    Sugimoto, Masanori
    Hashizume, Hiromichi
    2010 INTERNATIONAL CONFERENCE ON INDOOR POSITIONING AND INDOOR NAVIGATION, 2010,
  • [4] "MEMSEye" for Optical 3D Position and Orientation Measurement
    Milanovic, V.
    Siu, N.
    Kasturi, A.
    Radojicic, M.
    Su, Y.
    MOEMS AND MINIATURIZED SYSTEMS X, 2011, 7930
  • [5] MEASUREMENT OF 3D VERTEBRAL BODY POSITION AND ORIENTATION USING SINGLE PLANE FLUOROSCOPY
    Conrad, Bryan P.
    Banks, Scott A.
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE, 2010, 2010, : 847 - 848
  • [6] Measuring the 3D Position and Orientation of Single Molecules Simultaneously and Accurately with the Double Helix Microscope
    Lew, Matthew D.
    Backlund, Mikael P.
    Backer, Adam S.
    Sahl, Steffen J.
    Grover, Ginni
    Agrawal, Anurag
    Piestun, Rafael
    Moerner, W. E.
    2013 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2013,
  • [7] Quantitative determination of the 3D dipole orientation of single molecules
    Débarre, A
    Jaffiol, R
    Julien, C
    Nutarelli, D
    Richard, A
    Tchénio, P
    Chaput, F
    Boilot, JP
    EUROPEAN PHYSICAL JOURNAL D, 2004, 28 (01): : 67 - 77
  • [8] Quantitative determination of the 3D dipole orientation of single molecules
    A. Débarre
    R. Jaffiol
    C. Julien
    D. Nutarelli
    A. Richard
    P. Tchénio
    F. Chaput
    J.-P. Boilot
    The European Physical Journal D - Atomic, Molecular, Optical and Plasma Physics, 2004, 28 : 67 - 77
  • [9] 3D imaging with large range dynamics and simultaneous accurate speed measurement
    Feneyrou, Patrick
    Martin, Aude
    Dolfi, Daniel
    Payot, Etienne
    APPLIED OPTICS, 2024, 63 (20) : 5387 - 5394
  • [10] Accurate superresolution microscopy of the 3D orientations and 3D locations of single molecules within lipid membranes and biomolecular condensates
    Wu, Tingting
    Lu, Jin
    King, Matthew R.
    Pappu, Rohit V.
    Lew, Matthew D.
    BIOPHYSICAL JOURNAL, 2022, 121 (03) : 142 - 142